Ariston
47-116-15
installation instructions
Servicing Instructions Type C Boilers
Install
Electrical Diagram
Fault Finding
Dimension
Maintenance
GAS Adjustments
Setting the gas pressures
Safety
Page 25
Servicing
Instructions
Type C Boilers
G.C.N:
47-116-14
47-116-15
LEAVE THESE INSTRUCTIONS WITH THE
END-USER
Country of destination: GB
Page 24
Page 26
Image 25
Page 24
Page 26
Contents
Installation Instructions Type C Boilers
Table of Contents
General Information
Overall View
Installation
Overall Dimensions
Supply must be fused at 3 a
Domestic Water
Tonbridge
Morley Road
Kent TN9 1RA
80 mm
Systems
Restrictor Extension Piping not insulated Piping insulated
Restrictor No Restrictor
Extension Piping not insulated Piping insulated
Calculating the lengths of the pipes,
Electrical Diagram
Central Heating Return
Commissioning
Control Panel
Initial START-UP Operational Adjustments
Status
ANTI-FROST Device
Methane Liquid Gas Butane
GAS Adjustments
G20 Gas G30
16.0
Maintenance
Boiler
Miscellaneous
Programmer
Technical Information
Technical Service Hot Line 01494
Manufacturer Merloni TermoSanitari SpA Italy
Servicing Instructions Type C Boilers
Fault Finding
Removing the front panel
Servicing Instructions
Removing the side panels
Removing the sealed chamber frontal cover
Removing the burner and jets
Removing the combustion cover
Removing the electrodes
Removing the main heat exchanger
Removing the fan
Removing the air pressure switch
Setting the minimum and the maximum power of the boiler
Setting the gas pressures
Setting the maximum heating circuit power
Setting pressure for soft ignition
Regulating the heating power for Butane gas G30
Regulating the heating power for Natural gas G20
Regulating the heating power for Propane gas G31
Removing the spark generator
Removing the D.H.W. secondary exchanger
Removing the gas valve
Removing the main circuit flow switch
Removing the safety valve
Removing the automatic air vent
Removing the pump
Removing the expansion vessel
Removing the pressure gauge
Removing the heating temperature sensor N.T.C
Removing the D.H.W. temperature sensor N.T.C
Removing the D.H.W. flow switch
Removing the overheat thermostat
Removing the time clock
Checking the fuses
Removing the P.C.B
Finding diagrams described in this chapter
Fault Finding
YES
YES
∆ P 1.2 mbar
YES
Electrical Diagrams
MicroGENUS 23/27 Mffi
MicroGENUS 23/27 Mffi
Ariston
Page
Manufacturer Merloni TermoSanitari SpA Italy
Microgenus 27 Mffi
Cod
Part Code Description
998924 Panel combustion chamber front
571770 Main flow switch top cap
Related pages
Troubleshooting for Sterling SCD 10
Specification of Housing for Swann 1060
Fault code Å 30 is dis for AEG 40860
System Block Diagram for Spirit UltraMic Plus
Golden rules when pressure cooking for UK Consumers for Tefal P2504042
User Installation Guide for Samsung 460MX-3
Replacement Parts Illustrations and Parts Lists for 3M 39600
Free Mower Safety Video for Woods Equipment BB72X
General tips for troubleshooting Samsung washing machines.
Troubleshooting
Top
Page
Image
Contents