Ariston 47-116-15 Removing the overheat thermostat, Removing the D.H.W. temperature sensor N.T.C

Page 39

Removing the overheat thermostat

1.Disconnect the overheat thermostat electrical connections “N1” (FIG. 1.54);

2.Then remove the thermostat from its mounting by releasing the securing clip (FIG. 1.55).

N1

80.eps

FIG. 1.54

 

 

83.eps

FIG. 1.55

Removing the D.H.W. temperature sensor (N.T.C.)

1.Pull off the electrical connector “Q1” and unscrew the sensor probe using a suitable spanner (FIG. 1.57).

 

Q1

60.eps

FIG. 1.57

Removing the divertor valve actuator

1.Unplug the electrical connector “R1” (FIG. 1.58);

2.Release the retaining clip “S1” and remove the divertor valve actuator.

R1

S1

74.eps

FIG. 1.58

Removing the heating temperature sensor (N.T.C.)

1.Pull off the electrical connector “P1” and unscrew the sensor probe using a suitable spanner (FIG. 1.56).

 

 

 

 

 

 

P1

 

 

 

 

 

 

FIG. 1.56

87.eps

 

 

 

 

 

Removing the D.H.W. flow switch

1.Unplug the electrical connector “T1” (FIG. 1.59);

2.Release the retaining clip “V1” and remove the D.H.W. flow switch.

V1

30.eps

T1

FIG. 1.59

B063

15

Image 39
Contents Installation Instructions Type C Boilers Table of Contents General Information Overall View Installation Overall Dimensions Supply must be fused at 3 a Domestic Water Morley Road TonbridgeKent TN9 1RA 80 mm Extension Piping not insulated Piping insulated Restrictor Extension Piping not insulated Piping insulatedSystems Restrictor No RestrictorCalculating the lengths of the pipes, Electrical Diagram Central Heating Return Commissioning Control Panel Initial START-UP Operational Adjustments Status ANTI-FROST Device 16.0 GAS AdjustmentsMethane Liquid Gas Butane G20 Gas G30Maintenance Boiler MiscellaneousProgrammer Technical Service Hot Line 01494 Technical InformationManufacturer Merloni TermoSanitari SpA Italy Servicing Instructions Type C Boilers Fault Finding Removing the front panel Servicing InstructionsRemoving the side panels Removing the sealed chamber frontal coverRemoving the combustion cover Removing the burner and jetsRemoving the electrodes Removing the main heat exchanger Removing the fan Removing the air pressure switchSetting pressure for soft ignition Setting the gas pressuresSetting the minimum and the maximum power of the boiler Setting the maximum heating circuit powerRegulating the heating power for Natural gas G20 Regulating the heating power for Butane gas G30Regulating the heating power for Propane gas G31 Removing the spark generator Removing the D.H.W. secondary exchanger Removing the gas valveRemoving the safety valve Removing the main circuit flow switchRemoving the automatic air vent Removing the pump Removing the expansion vessel Removing the pressure gaugeRemoving the overheat thermostat Removing the D.H.W. temperature sensor N.T.CRemoving the heating temperature sensor N.T.C Removing the D.H.W. flow switchRemoving the time clock Checking the fusesRemoving the P.C.B Finding diagrams described in this chapter Fault FindingYES YES ∆ P 1.2 mbar YES Electrical Diagrams MicroGENUS 23/27 Mffi MicroGENUS 23/27 Mffi Ariston Page Manufacturer Merloni TermoSanitari SpA Italy Microgenus 27 Mffi Cod Part Code Description 998924 Panel combustion chamber front 571770 Main flow switch top cap