Mix 4 and Mix 5 Dial Settings
Dial Setting | Resolution (using 4x multiplier) |
| ||
1000 | 1000 ∝ m/pulse | (1mm) | Note: These resolutions | |
|
|
|
| are only available |
|
|
|
| with 4 edge |
|
|
|
| counting mode. |
500 | 500 | ∝ m/pulse | (0.5mm) |
|
100 | 100 | ∝ m/pulse | (0.1mm) |
|
50 | 50 | ∝ m/pulse | (0.05mm) |
|
10 | 10 | ∝ m/pulse | (0.01mm) |
|
5 | 5 | ∝ m/pulse | (0.005mm) |
|
ELGO Mix 5 series Magnetic Type
Encoder type: Non contact, magnetic, open type. Open scale linear encoders are used primarily where environmental conditions are clean, dry and free of oils. The magnetic encoder scale is susceptible to damage from magnetic fields. Great care should be taken to isolate the magnetic scale from magnets, static electricity, and electrical current.
Mechanical design: Magnetic scale with stainless steel protective cover, magnetic sensor unit, high flex twisted shielded cable. The magnetic linear encoder system features an integrated sensor and translator with a continuous marker pulse output. The marker pulse is sent every time the sensor passes the marker tape (maximum speed 0.1 m/second). Encoder is bonded to the stage surface with a double sided industrial adhesive tape. (DO NOT attempt to remove the scale from the stage surface, for this will permanently damage the encoder scale. Contact Baldor or an authorized distributor for assistance).
Maintenance: The encoder scale can be cleaned with soapy water or alcohol. Avoid chemicals such as acetone, MEK, and other solvents. The encoder magnetic scanning unit should be treated with great care as not to scratch or mar the external read head surface. If cleaning is required, the encoder read head surface can be cleaned with soapy water or alcohol. (Avoid submersion). Using a cotton swab, lightly wipe clean the contaminated surfaces. If removal of the encoder magnetic read head is required, consult with Baldor or an authorized distributor.
Wiring diagram: (for flying leads, high flex cable, 5.7mm diameter)
ML6004A00 5.7mm Diameter Cable
Color | Description | Function |
White | +5VDC | Encoder Power |
Black | 0VDC | Encoder GND |
Green | A+ | Incremental Signal |
Yellow | A– | Incremental Signal |
Pink | B+ | Incremental Signal |
Red | B– | Incremental Signal |
Brown | C+ | Incremental Signal |
Gray | C– | Incremental Signal |
| Shield | Shield (Connect to Earth Ground) |
Technical Data: |
| |
Encoder Type: | Quad digital output | |
Input power: |
| 5VDC, 200mA |
Output: |
| A/B quadrature and reference marks, differential line drive output |
Resolution: |
| 5.0, 10.0 micron |
Accuracy: |
| Resolution dependent |
Reference mark: | Continuous (bidirectional) |
MN1800 | Installation & Operation |