Henny Penny EEE-143, EEE-141 warranty Info Button Stats Filter Button Stats, Actual Oil Temperature

Page 38

Model EEE-141,142, 143, 144

3-19. INFO BUTTON STATS

3-20. FILTER BUTTON STATS

Actual Oil Temperature

1. Press and the actual oil temperature shows in the display, for each vat.

Set-point Temperature

2. Press twice and SP shows in the display, along with the set-point (preset) temperature of each vat.

Recovery Information for each Vat

1. Press

3 times and REC shows in the left display and

the recovery time that oil temperature went from 250°F

(121°C) to 300°F (149°C) shows in the right display. For

example,

REC

5:30 means it took 5 minutes and

30 seconds for the oil temperature to recover to 300°F (149°C) from 250°F (121°C).

If no buttons are pressed within 5 seconds in any of stats modes, the controls revert back to normal operation.

Cook Cycles Remaining before Filtering

 

1. Press and release either

button and the left display

shows “COOKS REMAINING” and the right display shows

the number of cook cycles before the next auto filter. For

example,

REMA INING

3

6

 

means after 3 more cook cycles on the left vat, the controls asks the operator if they are ready to filter or not. But, 6 more cook cycles remain on the right vat.

Time and Date

2.Press either twice and ‘FILTERED” shows in the diplays, along with the time-of-day and date of the last filter.

3-25

309

Image 38
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Introduction Proper Care AssistanceAVOIDED, will Result in Death or Serious SafetyHazardous Situation WHICH, if not InjurySafety Unpacking Instructions InstallationIntroduction Leveling the Fryer Selecting the FryerLocation Ventilation of Fryer Electrical Requirements For Equipment with CE Mark onlyElectrical Requirements Dimensions Auto-Lift FryersOperation Operating Components Refer to explanations on the next pagesDescription Function Operating Components Description Function JIB SET-UP Mode International DD-MM-YYFilling or Adding OIL Fill POT from BulkMorning START-UP ProceduresExtreme Moisture Content Into Do not OVERLOAD, or Place Product withIdle Mode OIL Guardian Auto Top-Off Manual Top-OffRemoving/Cleaning Reservoir Model EEE-141 OIL Filling Oil Reservoir1009 Filter Error Daily Filtering Daily Filtering Press √ button for YES if another rinse is needed, otherwise Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing Cleaning BasketCleaned periodically RestCLEAN-OUT Mode CLEAN-OUT CLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Recovery Information for each Vat Actual Oil TemperatureSet-point Temperature Info Button Stats Filter Button StatsPreventive MaintenanceProcedure Frequency ScheduleInformation Mode Information Mode DetailsDetails Function Display EXDaily Stats Operational info of fryer for last 7 days NEW OIL Review USAGEaccumulated info since the data was reset Assign Button Product Program Mode Modifying Product SettingsChange Product Names Modifying Product Mixed Filter Tracking Level 2 Programming Special Program Mode SP-8CLanguage SP-2 Audio Volume SP-4Degrees Fahrenheit or Celsius SP-1 System Initialization SP-3Special Program Audio Tone SP-5 ModeIdle Mode Enabled SP-7 Liquid or Solid Cooking Oil Used SP-6Mixed Special Program ModeFilter Tracking Mode SP-8 Filter Tracking Mode SP-8 Clean-Out Temperature SP-12 Polish Duration SP-9 ModeClean-Out Time SP-11 Cooking Indicator SP-15Engery Save Mode SP-18 2nd Language SP-16 Mode2nd Volume SP-17 Fryer Type SP-19Bulk Oil Disposal SP-23 Autolift Enabled SP-21 ModeBulk Oil Supply SP-22 Serial Number Log SP-24Longer Fill Time SP-28 Usage Code Change SP-26Dispose Requires Code ? SP-27 Let User Exit Fill SP-29609 Troubleshooting Trouble Shooting Guide Problem Cause CorrectionTrouble Shooting Guide Error Codes Display Cause CorrectionError Codes Display Cause Correction Cord BreakerPage Henny Penny Corporation Box Eaton,OH Toll free in USA