Baldor iMN1800 manual Mix 4 and Mix 5 Dial Settings Resolution using 4x multiplier

Page 44

Mix 4 and Mix 5 Dial Settings

Dial Setting

Resolution (using 4x multiplier)

 

1000

1000 m/pulse

(1mm)

Note: These resolutions

 

 

 

 

are only available

 

 

 

 

with 4 edge

 

 

 

 

counting mode.

500

500

m/pulse

(0.5mm)

 

100

100

m/pulse

(0.1mm)

 

50

50

m/pulse

(0.05mm)

 

10

10

m/pulse

(0.01mm)

 

5

5

m/pulse

(0.005mm)

 

ELGO Mix 5 series Magnetic Type

Encoder type: Non contact, magnetic, open type. Open scale linear encoders are used primarily where environmental conditions are clean, dry and free of oils. The magnetic encoder scale is susceptible to damage from magnetic fields. Great care should be taken to isolate the magnetic scale from magnets, static electricity, and electrical current.

Mechanical design: Magnetic scale with stainless steel protective cover, magnetic sensor unit, high flex twisted shielded cable. The magnetic linear encoder system features an integrated sensor and translator with a continuous marker pulse output. The marker pulse is sent every time the sensor passes the marker tape (maximum speed 0.1 m/second). Encoder is bonded to the stage surface with a double sided industrial adhesive tape. (DO NOT attempt to remove the scale from the stage surface, for this will permanently damage the encoder scale. Contact Baldor or an authorized distributor for assistance).

Maintenance: The encoder scale can be cleaned with soapy water or alcohol. Avoid chemicals such as acetone, MEK, and other solvents. The encoder magnetic scanning unit should be treated with great care as not to scratch or mar the external read head surface. If cleaning is required, the encoder read head surface can be cleaned with soapy water or alcohol. (Avoid submersion). Using a cotton swab, lightly wipe clean the contaminated surfaces. If removal of the encoder magnetic read head is required, consult with Baldor or an authorized distributor.

Wiring diagram: (for flying leads, high flex cable, 5.7mm diameter)

ML6004A00 5.7mm Diameter Cable

Color

Description

Function

White

+5VDC

Encoder Power

Black

0VDC

Encoder GND

Green

A+

Incremental Signal

Yellow

A–

Incremental Signal

Pink

B+

Incremental Signal

Red

B–

Incremental Signal

Brown

C+

Incremental Signal

Gray

C–

Incremental Signal

 

Shield

Shield (Connect to Earth Ground)

Technical Data:

 

Encoder Type:

Quad digital output

Input power:

 

5VDC, 200mA

Output:

 

A/B quadrature and reference marks, differential line drive output

Resolution:

 

5.0, 10.0 micron

Accuracy:

 

Resolution dependent

Reference mark:

Continuous (bidirectional)

MN1800

Installation & Operation 2-37

Image 44 Contents
Linear Motors MN1800Table of Contents Ii Table of Contents MN1800 Indicates a condition that can cause damage to equipment Limited WarrantyOverview Lifting, installing, operating and maintaining operations Installation, operation and maintenance of this equipmentDo not apply AC power before you ensure that all grounding Attempt to install operate or maintain this equipmentReceiving StorageUnpacking HandlingGeneral Information MN1800 Mounting a Stage to the Machine Base and Payload To Stage Clean RoomLocation Lmac Connection Diagram Lmac Linear Induction MotorLmbr Series Brush DC Linear Servo Motor Lmbl Series Brushless Linear Iron Core Servo Motor InstallationAlternate Installation Refer to Figure Motor Cable Hall Cable Limit Cable AY1763A00 Leadwire ConnectionWire Color Modular Magnet Track Installation Brushless Linear Iron Core Servo Motor Modular Magnet Track Hall Cable Limit CableLmcf Series Brushless Linear Cog Free Servo Motor Air Gap SpacingLmnc Moving Coil Type Pin# ColorLmnm Moving Magnet Type Non Commutated DC Linear Servo Motor Switching Lmpy Series Polynoid Linear Motor Holding OptionSingle Holding Double HoldingLeadwire Connection Motor Cable Signal Name Wire ColorLmpy Series Polynoid Linear Motor Holding OptionAdjust Air Gap MaintenanceAY0165A00 Leadwire Connection 9 pin to flying leads Lmss Series Linear StepperAir Bearing Motor Cleaning the Forcer and Platen Installation Mounting the Forcer on the PlatenLmss Series Removing the Forcer from the PlatenLmds Series Dual Axis Linear Stepper Motor Items Required but not IncludedUnpacking Stage Specifications DisclaimerPositioning Stages Stage specifications LSE Series Enclosed Position Stage General DescriptionConstruction Bearing typeAY1779A00 LSE with Renishaw Encoder RGH24 Flying Leads LD9124A00 Limit and Home, Axis 1, Internal Pin# Color LD9125A01 Limit only Color Pin# DescriptionLD9137A01 Limit only Color Pin# Description LSE Stage Connector Locations LSC Series Cross Roller Position Stage General Description AY1775A00 Leadwire Connection for LinDrive 15 pin LD9125A02 H-Limit and Home Color Pin# Description LSS Series Single Bearing Position Stage AY1759A00 Renishaw RSF EncoderAY1801A00 Stages with Renishaw Encoder RGH22 Flying Leads AY1802A00 Stages with Renishaw Encoder RSF Flying LeadsLD9114A00 Leadwire Connection LD9103A00LXS Connections Female LinDrive Connections Male Motor / Limit Connections Pin Circular Connector Male Pin D Sub MalePin D Sub Female LSX Leadwire Connection Limit Switch Pigtails LD9119A01 Color Pin# DescriptionLD9119A02 Color Pin# Description LD9137A02 Limit and HomePin Encoder Connector Pin Encoder ConnectionsBearing Maintenance Recirculating Bearing Rail And Block Cross Roller Type BearingEncoder Maintenance Technical DataRSF Series MSA6x Enclosed Type Color Description Function RSF Series MS6x Open Type Glass Scale Renishaw RGH22 series Open Type Metal Scale Renishaw RGH22 series Open Type Metal Scale Specifications Associated ComponentsEncoder Head Output Connector Pin Assignment Elgo Mix 4 series Magnetic TypeMix 4 and Mix 5 Dial Settings Resolution using 4x multiplier Elgo Mix 5 series Magnetic TypeEncoder Specifications RequirementsCables and Cable Chain Procedures Additional Cables Baldor Electric Company  Baldor Electric Company MN1800 01 C&J1500