J. Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.
•DO NOT strike, slam or scratch glass.
•DO NOT operate fireplace with glass removed, cracked, broken or scratched.
•Replace as a complete assembly.
Removing Fixed Glass Assembly
•Lift and pull upper grille towards you to expose two (36 in. model) or three (42 in. model) Quick Access Latches.
•Open the control access panel to expose two (36 in. model) or three (42 in. model) Quick Access Latches.
•Rotate bottom of screen assembly away from appliance and lower out of top retainers.
•Release top and bottom access latches and rotate top of the glass assembly away from top of appliance.
•Place the glass assembly on a surface that will not scratch the surface of glass assembly.
Replacing Fixed Glass Assembly
•Replace the glass assembly on lower access latches and rotate upper portion of glass assembly into place.
•Engage top access latches.
•Engage lower access latches.
•Reinstall top corners of screen assembly in their retainer clips and rotate screen assembly to rest on lower latches.
•Close access panel and reinstall upper grille.
Latches
(both bottom
and top)
Glass
Assembly
Figure 14.3 Fixed Glass Assembly
K. Install Trim and/or Surround
•Install optional trim kits and/or surrounds using the instructions included with the accessory.
•Use
•Do not obstruct or modify the air inlet/outlet louvers.
•Allow space to lower and remove bottom louver/access panel.
L. Install Hood
•Align back edge of hood with attachment clips and press firmly into place.
M. Air Shutter Setting
Air shutter settings should be adjusted by a qualified installer at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shut- ter for longer vertical runs. See Figure 14.4.
•16 full turns of the shutter adjustment handle are required to move air shutter from fully open to fully closed.
•When the shutter adjustment handle is all the way down, the air shutter is in the closed position.
NOTICE: If sooting occurs, provide more air by opening the air shutter.
Closed
Figure 14.4 Air Shutter
56 | Heatilator • Caliber CD Series • |