Installation Preparation
PREPARE ELECTRICAL WIRING
WARNING
FOR PERSONAL SAFETY: Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance.
Electrical Requirements
•This appliance must be supplied with 120V, 60 Hz. and connected to an individual properly grounded branch circuit, protected by a 15- or
•Wiring must be
•If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.
Grounding Instructions—Permanent Connection
This appliance must be connected to a grounded metal, permanent wiring system, or an
Grounding Instructions—Power Cord Models
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current . This appliance is equipped with a cord having an
WARNING
The improper connection of the equipment- grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or service representative if you are in doubt that the appliance is properly grounded.
| Alternate |
| Receptacle |
| Location |
| 18" |
| |
18" | Hole (Max.) |
| |
6" | 6" |
| 3" from |
| Cabinet |
Receptacle | 24" from |
Location Area | Wall |
Ground White
Figure E
Black
For models equipped with power cord: Do not modify the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified technician.
Cabinet Preparation and Wire Routing
•The wiring may enter the opening from either side, rear or the floor within the shaded area dimensioned in Figure A and illustrated above.
•Cut a
•NOTE: Power cords with plug must pass through a separate hole.
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher.
•For cable direct connections the cable must be routed as shown in Figure E. Cable must extend a minimum of 24" from the rear wall.
•For power cord connections, install a
6