Craftsman 139.18595 Test the Safety Reversal System, Test The Protector System, Adjust

Page 29

ADJUSTMENT STEP 3

Test the Safety Reversal System

TEST

With the door fully open, place a 1-1/2" (3.8 cm) board (or a 2x4 laid flat) on the floor, centered under the garage door.

Operate the door in the down direction. The door must reverse on striking the obstruction.

ADJUST

If the door stops on the obstruction, it is not traveling far enough in the down direction. Increase the DOWN limit by turning the DOWN limit adjustment screw counterclockwise 1/4 turn.

NOTE: On a sectional door, make sure limit adjustments do not force the door arm beyond a straight up and down position. See the illustration on page 25.

Repeat the test.

When the door reverses on the 1-1/2" (3.8 cm) board, remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment.

If the unit continues to fail the Safety Reverse Test, call for a trained door systems technician.

IMPORTANT SAFETY CHECK:

Test the Safety Reverse System after:

Each adjustment of door arm length, limits, or force controls.

Any repair to or adjustment of the garage door (including springs and hardware).

Any repair to or buckling of the garage floor.

Any repair to or adjustment of the opener.

ADJUSTMENT STEP 4

Test The Protector System®

Press the remote control push button to open the door.

Place the opener carton in the path of the door.

Press the remote control push button to close the door. The door will not move more than an inch (2.5 cm), and the opener lights will flash.

The garage door opener will not close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed).

If the opener closes the door when the safety reversing sensor is obstructed (and the sensors are no more than 6" (15 cm) above the floor), call for a trained door systems technician.

WARNING

Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

Safety reversal system MUST be tested every month.

If one control (force or travel limits) is adjusted, the other control may also need adjustment.

After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on the floor.

1-1/2" (3.8 cm) board (or a 2x4 laid flat)

WARNING

Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

Safety Reversing Sensor

Safety Reversing Sensor

29

Image 29 Contents
Garage Door Opener Introduction Table of ContentsTools needed Preparing your garage doorSectional Door Installation Sectional Door InstallationsPlanning Trolley Stop Bolt TrolleyONE-PIECE Door Without Track ONE-PIECE Door InstallationsONE-PIECE Door with Track Trolley Stop BoltKeyless Entry Hanging Brackets Straight Door Arm Section Carton InventoryHardware Inventory Assembly HardwareInstallation Hardware Assemble the Rail & Install the Trolley Assembly StepHole on TOPTapered End Clip Tapered End RailFasten the Rail to the Motor Unit Install the Idler PulleyInstall the Chain/Cable Tighten the Chain InstallationDetermine the Header Bracket Location Installation StepCeiling Header Bracket Installation Install the Header BracketWall Header Bracket Installation Header Wall Header Bracket Idler Pulley Garage Door Attach the Rail to the Header BracketHeader Bracket Mounting Hole Existing Clevis Pin Spacer Opener Carton or Temporary SupportSectional Door or ONE-PIECE Door with Track Position the OpenerRail Door 2x4 is used to determine From ceilingStructural Hang the OpenerSupports Bolt 5/16-18x7/8 Nut 5/16-18 Lock Washer 5/16To release wire, push Install the Door ControlStrip wire 7/16 11 mm Tab with screwdriver tipRelease Tab Install the LightsAttach the Emergency Release Rope and Handle Electrical Requirements Important Information about Safety Reversing Sensor Install The Protector SystemSensor Beam Invisible Light Beam Cm max Protection AreaGarage door track installation preferred Installing the BracketsWall installation Floor installation FigureAligning the Safety Sensors Mounting and Wiring the Safety SensorsTroubleshooting the Safety Sensors Quick-Connect TerminalsSectional Doors Fasten the Door BracketHeader Wall 2x4 ONE-PIECE Doors Sectional Doors only Connect Door Arm to Trolley TrolleyTrolley Emergency Release DoorHandle Bracket Straight Door ArmALL ONE-PIECE Doors Adjustment procedures, FigureAssemble the door arm, Figure Connect the door arm to the trolleyAdjust the UP and Down Travel Limits Adjustment StepIf door does not open at least 5 feet 1.5 m If the door does not close completelyHOW and When to Adjust the Forces Adjust the ForceTest the Down close force Test the UP open forceAdjust Test the Safety Reversal SystemImportant Safety Check Test The Protector SystemActivate your opener with any of the following Using Your Garage Door OpenerOperation Lock feature Light featurePremium Control Console Disconnect the TrolleyOnce a Month Care of Your OpenerTwice a Year Once a YearMy door will not close and the light bulbs blink Having a PROBLEM?Symptom Motor unit doesn’t operate Symptom LED is not lit on door controlUsing the Learn Button Using the Premium Control Console To Add or Reprogram a Hand-held Remote ControlProgramming To Erase All Codes From Motor Unit MemoryTo set a temporary PIN To Add, Reprogram or Change a Keyless Entry PINTo change an existing, known PIN Rail Assembly Parts Repair PartsKEY Part Description Not ShownBracket, bearing assembly, RPM Sensor Motor Unit Assembly PartsComplete with Spring washer Complete with Motor, wormWarranty AccessoriesParts & Service Sears WarrantyGet it fixed, at your home or ours Le vérifier et le régler périodiquement Pour un bon fonctionnement en touteSécurité de cet ouvre-porte de garage Revue des symboles de sécurité et des mots de signalement Accessoires Garantie Pièces de réparation et serviceIntroduction MontageOutils nécessaires Préparation de votre porte de garagePour prévenir d’éventuelles Blessures Graves ou Porte articulée Porte rigidePose DE Porte Articulée PlanificationPose DE Portes Articulées Pose DE Porte Rigide Planification SuiteEt le bas de la porte ne doit De porte Porte de DurgenceInventaire de la boîte d’emballage Fixations Pour LA Pose Inventaire des fixationsFixations Pour LE Montage Montage du rail et pose du chariot Montage 1re OpérationMontage 3e Opération Montage 2e OpérationFixation du rail au moteur Pose de la pouliePose de la chaîne et du câble Montage 4e OpérationTension de la chaîne Montage 5e OpérationPose 1re Opération Déterminer l’emplacement du support de linteauPose du support de linteau Pose 2e OpérationPose DU Support DE Linteau AU MUR Pose DU Support DE Linteau AU PlafondFixation du rail sur le support de linteau Pose 3e OpérationPositionnement de louvre-porte Pose 4e OpérationPorte Articulée OU Porte Rigide Avec Guides Porte Rigide Sans GuidesAccrochage de louvre-porte Pose 5e OpérationPose 6e Opération Pose de la commande de portePlacer le fil de l’antenne comme montré Raccordements à une serrure à clé extérieurePose 8e Opération Pose 7e OpérationPose des ampoules Languette de dégagementExigences électriques Pose 9e OpérationLouvre-porte doit obligatoirement être mis à la terre Reposer le couvercleFaisant face à la porte depuis lintérieur du garage Pose 10e OpérationPose du Système Protector Pose DES Supports Pose aux guides de la porte de garage mode préférable’assurer que l’ouvre-porte est hors tension Pose murale etDépannage DES Détecteurs Inverseurs DE Sécurité Montage ET Câblage DES Détecteurs InverseursAlignement DES Détecteurs Inverseurs Portes Articulées Pose 11e OpérationFixation du support de porte Pour une porte sans cadre exposé Portes RigidesDe la porte Porte Articulée Seulement Pose 12e OpérationFixation de la biellette au chariot Assemblage des biellettes, Figure Pour Toutes LES Portes RigidesMéthodes de réglage, Figure De courseRéglage des courses d’ouverture et de fermeture Réglages 1re OpérationComment ET Quand Régler LES Courses Si la porte ne souvre pas dau moins Pieds 1,5 mRéglage de la force Réglages 2e OpérationComment ET Quand Régler LES Forces Vérification de la force de fermeture DownRéglages 4e Opération Réglages 3e OpérationEssai du système d’inversion de sécurité Essai du Systéme ProtectorActionner l’ouvre-porte suivant l’une des méthodes ci-après Utilisation de votre ouvre-porte de garageOu un 2 x 4 posé à plat sur le sol Ouverture manuelle de la porte Utilisation de la commande de porte muralFonction déclairage Fonction de verrouillagePériodicités D’ENTRETIEN Réglages DE Course ET DE Force LA Pile DE LA TélécommandeUne fois par mois Deux fois par annéeLe moteur de l’ouvre-porte ronfle brièvement Mes télécommandes ne font pas fonctionner la porte’éclairage ne s’éteint pas quand la porte est ouverte Symptôme Le moteur ne fonctionne pas Court-circuit de la commande de porte ou du filPour effacer tous les codes de la Mémoire du moteur Pour ajouter ou reprogrammer une télécommande à mainTélécommande à trois fonctions Pour définir un NIP temporaire Pour modifier un NIP connu, existantPièces pour la pose Pièces d’assemblage du railRÉF Pièce Désignation NON IllustrésRetenue d’interrupteur de fin de Comprend Rondelle de108D67 Diffuseur Les étiquettes 30B532 Condensateur 1/2HP NON IllustréSears ’entremise des Pièces et ServiceDisponible uniquement par LE-FOYERMD