Burnham MMII manual Fitting Equivalent Lengths, Specific Gravity Correction Factors

Page 10

NOTICE

USA boilers built for installation at altitudes greater than 2,000 feet above sea level have been specially orificed to reduce gas input rate 4 percent per 1,000 feet above sea level per the National Fuel Gas Code, ANSI Z223.1, Section 8.1.2 and Appendix F. Canadian boilers' orifice siz ing is indicated on the rating label. High altitude boiler models are identifiable by the model number suffix "H" on the rating label.

Table 4: Fitting Equivalent Lengths

Fitting

 

Nominal Pipe Size

 

 

 

 

 

 

 

½

 

¾

1

 

 

 

 

 

 

 

 

 

 

 

45° Ell

0.7

 

1

1.2

 

1.6

 

 

 

 

 

 

 

90° Ell

1.6

 

2.1

2.6

 

3.5

 

 

 

 

 

 

 

Tee (As Elbow)

3.1

 

4.1

5.2

 

6.9

 

 

 

 

 

 

 

C.Pressure test. The boiler and its gas connection must be leak tested before placing boiler in operation.

1. Protect boiler gas control valve. For all testing over ½ psig, boiler and its individual shutoff valve must be disconnected from gas supply piping. For testing at ½ psig or less, isolate boiler from gas supply piping by closing boiler's individual manual shutoff valve.

Table 5: Specific Gravity Correction Factors

Specific

Correction

Specific

Correction

Gravity

Factor

Gravity

Factor

 

 

 

 

0.50

1.10

1.30

1.07

 

 

 

 

0.55

1.04

1.40

1.04

 

 

 

 

0.60

1.00

1.50

1.00

 

 

 

 

0.65

0.96

1.60

0.97

 

 

 

 

0.70

0.93

1.70

0.94

 

 

 

 

0.75

0.90

 

 

 

 

 

 

0.80

0.87

 

 

 

 

 

 

2.Locate leaks using approved combustible gas detector, soap and water, or similar nonflammable solution. Do not use matches, candles, open flames, or other ignition source.

Figure 8: Recommended Gas Piping

10

Image 10
Contents Minuteman 81404025R13-1/07 Price $3.00Table of Contents Dimensional Drawing Pre-Installation Minimum Clearances to Combustible SurfacesIII. Water Piping and Trim II. Unpack BoilerDo not drop boiler. Do not bump boiler jacket against floor Page Internal Water Piping System Diagram IV. Domestic Hot Water Performance and Piping Domestic Hot Water RatingsGas Piping Rated InputFitting Equivalent Lengths Specific Gravity Correction FactorsGeneral Guidelines VI. Venting / Air Intake PipingComponent Vent/Air Intake LengthInstall Vent Connector Burnham Vent System ComponentsInstall Vent Pipe, Burnham Gasket-Less Vent System Install Vent Pipe, GeneralInstall Vent Pipe, Burnham Gasketed Vent System Horizontal Through Wall Vent Installation Burnham Gasketed Vent Joint DetailRecommended Horizontal Vent Installation Vertical Through Roof Vent Installation Horizontal Vent Pipe Wall PenetrationVertical Vent Installation Install Air Intake PipeWiring Diagram VII. ElectricalVIII. System Start-up Do not install an automatic fill valve with this boilerPrepare to check operation Operating Instructions Adjust gas input rate to boiler Check Boiler High LimitGas Flow Rate in Cubic Feet per Hour IX. Service Main Burners and Combustion Chamber LubricationBurner and Flueway Cleaning Differential Pressure Switch Settings Pilot Burner LocationAvoid Breathing Fiber Particulates and Dust Page Page Canopy/Blower Assembly Repair PartsHeat Exchanger Assembly Cerafelt Gasketing not depictedPage Page Base Assembly Page Page Jacket Assembly Domestic Water Tank Assembly Miscellaneous Trim and Controls Vent Accessory Carton Air Intake TerminalLimited Warranty