Heatiator BH60 manual Installation-Plumbing, Domestic HOT Water Zone

Page 14

Installation-Plumbing

TYPICAL BOILER HOT WATER PIPING SHOWING AIR REMOVAL SYSTEM, PROVISIONS FOR THE EXPANSION OF WATER AND THE AUTOMATIC COLD WATER SUPPLY. ALSO SHOWN BUT NOT NECESSARILY NEEDED IS THE BOILER BYPASS LINE.THE NECESSITY OF THIS LINE WILL BE DETERMINED BY THE INSTALLING CERTIFIED PLUMBER OR HVAC CONTRACTOR.

NOTE: ALWAYS REFER TO THE INDIVIDUAL COMPONENTS RECOMMENDED INSTALLATION INSTRUCTIONS FOR THE PROPER MOUNTING POSITION AND LOCATION WITHIN THE PIPING SYSTEM.

NOTICE: When installing with the Atmospheric Conversion, all of the pressurized system components shown are not necessary. Air vents or bleeders should be removed from the plumbing system to prevent air from entering the lines. Control dipswitch #6 must be “ON”.

SYSTEM SUPPLY 3/4"

AIR VENT

** THERMOMETER

AIR SCOOP

SYSTEM SUPPLY 3/4"

*3/4" NPT MALE PLUG

 

 

 

 

SHUT-OFF

* AUTOMATIC AIR VENT

 

 

 

VALVE

 

 

 

 

* TEMP/PRESSURE GAUGE

* PRESSURE RELIEF VALVE

UNION

BYPASS

 

VALVE

PIPE TO WITHIN 6" OF THE FLOOR OR A FLOOR DRAIN

UNION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE REDUCING

CHECK VALVE (OR

SHUT-OFF

 

 

 

VALVE (PRV) OR

BACKFLOW

VALVE

 

 

 

COMBINATION PRV AND

PREVENTER IF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELIEF VALVE

REQUIRED)

 

 

 

 

EXPANSION TANK

 

 

 

 

 

 

 

(DIAPHRAGM TYPE)

 

 

 

 

 

 

 

3/4" BOILER BYPASS LINE (IF REQUIRED)

** THERMOMETER

SYSTEM RETURN 3/4"

COLD

WATER SUPPLY 1/2"

*BOILER DRAIN, 3/4" NPT MALE X

3/4" HOSE

SHUT-OFF VALVE

NOTE: Cold return water temperature (Sustained temperatures below 140 degrees

 

Fahrenheit) will lead to condensation or moisture in the firebox. This moisture can

 

lead to creosote formation. To help minimize moisture and creosote, it is strongly

* ITEMS SUPPLIED

recommended that some method of temperature balance is incorporated into the

** OPTIONAL

return system.

 

EXAMPLE OF A TYPICAL MULTI-ZONE HEATING SYSTEM WITH BOILER BYPASS AND INDIRECT

 

NOTE: ALWAYS REFER TO THE INDIVIDUAL COMPONENTS

 

RECOMMENDED INSTALLATION INSTRUCTIONS FOR THE PROPER

DOMESTIC HOT WATER ZONE

 

 

 

 

 

 

MOUNTING POSITION AND LOCATION WITHIN THE PIPING SYSTEM.

NOTICE: When installing with the Atmospheric Conversion, all of the pressurized

 

 

 

 

system components shown are not necessary. Air vents or bleeders should be

EXPANSION TANK, AIR REMOVAL AND COLD WATER SUPPLY

 

 

removed from the plumbing system to prevent air from entering the lines.

 

 

 

 

Control dipswitch #6 must be “ON”.

 

 

 

** THERMOMETER

 

 

 

 

 

 

 

 

 

 

BALANCING VALVE

 

SYSTEM SUPPLY 3/4"

 

 

CHECK VALVE

 

 

 

 

 

 

SYSTEM SUPPLY 3/4"

 

* AUTOMATIC AIR VENT

 

 

COLD HOT

BOILER BYPASS CAN ALSO BE DONE WITH A 3-WAY

 

 

 

* TEMP/PRESSURE

 

 

 

MIXING VALVE AND CAN BE CONTROLLED MANUALLY

SHUT-OFF VALVE

 

OR WITH AN AUTOMATIC ACTUATING MOTOR. IF SO,

GAUGE

 

 

DOMESTIC HOT

THE TWO BALANCING VALVES ARE NOT NEEDED

 

 

CIRCULATOR

 

 

* PRESSURE RELIEF VALVE

 

WATER STORAGE

 

 

 

 

 

 

 

 

 

HEATER WITH

 

 

 

 

 

INTERNAL HEAT

 

 

 

UNION

 

EXCHANGER

BYPASS (BALANCING) VALVE BOILER WATER

SUPPLY WATER

 

 

 

 

 

 

 

 

 

 

RETURN WATER

* 3/4" NPT MALE PLUG

 

 

IN

 

 

PIPE TO WITHIN 6" OF THE FLOOR OR A

 

 

 

 

 

FLOOR DRAIN

 

 

 

 

 

 

 

 

OUT

** THERMOMETER

 

 

 

 

 

 

UNION

 

 

 

 

 

 

 

SHUT-OFF VALVE

CHECK VALVE

SYSTEM RETURN 3/4"

 

*BOILER DRAIN, 3/4" NPT MALE X 3/4" HOSE

NOTE: Cold return water temperature (Sustained temperatures below 140 degrees

 

Fahrenheit) will lead to condensation or moisture in the firebox. This moisture can

 

lead to creosote formation. To help minimize moisture and creosote, it is strongly

* ITEMS SUPPLIED

recommended that some method of temperature balance is incorporated into the

** OPTIONAL

return system.

 

14

Image 14
Contents Installation & Operating Manual Bio-Flow BH60 Pellet BoilerPage BH60 Parts Table of Contents Options Bulk Storage HopperBoiler Kit Materials Refer to InstallationPreparation For Installation Minimum non-combustible floor protection area Minimum Clearances To Combustible Materials Venting Requirements for Terminating the VentingVenting Vent PipeVentingti g Venting Into An Existing ChimneyVenting Installation Negative Pressure and Electrical Power Failure Outside AirInstallation-Plumbing Domestic HOT Water ZoneBoiler Existing Controls and Safety Devices areExtremely Important That this Boiler be Existing Boiler Example of Piping in Series withAN Existing Operational Boiler Associated Piping and Controls That shouldInstallingInstallationDuct/Air-PlumbingConditioning Dipswitch #6 must be on Example of a Typical Forced HOT AIR Heating System Installation With a Hot Air System Splice R1 RelayInstallation With a Hot Air System fan only capable R2 RelayWith a 2-wire hot air system Overheat Safety ZoneConnection with a wireless thermostat Blue VioletTest Draft Test ProcedureLow Draft Adjustment Pot High altitude kit #1-00-232059 DraftOperation Status light error messagesExplanation and Importance of the OverHeat Safety Zone Control Board Operation Pellet Boiler Outdoor Air Reset Operation Turn Mode Selector to OFF Clean Burnpot with scraperFlip the Igniter Switch up into the Auto position MAX. TempLighting a Fire Manually Type of FuelOperation Burnp ot MaintenanceCleanout cover Fines area Feeder cover FigOpen The Firebox Door Inner Refractory LiningAsh Removal Cleaning Firebox Baffle RemovalCombustion Blower Cleaning Boiler Must be OFF at the circuit breaker,Special Insructions/ Power Failure To Normal Heating DemandFuel TroubleshootingHelpful Hints Electrical VAC 60 Hz SpecificationsBTU Input Range= 0, and 9350 to 60,000 PIN DiagramPlug Warranty ECO-CHOICE Limited WarrantyTesting Label EFEBh105 Bh60 Stocked #11 Feeder Assembly Page Quick Reference Auto-Light Signature of Boxer

BH60 specifications

The Heatiator BH60 is an innovative heating solution designed to enhance indoor comfort while maximizing energy efficiency. This state-of-the-art heater combines advanced technology with user-friendly features, making it an ideal choice for both residential and commercial applications.

One of the standout features of the Heatiator BH60 is its powerful heating capability. The unit can produce an impressive amount of heat, making it suitable for larger spaces. With an adjustable thermostat, users can easily set their desired temperature, ensuring a cozy environment regardless of the season. Additionally, the unit employs a rapid heating technology that allows it to warm up spaces quickly, reducing the wait time for comfort.

The Heatiator BH60 is equipped with energy-saving technologies to minimize power consumption while maximizing output. The unit utilizes a smart energy management system that monitors usage patterns and adjusts heating levels accordingly. This not only helps in reducing energy bills but also contributes to a more sustainable environment. The heater is also designed to operate quietly, making it perfect for use in bedrooms, living rooms, and offices without disturbing daily activities.

Another significant characteristic of the Heatiator BH60 is its safety features. The heater is built with overheat protection, which automatically shuts off the unit if it reaches unsafe temperature levels. Additionally, the unit is constructed with flame-resistant materials, adding an extra layer of safety. It also comes with a tip-over switch that automatically turns off the heater if it is knocked over, making it a safe option for households with pets and children.

The design of the Heatiator BH60 is both sleek and modern, allowing it to blend seamlessly into various interior styles. Its compact size ensures it does not take up much space, making it easy to place it in different locations according to needs. Users appreciate the straightforward controls, which provide a hassle-free experience when adjusting settings.

In conclusion, the Heatiator BH60 stands out as an effective and efficient heating solution. With its robust heating capabilities, energy-efficient technologies, and a focus on safety, it is an excellent choice for anyone looking to improve their indoor climate. Whether in a home or office, the Heatiator BH60 promises to deliver comfort and warmth in a reliable manner.