Manitowoc Ice QF2300, QF0800, QC0700, QF0400 manual Condenser Air Baffle, Leveling Leg and Foot

Page 16

Installation Instructions

Section 2

 

 

Leveling the Ice Storage Bin

1.Screw the leveling legs onto the bottom of the bin.

2.Screw the foot of each leg in as far as possible.

!Caution

The legs must be screwed in tightly to prevent them from bending.

3.Move the bin into its final position.

4.Level the bin to assure that the bin door closes and seals properly. Use a level on top of the bin. Turn each foot as necessary to level the bin.

5.Inspect bin gasket prior to ice machine installation. (Manitowoc bins come with closed cell foam gasket installed along the top surface of the bin.)

6.Install ice machine on bin.

NOTE: An optional caster assembly is available for use in place of the legs. Installation instructions are supplied with the casters.

THREAD LEVELING

LEG INTO BASE OF

CABINET

THREAD ‘FOOT’ IN AS

FAR AS POSSIBLE

SV1606

Leveling Leg and Foot

Condenser Air Baffle

(QC700/QF800 Air-Cooled Ice Machines Only)

The air-cooled baffle prevents condenser air from recirculating. To install:

1.Remove the back panel screws next to the condenser.

2.Align the mounting holes in the air baffle with the screw holes and reinstall the screws.

AIR

BAFFLE

SCREWS

SV1607

Air Baffle

2-6

Part Number 000002688

Image 16
Contents Installation Use and Care Manual Read These Before Proceeding Personal Injury PotentialTable of Contents Table of Contents Section Ice Machine OperationTable of Contents Section Ice Machine Sequence of Operation Section Before Calling ServiceTable of Contents How to Read a Model Number AccessoriesModel Numbers Remote Condensing UnitGeneral Information Section Model/Serial Number Location Model/Serial Number Location Ice Machine Model NumberCommercial Warranty Coverage General Information Section Ice Machine Dimensions QF400 AIR Cooled ICE MachineQC700/QF800 Water Cooled ICE Machine QC700/QF800 AIR Cooled ICE MachineQF2300 Head Section and RFC2385 Remote Condensing Unit Bin Model Dimension a Dimension B Inch 56 CM ICE Storage Bins Inch 130 CM ICE Storage Bins Inch 76 CM ICE Storage Bins B970Bin Model Dimension a Width Dimension B Height Inch 76 CMSection Installation Instructions Location of Ice Machine Ice Machine Head Section Clearance RequirementsIce Machine Heat of Rejection Location of Remote Condensing UnitCondenser Air Baffle Leveling Leg and FootQC700/QF800 Air-Cooled Ice Machines Only Air BaffleSection Installation Instructions Electrical Service For United Kingdom Only Installation Instructions Section Electrical RequirementsIce Machine Head Section QC700C/QF800C ICE Machine Head /1/50 QC700C/QF800C ICE Machine Head /1/60 or 208-230/1/60QF2300 ICE Machine Head /60/1 RFC2385 Remote Condensing Unit 208-230/1/60 Section Installation Instructions Water Supply and Drains Cooling Tower Applications Water-Cooled ModelsPotable Water Supply Potable Water Inlet LinesTypical Water Supply Drain Installation Installation Instructions SectionWater Supply and Drain Line SIZING/CONNECTIONS Usage with NON-MANITOWOC Condensing Units QF2300/RFC2385 onlyFactory Equipment Refrigeration Amounts Line SET Length Line SET Rise or DropRoof/Wall Penetration Route Refrigeration TubingService Loop Supplied service loop is an installation requirementSuction Line OIL Traps Manitowoc S-Trap KitConnect The Line Set To The Ice Machine Head Section Connecting the line setConnect The Line Set To The Remote Condensing Unit Open The Valves Prior To Starting The Ice Machine Torque Value’sOpen Receiver Service Valve Leak Check The Refrigeration SystemInsulation Requirements Suction Liquid Min. Insulation LineSuction Shut Off Valve Insulation Typical Remote System Installation Section Installation Instructions Installation Checklist Remote AIR-COOLED onlyPotential Personal Injury Situation Component Identification ICE Machine Head SectionQC700/QF800 QF400Ice Machine Operation Section QF2300Section Ice Machine Operation Operational Checks Water Level CheckHeavily Scaled Cleaning Procedure Cleaning/Sanitizing ProcedureExterior Cleaning Cleaning the Condenser Air-Cooled CondenserSelf-Contained Air-Cooled Filter Straighten Bent Condenser FinsMANITOWOC’S Cleaning Technology Model Amount of CleanerPreventative Maintenance Cleaning Procedure QF400 Amount of Water Amount of Cleaner CLEANING/SANITIZING Procedure QC700/QF800/QF2300Amount of Water Amount of Sanitizer CLEANING/SANITIZING Procedure QF400 Mix Cleaner and Water Use Ice machine cleanerCleaner OnlySolution Type Removal of Parts for CLEANING/SANITIZINGMixed With Water Level Probe Removal QF2300 Water Reservoir Cover RemovalQC700/QF800 Shown Water Level Probe RemovalQF2300 Shown Float Valve Removal Water Reservoir Removal QC700/QF800 Shown Ice Diverter RemovalIce Chute Removal Bin Door Removal Cabinet RemovalDump Valve Disassembly Water Dump ValveWater Cooled Condensing Unit Pry Open the Water Regulating ValvePrior to START-UP QF400/QC700/QF800Flush Sequence in the ICE Position Ice Machine Sequence of Operation Section QF2300 Checklist Problem Possible Cause To CorrectReset Procedure Safeguard Indicator Lights Before Calling Service Section Safeguard FeatureStandby Mode Analyzing Why SafeGuards May Stop the Ice Machine No Water ChecklistSafeguard Modes Possible Problem List Corrective Action ListGear Motor Speed Checklist Before Calling Service SectionGear Motor Speed Temperature is Too High or Low QF400/QC700/QF800 Temperature Sensor ChecklistThis page Intentionally Left Blank Page Manitowoc ICE, INC