Specifications

LCR18NT, HDR18NT

Natural Gas

18,000 Btu/hr

Piezo Ignition

Pressure Regulator Setting: 6" W.C.

Inlet Gas Pressure* (in. of water): Maximum - 10.5" W.C., Minimum - 7" W.C.

Average Heater Weight: 22 lb (10 kg)

Average Shipping Weight: 25.5 lb (11.6 kg)

LCR16PT, HDR16PT

Propane/LP Gas

16,000 Btu/hr

Piezo Ignition

Pressure Regulator Setting: 8" W.C.

Inlet Gas Pressure* (in. of water): Maximum - 14" W.C., Minimum - 11" W.C.

Average Heater Weight: 22 lb (10 kg)

Average Shipping Weight: 25.5 lb (11.6 kg)

LCR30NT, HDR30NT

Natural Gas

30,000 Btu/hr

Piezo Ignition

Pressure Regulator Setting: 6" W.C.

Inlet Gas Pressure* (in. of water): Maximum - 10.5" W.C., Minimum - 7" W.C.

Average Heater Weight; 29 lb (13.2 kg)

Average Shipping Weight: 33 lb (15 kg)

LCR26PT, HDR26PT

Propane/LP Gas

26,000 Btu/hr

Piezo Ignition

Pressure Regulator Setting: 8" W.C.

Inlet Gas Pressure* (in. of water): Maximum - 14" W.C., Minimum - 11" W.C.

Average Heater Weight: 29 lb (13.2 kg)

Average Shipping Weight: 33 lb (15 kg)

Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).

* For purposes of input adjustment.

Accessories

Purchase these heater accessories from your local dealer. If they can not supply these ac- cessories, either contact your nearest Parts Central (see page 25) or call DESA Heating Products at 1-866-672-6040 for referral in- formation. You can also write to the address listed on the back page of this manual.

Electronic ignitor Kit - GA435 Not Shown

For all piezo ignitor models. Provides easier

lighting of the pilot.

equipment SHUTOFF VALVE GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap.

121255-01A

www.desatech.com

21

Image 21
Contents Models What to do if YOU Smell GASSafety Table of ContentsSafety Product Features SafetyLocal Codes UnpackingProviding Adequate Ventilation Air For Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationVentilation AIR Determining if You Have a Confined or Unconfined SpaceInstallation Items InstallationCheck GAS Type Ventilation Air From OutdoorsThermostat Sensing Bulb Locating HeaterInstalling Heater to Wall Mounting heater to floor With optional floor kit Installing Bottom Mounting ScrewsAttaching To Wall Anchor Method Placing Heater On Mounting BracketConnecting to GAS Supply Mounting Base Feet to FloorTypical Inlet Pipe Diameters Checking GAS Connections Pressure Testing Heater Gas Connections For Your Safety Read Before LightingOperation Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaLighting Instructions Do not try to light any applianceThermocouple Ignitor Electrode Pilot Burner To Select Heating Level Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat ControlInspecting Heater CleaningPilot Flame Pattern Burner Flame PatternTechnical Service Service HintsODS/PILOT and Burner Burner Pilot Air InletObserved Problem Possible Cause Remedy TroubleshootingReplace burner orifices TroubleshootingHeaters. If noise is exces Is lit or shut off CoolingIng furniture polish, wax Gas odor even when controlNot enough fresh air is LP gas onlyAccessories SpecificationsCabinet body Models PartsKEY Burner Assembly Models Parts120630-03 099387-11 104818-04 099218-09 099056-25 099056-02 Service Publications Parts Central Replacement PartsParts Under Warranty Parts Not Under WarrantyWarranty Keep this WarrantyModel Serial No Date of Purchase Modelos QUÉ Hacer SI Percibe Olor a GASTabla de contenido Intoxicación con monóxido de carbono SeguridadDesempaque Códigos localesIdentificación del Producto Saque el calentador de la cajaCaracterísticas del Producto Aire para combustión VentilaciónCómo Procurar LA Ventilación Adecuada Espacio confinado y no confinado Aire Para Combustión VentilaciónAire del interior de la construcción para ventilación Aire Para VentilaciónVerifique EL Tipo DE GAS InstalaciónArtículos DE Instalación Ubicación DEL CalentadorBulbo Sensor DE Termostato Instalación DEL Calentador EN LA ParedSoporte de montaje Métodos para fijar el soporte de montaje a la pared Desmontaje del panel anterior del calentadorCómo marcar las ubicaciones de los tornillos Calentador con 3 placasMétodo de fijación a viga de pared Colocación del calentador en el soporte de montajeInstalación de los tornillos de montaje inferiores Conexión AL Suministro DE GAS Montaje de las patas de la base en el calentadorMontaje de las patas de la base en el piso Gabinete del Unión Calentador Pulimentada Regulador Niple para De presión Tubería de Soporte del TipoUnión T Sin rosca Válvula de Buje Reductor Cierre del EquipoRepare todas las fugas inmediatamente Revisión DE LAS Conexiones DE GASRepare todas las fugas inmediatamente Válvula de Cierre del Equipo CerradaSuministro De propano Gas LP Válvula de cierre del equipo Funcionamiento POR SU SEGURIDAD, LEA Esto Antes DE Encender EL CalentadorInstrucciones DE Encendido Perilla de control Botón del encendedor Para Seleccionar EL Nivel DE CalefacciónTermopar Electrodo del encendedor Quemador Del piloto Perilla de control QuemadoresControl CON Cómo Cerrar EL Suministro DE GAS AL AparatoTermostato Funcionamiento Procedimiento Para Encendido ManualPatrón DE LA Llama DEL Piloto Inspección del CalentadorPatrón DE LA Llama DEL Calentador Termopar Del pilotoPiloto CON ODS Y Quemador LimpiezaEntrada de aire al piloto del quemador GabineteProblema Observado Causa Posible Remedio Solución de problemasCausa Posible Remedio Solución DE Problemas ContinuaciónSolución DE Problemas Anotación de advertencia Accesorios EspecificacionesConsejos para servicio Servicio técnicoModelos con gabinete PiezasAbrazadera de cable Conjunto de herrajesModelos con conjunto de quemador PiezasPublicaciones de Servicio Piezas de repuestoPiezas con garantía Piezas sin garantíaGuarde Esta Garantía GarantíaModelo De serie Fecha de compra 121255-01 Rev. a 03/07