Troubleshooting
WARNING:Turnoffandunplugheaterandletcoolbeforeservicing. Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
|
|
|
| |
When ignitor button is | 1. Ignitor electrode positioned | 1. | Replace pilot assembly | |
pressed in, there is no spark |
| wrong |
|
|
at ODS/pilot | 2. Ignitor electrode broken | 2. | Replace pilot assembly | |
| 3. | Ignitor electrode not con- | 3. | Reconnect ignitor cable |
|
| nected to ignitor cable |
|
|
| 4. | Ignitor cable pinched or | 4. | Free ignitor cable if pinched |
|
| wet |
| by any metal or tubing. |
|
|
|
| Keep ignitor cable dry |
| 5. | Broken ignitor cable | 5. | Replace ignitor cable |
| 6. | Bad ignitor | 6. | Replace ignitor |
| 7. | Piezo ignitor nut is loose | 7. | Tighten nut holding piezo |
|
|
|
| ignitor. Nut is located inside |
|
|
|
| heater cabinet at top |
|
|
|
| |
When ignitor button is | 1. Gas supply turned off or equip- | 1. | Turn on gas supply or open | |
pressed in, there is a spark |
| ment shutoff valve closed |
| equipment shutoff valve |
at ODS/Pilot but no ignition | 2. Control knob is not in pilot | 2. | Turn control knob to pilot | |
|
| position |
| position |
| 3. | Control knob not fully | 3. | Turn to PILOT/IGN position. |
|
| pressed in while pressing |
| Fully press in control knob |
|
| ignitor button |
| while pressing ignitor button |
| 4. | Air in gas lines when in- | 4. | Continue holding down |
|
| stalled |
| control knob. Repeat ignit- |
|
|
|
| ing operation until air is |
|
|
|
| removed |
| 5. | Depleted gas supply (pro- | 5. | Contact local propane/LP |
|
| pane/LP gas) |
| gas company |
| 6. | ODS/pilot is clogged | 6. | Clean ODS/pilot (see |
|
|
|
| Cleaning, page 16) or re- |
|
|
|
| place ODS/pilot assembly |
| 7. | Gas regulator setting is not | 7. | Replace gas regulator |
|
| correct |
|
|
|
|
|
| |
Moisture/condensation no- | 1. Not enough combustion/ | 1. | Refer to Air for Combustion | |
ticed on windows |
| ventilation air |
| and Ventilation require- |
|
|
|
| ments (page 5) |
18 | www.desatech.com |