Burnham MMII manual Dimensional Drawing

Page 3

 

HOUSE HEATING

DOMESTIC WATER

 

 

 

 

 

 

 

 

PIPING

 

COMBUSTION

 

 

 

 

 

 

COIL CONNECTION

GAS SUPPLY

FLUE VENT

WATER CAPACITY

 

APPROX.

 

CONNECTION

 

 

(INCHES)

AIR INTAKE

 

 

'A'

 

(INCHES)

CONNECTION

CONNECTION

 

 

SHIPPING

 

 

 

CONNECTION

 

 

 

 

 

 

 

(INCHES)

(DIA. - INCHES)

 

 

 

WEIGHT

BOILER

SUPPLY

RETURN

WATER

WATER

(DIA. - INCHES)

BOILER

TANK

 

 

 

 

 

 

MODEL

(NPT)

(NPT)

IN (NPT)

OUT (NPT)

 

 

 

(GALLONS)

(GALLONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MMII4-70

 

 

 

 

 

 

 

2-1/2

 

5-7/8

307 LB.

 

 

 

 

 

 

 

 

 

MMII4-105

1-1/4

1-1/4

1/2

1/2

1/2

4

3

17.6

 

 

 

 

 

 

 

MMII5-105

3

5-1/8

345 LB.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MMII5-140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1: Dimensional Drawing

3

Image 3
Contents 81404025R13-1/07 Price $3.00 MinutemanTable of Contents Dimensional Drawing Minimum Clearances to Combustible Surfaces Pre-InstallationII. Unpack Boiler III. Water Piping and TrimDo not drop boiler. Do not bump boiler jacket against floor Page Internal Water Piping System Diagram Domestic Hot Water Ratings IV. Domestic Hot Water Performance and PipingRated Input Gas PipingSpecific Gravity Correction Factors Fitting Equivalent LengthsVent/Air Intake Length VI. Venting / Air Intake PipingComponent General GuidelinesBurnham Vent System Components Install Vent ConnectorInstall Vent Pipe, General Install Vent Pipe, Burnham Gasket-Less Vent SystemInstall Vent Pipe, Burnham Gasketed Vent System Burnham Gasketed Vent Joint Detail Horizontal Through Wall Vent InstallationRecommended Horizontal Vent Installation Horizontal Vent Pipe Wall Penetration Vertical Through Roof Vent InstallationInstall Air Intake Pipe Vertical Vent InstallationVII. Electrical Wiring DiagramDo not install an automatic fill valve with this boiler VIII. System Start-upPrepare to check operation Operating Instructions Check Boiler High Limit Adjust gas input rate to boilerGas Flow Rate in Cubic Feet per Hour IX. Service Lubrication Main Burners and Combustion ChamberBurner and Flueway Cleaning Pilot Burner Location Differential Pressure Switch SettingsAvoid Breathing Fiber Particulates and Dust Page Page Cerafelt Gasketing not depicted Repair PartsHeat Exchanger Assembly Canopy/Blower AssemblyPage Page Base Assembly Page Page Jacket Assembly Domestic Water Tank Assembly Miscellaneous Trim and Controls Air Intake Terminal Vent Accessory CartonLimited Warranty