EXTERNAL INSPECTION AND CLEANING
Cleaning the Air Intake Chamber Screen:
•At least twice annually the air intake chamber screen should be inspected for any dust or debris that may have accumulated on the louvers.
NOTE: If the water heater is located in an area that is subjected to lint, pet hair or dirt, it may be necessary to check the air intake chamber screen more frequently.
•Use a vacuum cleaner with a hose attachment to remove any dust or debris that may have accumulated on the screen.
Figure 24.
Air Intake Chamb
e![]()
r![]()
![]()
Screen ![]()
![]()
![]()
![]()
Cleaning the Combustion Chamber and Air Diverter Assembly:
•Follow procedure outlined in “Removing Inner Door/Manifold/Burner Assembly”, page 41.
•Use a vacuum cleaner/shop vac to remove all loose debris in the combustion chamber. Use compressed air to clear any dust or debris that may have accumulated on the air diverter assembly.
•Reassemble following the procedure under “Installing Inner Door/Manifold/Burner Assembly”, page 42.
Figure 25. |
|
INNER DOOR/ |
|
MANIFOLD/BURNER | COMBUSTION |
ASSEMBLY | |
| CHAMBER |
INSTALL | AIR DIVERTER |
ASSEMBLY | |
| |
REMOVE |
|
24