Model
| In the event of a control system failure, the digital display shows an | |
|
| error message. The message codes are shown in the DISPLAY |
|
| column below. A constant tone is heard when an error code is |
|
| displayed, and to silence this tone, press any button. |
|
|
|
DISPLAY | CAUSE | CORRECTION |
|
|
|
Control board | Turn switch to OFF position, then turn switch back to ON; | |
| overheating | if display shows |
|
| check the louvers on each side of the unit for obstructions |
|
|
|
Oil | Turn switch to OFF position, then turn switch back to ON; | |
| overheating | if display shows |
|
| probes should be checked |
|
|
|
Temperature | Turn switch to OFF position, then turn switch back to ON; | |
| probe open | if display shows |
|
| checked |
|
|
|
Temperature | Turn switch to OFF position, then turn switch back to ON; | |
| probe shorted | if display shows |
|
| checked |
|
|
|
Highlimit | Reset the high limit by using a small screwdriver orAllen | |
|
| wrench gently pushing it into the hole in the heating element |
|
| hinge; if high limit does not reset, high limit may need be replaced |
|
|
|
Drain switch | Make sure drain knob is completely | |
|
| have drain switch checked |
|
|
|
Left level sensor open | Turn switch to OFF position, then turn switch back to ON; | |
Right level sensor open | if display still indicates a failed sensor, have the connectors checked | |
Both level sensors open | at the control board; have sensor checked & replace if necessory | |
|
|
|
209 |
|