Desa LCR26PT Mounting heater to floor With optional floor kit, Attaching To Wall Anchor Method

Page 10

Installation

Continued

Attaching To Wall Anchor Method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" (2.5 cm) deep.

2.Fold wall anchor as shown in Figure 9.

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls [1/2" (1.3 cm) or less], insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls [over 1/2" (1.3 cm) thick] or solid walls, do not pop open wings.

5.Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Figure 9 - Folding

Figure 10 - Popping

Anchor

Open Anchor Wings

 

For Thin Walls

Placing Heater On Mounting Bracket

1.Locate two horizontal slots on back panel of heater.

2.Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Horizontal Slots

2.Mark screw locations on wall.

3.Remove heater from mounting bracket.

4.If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method.

If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64" drill bit.

5.Replace heater onto mounting bracket.

6.Place spacers between bottom mounting holes and wall anchor or drilled hole.

7.Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.

8.Tighten both screws until heater is firmly secured to wall. Do not over tighten.

Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see page 11).

Front View

Wall

Heater

Spacer

Side View

Figure 12 - Installing Bottom Mounting

Screws

Stand-Out Tab

Mounting Bracket (attached to wall)

Mounting heater to floor With optional floor kit

Mounting Base Feet to Heater

Note: A 90° elbow is required for mounting this unit and must be installed BEFORE base feet to provide proper clearance (see Figure 15, page 12).

Figure 11 - Mounting Heater Onto

Mounting Bracket

Installing Bottom Mounting Screws

1.Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 12).

1.Lay heater cabinet on its back on a table with the heater bottom overhanging table edge.

2.Apply pipe joint sealant lightly to male NPT threads of elbow. Hold pressure regulator with a wrench when connecting elbow. Do not overtighten elbow to regulator. Regulator body could be damaged.

10

www.desatech.com

121255-01A

Image 10
Contents What to do if YOU Smell GAS ModelsTable of Contents SafetySafety Local Codes SafetyProduct Features UnpackingUnusually Tight Construction Air For Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceVentilation AIR AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined Space Check GAS Type Installation Installation Items Ventilation Air From OutdoorsLocating Heater Thermostat Sensing BulbInstalling Heater to Wall Attaching To Wall Anchor Method Installing Bottom Mounting ScrewsMounting heater to floor With optional floor kit Placing Heater On Mounting BracketMounting Base Feet to Floor Connecting to GAS SupplyTypical Inlet Pipe Diameters Checking GAS Connections Operation For Your Safety Read Before LightingPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaDo not try to light any appliance Lighting InstructionsThermocouple Ignitor Electrode Pilot Burner To Turn OFF GAS To Appliance Manual Lighting ProcedureTo Select Heating Level Thermostat ControlPilot Flame Pattern CleaningInspecting Heater Burner Flame PatternODS/PILOT and Burner Service HintsTechnical Service Burner Pilot Air InletTroubleshooting Observed Problem Possible Cause RemedyHeaters. If noise is exces TroubleshootingReplace burner orifices Is lit or shut off CoolingNot enough fresh air is Gas odor even when controlIng furniture polish, wax LP gas onlySpecifications AccessoriesParts Cabinet body ModelsKEY Parts Burner Assembly Models120630-03 099387-11 104818-04 099218-09 099056-25 099056-02 Parts Under Warranty Replacement PartsService Publications Parts Central Parts Not Under WarrantyKeep this Warranty WarrantyModel Serial No Date of Purchase QUÉ Hacer SI Percibe Olor a GAS ModelosTabla de contenido Seguridad Intoxicación con monóxido de carbonoIdentificación del Producto Códigos localesDesempaque Saque el calentador de la cajaAire para combustión Ventilación Características del ProductoCómo Procurar LA Ventilación Adecuada Aire Para Combustión Ventilación Espacio confinado y no confinadoAire Para Ventilación Aire del interior de la construcción para ventilaciónArtículos DE Instalación InstalaciónVerifique EL Tipo DE GAS Ubicación DEL CalentadorInstalación DEL Calentador EN LA Pared Bulbo Sensor DE TermostatoSoporte de montaje Cómo marcar las ubicaciones de los tornillos Desmontaje del panel anterior del calentadorMétodos para fijar el soporte de montaje a la pared Calentador con 3 placasColocación del calentador en el soporte de montaje Método de fijación a viga de paredInstalación de los tornillos de montaje inferiores Montaje de las patas de la base en el calentador Conexión AL Suministro DE GASMontaje de las patas de la base en el piso Unión T Sin rosca Válvula de Buje Reductor Cierre del Regulador Niple para De presión Tubería de Soporte del TipoGabinete del Unión Calentador Pulimentada EquipoRevisión DE LAS Conexiones DE GAS Repare todas las fugas inmediatamenteCierre del Equipo Cerrada Repare todas las fugas inmediatamente Válvula deSuministro De propano Gas LP Válvula de cierre del equipo POR SU SEGURIDAD, LEA Esto Antes DE Encender EL Calentador FuncionamientoInstrucciones DE Encendido Termopar Electrodo del encendedor Quemador Del piloto Para Seleccionar EL Nivel DE CalefacciónPerilla de control Botón del encendedor Perilla de control QuemadoresTermostato Funcionamiento Cómo Cerrar EL Suministro DE GAS AL AparatoControl CON Procedimiento Para Encendido ManualPatrón DE LA Llama DEL Calentador Inspección del CalentadorPatrón DE LA Llama DEL Piloto Termopar Del pilotoEntrada de aire al piloto del quemador LimpiezaPiloto CON ODS Y Quemador GabineteSolución de problemas Problema Observado Causa Posible RemedioSolución DE Problemas Continuación Causa Posible RemedioSolución DE Problemas Anotación de advertencia Consejos para servicio EspecificacionesAccesorios Servicio técnicoPiezas Modelos con gabineteConjunto de herrajes Abrazadera de cablePiezas Modelos con conjunto de quemadorPiezas con garantía Piezas de repuestoPublicaciones de Servicio Piezas sin garantíaModelo De serie Fecha de compra GarantíaGuarde Esta Garantía 121255-01 Rev. a 03/07