Ariston 47-116-15 installation instructions Part Code Description

Page 55

PART

CODE

DESCRIPTION

REF.

NOTE

1

------

Frame

 

11

2

998616

Expansion vessel

 

 

3

998776

Bush

 

 

4

998581

3/8" lock nut

 

 

5

573521

Gasket 3/8"

 

 

6

999102

Pipe (expansion vessel)

 

 

7

998580

Cable holder

 

 

8

------

Hydraulic group support

 

11

9

570717

Spring (fastening)

 

 

10

998569

Pivot

 

 

11

998589

By-pass pipe

 

 

12

998077

O-ring gasket

 

 

13

998064

Spring (by-pass pipe)

 

 

14

573520

Gasket 3/4"

 

 

15

999103

Pipe (flow)

 

 

16

997147

Motor (3-Way valve)

 

 

17

997077

Fixing clip (motor)

 

 

18

569236

Temperature probe (C.H.W.)

 

 

19

998613

Flow group

 

 

20

571547

Diaphragm (main flow switch)

 

 

21

998099

Main circuit flow switch

 

 

22

998632

Cable (temperature probes)

 

 

23

999075

D.H.W. flow switch

 

 

24

998940

Return group

 

 

25

998424

O-ring

 

 

26

574279

Gasket

 

 

27

998645

Spark generator

 

 

28

997089

Gas valve (SIT 845 SIGMA)

 

 

29

998606

Pump bracket

 

 

30

998568

Pump plug

 

 

31

997182

Gasket

 

 

32

999100

Lock washer

 

 

33

999091

Pump

 

 

34

998570

L.E.D.

 

 

35

998575

Spindle (temperature knob)

 

 

36

998603

Control knob

 

 

37

998572

Spindle (on/off knob)

 

 

38

997207

Time clock

 

 

39

999059

Front cover

 

 

40

998824

Control panel

 

 

41

998947

Printed circuit board (CMP1-FFI)

 

 

42

569711

Nylon bush (10mm)

 

 

43

998625

Pressure gauge

 

 

44

998952

Control panel

 

 

45

998953

Cable holder cover

 

 

46

571548

Clip(Main Flow Switch)

 

 

47

998861

Cable (power supply)

 

 

48

999153

High voltage wiring

 

 

49

998863

Low voltage wiring

 

 

50

573327

Y piece (air pressure)

 

 

51

571651

Air pressure switch

 

 

52

997203

Support plate (Air pressure switch)

 

 

53

573329

Pressure intake cover

 

 

54

571575

Silicone pipe (positive signal)

 

 

55

998516

Gasket (adhesive 10x6)

 

 

56

------

Sealed chamber

 

11

57

998565

Cover (flue test point)

 

 

58

998636

Gasket (flue test point)

 

 

59

998602

Flue (exhaust manifold/header)

 

 

60

998637

Flange gasket

 

 

61

998595

Plug (air intake)

 

 

62

998648

Wiring loom (fan/air pressure switch)

 

 

63

998566

Fixing clamp (fan)

 

 

64

573446

Fan seal (silicone)

 

 

65

998943

O-ring (2.65 x 101.27)

 

 

Image 55
Contents Installation Instructions Type C Boilers Table of Contents General Information Overall View Installation Overall Dimensions Supply must be fused at 3 a Domestic Water Tonbridge Morley RoadKent TN9 1RA 80 mm Extension Piping not insulated Piping insulated Restrictor Extension Piping not insulated Piping insulatedSystems Restrictor No RestrictorCalculating the lengths of the pipes, Electrical Diagram Central Heating Return Commissioning Control Panel Initial START-UP Operational Adjustments Status ANTI-FROST Device 16.0 GAS AdjustmentsMethane Liquid Gas Butane G20 Gas G30Maintenance Boiler MiscellaneousProgrammer Technical Information Technical Service Hot Line 01494Manufacturer Merloni TermoSanitari SpA Italy Servicing Instructions Type C Boilers Fault Finding Removing the front panel Servicing InstructionsRemoving the side panels Removing the sealed chamber frontal coverRemoving the burner and jets Removing the combustion coverRemoving the electrodes Removing the main heat exchanger Removing the fan Removing the air pressure switchSetting pressure for soft ignition Setting the gas pressuresSetting the minimum and the maximum power of the boiler Setting the maximum heating circuit powerRegulating the heating power for Butane gas G30 Regulating the heating power for Natural gas G20Regulating the heating power for Propane gas G31 Removing the spark generator Removing the D.H.W. secondary exchanger Removing the gas valveRemoving the main circuit flow switch Removing the safety valveRemoving the automatic air vent Removing the pump Removing the expansion vessel Removing the pressure gaugeRemoving the overheat thermostat Removing the D.H.W. temperature sensor N.T.CRemoving the heating temperature sensor N.T.C Removing the D.H.W. flow switchRemoving the time clock Checking the fusesRemoving the P.C.B Finding diagrams described in this chapter Fault FindingYES YES ∆ P 1.2 mbar YES Electrical Diagrams MicroGENUS 23/27 Mffi MicroGENUS 23/27 Mffi Ariston Page Manufacturer Merloni TermoSanitari SpA Italy Microgenus 27 Mffi Cod Part Code Description 998924 Panel combustion chamber front 571770 Main flow switch top cap