Bosch Appliances WR430-7K manual Vent Installation, Electrical Wiring

Page 9

Bosch POWER VENTING SYSTEM

Figure 2

36”

7

 

2

 

36”

72”

REGULATOR VENT

ELECTRICAL WIRING:

1.The electrical contact ratings are as follows:

______ 1/10 HP at 120 VAC

______ 3 Amps (full load) at 120 VA

2.Provide switched plug receptacle to accommodate Bosch grounded plug.

3.Make certain the power source is adequate for the fan motor requirements.

VENT INSTALLATION

1.Choose approved terminal location

2.Cut vent terminal opening through outside wall - Refer to installation instructions supplied with termination.

3.Install vent terminal by fastening from outside with 4 screws and caulking around flange edge. Check that optional flapper moves freely if applicable.

4.Install 4” venting materials and secure all joints with a minimum of four screws for each joint. Please note that wherever possible use continual lengths of pipe to reduce the number of joints.

5.Seal all positive vent pipe and elbow joints between Bosch unit and vent terminal with high temperature silicone and/or hi temperature aluminum tape following manufacturer’s instructions (i.e. always push silicone ahead of nozzle)

6 720 606 599

9

Image 9
Contents What to do if YOU Smell GAS Instantaneous gas water heaterFeatures Unpacking the Bosch WR430-7K HeaterNAT. GAS Propane Dimensions Location ElectricalAIR Requirements Mounting ClearanceGeneral Information IntroductionGeneral Venting Information Sizing & DistancesApproved Venting Materials General Code RequirementsVent Terminal Installation Electrical Wiring Vent InstallationOperation and Checking the Draft Vent InstallationMaintenance Water Connections Drip TrayGAS Connections Relief ValveFilling Service HintLighting and Operating Instructions To Turn OFF GAS to ApplianceTemperature Regulation High Temperature Limit SwitchPressure Regulation Characteristic Pilot Flame Maintenance and ServiceTrouble Shooting Adjusting ScrewNo Spark AT the Pilot Pilot Sparks Continuously with No Water Running Pilot Lights but Burners Will not Come onMain Burners GO OUT During HOT Water USE Water is TOO HOT Water is not HOT EnoughHOT Water Tempe Ratur E Fluctuates Diagram of WR430-7K 720 606 Interior Components Diagram Parts List WR430 Interior Components Diagram and Parts List Page Chauffe-eau instantané, à gaz Principe de fonctionnement Déballage DU CHAUFFE-EAU Bosch WR430-7KDimensions Lieu Dinstallation Alimentation ÉlectriqueDemande Dair Avertissement Dégagements DE SéparationMontage Information Générale IntroductionPrescriptions Générales DES Codes Matériaux Approuvés Pour LE Circuit DE DéchargeInstallation DE LA Bouche DE Décharge Câblage Électrique Installation DU Système DE DéchargeContrôle DU Tirage Utilisation ET Contrôle DU TiragePoints dinspection EntretienRaccordement AUX Canalisations Deau Plateau DE RécupérationRaccordement À LA Canalisation DE GAZ Soupape DE SurpressionRemplissage Allumage ET UtilisationInterruption DE L’ALIMENTATION EN GAZ DU CHAUFFE-EAU Thermostat DE Sécurité «HAUTE TEMPÉRATURE» Régulation DE LA PressionDispositif de la flamme de veille PAS D’ÉTINCELLES Pour LA Flamme DE Veille DépannageFlamme DE Veille ALLUMÉE, Mais LE Brûleur NE ’ALLUME PAS Production Constante D’ÉTINCELLES, Sans Circulation D’EAUEAU Trop Chaude Température DE L’EAU InsuffisanteFluctuation DE LA Température DE L’EAU Chauffe-eau WR430-7K 720 606 Composants Internes DU CHAUFFE-EAU WR ET Liste DES Pièces Composants Internes ET Liste DES Pièces