12.Operating heater above elevations of 4,500 feet (1,371 m) could cause pilot outage.

13.To prevent performance problems, do not usepropane/LPfueltankoflessthan100lbs. (45 kg) capacity.

14.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

15.Provide adequate clearances around air openings.

Local Codes

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas- sachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

Unpacking

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly return to where you bought heater.

Product

Identification

Control Knob

Ignitor Button

Grill

Guard

Plaque

Front Panel

Heater Cabinet

Figure 1 - Vent-Free Gas Heater

Product Features

Safety Device

This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Piezo Ignition System

This heater has a piezo ignitor. This system re- quires no matches, batteries or other sources to light heater.

Thermostatic Heat Control

Thermostat models have a thermostat sens- ing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.

www.desatech.com121255-01A

Image 4
Contents What to do if YOU Smell GAS ModelsTable of Contents SafetySafety Safety Product FeaturesLocal Codes UnpackingAir For Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceInstallation Installation ItemsCheck GAS Type Ventilation Air From OutdoorsLocating Heater Thermostat Sensing BulbInstalling Heater to Wall Installing Bottom Mounting Screws Mounting heater to floor With optional floor kitAttaching To Wall Anchor Method Placing Heater On Mounting BracketMounting Base Feet to Floor Connecting to GAS SupplyTypical Inlet Pipe Diameters Checking GAS Connections For Your Safety Read Before Lighting Pressure Testing Heater Gas ConnectionsOperation Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaDo not try to light any appliance Lighting InstructionsThermocouple Ignitor Electrode Pilot Burner Manual Lighting Procedure To Select Heating LevelTo Turn OFF GAS To Appliance Thermostat ControlCleaning Inspecting HeaterPilot Flame Pattern Burner Flame PatternService Hints Technical ServiceODS/PILOT and Burner Burner Pilot Air InletTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Replace burner orificesHeaters. If noise is exces Is lit or shut off CoolingGas odor even when control Ing furniture polish, waxNot enough fresh air is LP gas onlySpecifications AccessoriesParts Cabinet body ModelsKEY Parts Burner Assembly Models120630-03 099387-11 104818-04 099218-09 099056-25 099056-02 Replacement Parts Service Publications Parts CentralParts Under Warranty Parts Not Under WarrantyKeep this Warranty WarrantyModel Serial No Date of Purchase QUÉ Hacer SI Percibe Olor a GAS ModelosTabla de contenido Seguridad Intoxicación con monóxido de carbonoCódigos locales DesempaqueIdentificación del Producto Saque el calentador de la cajaAire para combustión Ventilación Características del ProductoCómo Procurar LA Ventilación Adecuada Aire Para Combustión Ventilación Espacio confinado y no confinadoAire Para Ventilación Aire del interior de la construcción para ventilaciónInstalación Verifique EL Tipo DE GASArtículos DE Instalación Ubicación DEL CalentadorInstalación DEL Calentador EN LA Pared Bulbo Sensor DE TermostatoSoporte de montaje Desmontaje del panel anterior del calentador Métodos para fijar el soporte de montaje a la paredCómo marcar las ubicaciones de los tornillos Calentador con 3 placasColocación del calentador en el soporte de montaje Método de fijación a viga de paredInstalación de los tornillos de montaje inferiores Montaje de las patas de la base en el calentador Conexión AL Suministro DE GASMontaje de las patas de la base en el piso Regulador Niple para De presión Tubería de Soporte del Tipo Gabinete del Unión Calentador PulimentadaUnión T Sin rosca Válvula de Buje Reductor Cierre del EquipoRevisión DE LAS Conexiones DE GAS Repare todas las fugas inmediatamenteCierre del Equipo Cerrada Repare todas las fugas inmediatamente Válvula deSuministro De propano Gas LP Válvula de cierre del equipo POR SU SEGURIDAD, LEA Esto Antes DE Encender EL Calentador FuncionamientoInstrucciones DE Encendido Para Seleccionar EL Nivel DE Calefacción Perilla de control Botón del encendedorTermopar Electrodo del encendedor Quemador Del piloto Perilla de control QuemadoresCómo Cerrar EL Suministro DE GAS AL Aparato Control CONTermostato Funcionamiento Procedimiento Para Encendido ManualInspección del Calentador Patrón DE LA Llama DEL PilotoPatrón DE LA Llama DEL Calentador Termopar Del pilotoLimpieza Piloto CON ODS Y QuemadorEntrada de aire al piloto del quemador GabineteSolución de problemas Problema Observado Causa Posible RemedioSolución DE Problemas Continuación Causa Posible RemedioSolución DE Problemas Anotación de advertencia Especificaciones AccesoriosConsejos para servicio Servicio técnicoPiezas Modelos con gabineteConjunto de herrajes Abrazadera de cablePiezas Modelos con conjunto de quemadorPiezas de repuesto Publicaciones de ServicioPiezas con garantía Piezas sin garantíaGarantía Guarde Esta GarantíaModelo De serie Fecha de compra 121255-01 Rev. a 03/07