Miele KM 326G manual For Canada only, Gas pressures for Canada, Nominal rating natural gas 4˝

Page 16

For Canada only

The gas connection must be made in accordance with the local codes, or in absence of local codes, with the current CAN/CA B 149.1 and .2 Inst.

Gas pressures for Canada

Manifold pressure:

natural gas 4˝ water column

liquid propane gas 10˝ water column

Nominal rating natural gas 4˝ 1)

Burner

high setting

low setting

 

kW

Btu/hr

kW

Btu/hr

 

 

 

 

 

high-speed burner

2.7

9200

0.35

1200

super high-speed burner

3.4

12000

0.45

1500

2-zone wok burner

4.0

14000

0.17

580

 

 

 

 

 

Nominal rating LP gas 10˝ with conversion kit 1)

Burner

high setting

low setting

 

kW

Btu/hr

kW

Btu/hr

 

 

 

 

 

high-speed burner

2.0

7000

0.40

1300

super high-speed burner

2.7

9200

0.50

2000

2-zone wok burner

3.3

11200

0.18

600

 

 

 

 

 

Important

a.The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of this system at test pressures in excess of 1/2 psi (3.5 kPa).

b.The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

Warning

The base of the hob will become hot. The gas connection used must comply with the relevant national and local regulations.

Important

When the gas hob has been installed, it is essential to check the main cable is not in contact with hot parts of the appliance, otherwise temperature damage to the cable could occur.

1)Important

This appliance with the orifices as delivered for natural gas or LP gas by the manufacturer is suitable for use till 2000 feet. By installation above 2000 feet contact your distributor or Miele USA/Canada and ask for a replacement set with orifices suitable for your altitude.

Change the orifices as written in the instructions of the manual.

14

Image 16
Contents T . n r 2 2 9 2 0 / T 9 1 7 0 1 B Mode demploi du kit de conversion AH 102 C4U English FrançaisPage Safety control Burner ring General MarkingControl knobs with marking Burner capPage Important notes for the user AdviceBefore starting check Lighting and adjusting Gas burnersHigh-speed and super high-speed burners Zone super high-speed wok burner Outer ringHow to use gas burners Place the pot over the pot support fitted above the hobMake sure the trivet is securely fixed to the pot support ˝ 50 mm between the pot and a heat-sensitive worktopAre best done on the super high-speed wok Burner Cooking in comfortMaking sauces Keeping food hot Cooking through/simmering Cleaning and maintenance Tab IndentationCont Appliance Troubleshooting Problem Cause Solution Burner does not burn wellIgnition sparks but burner Does not igniteElectrical circuit diagram Electrical connection This appliance must be groundedFor USA only Gas pressures for USAGas pressures for Canada For Canada onlyNominal rating natural gas 4˝ Building-in dimensions Clearance above and around the appliance Wall strips must be heat-resistantBuilding-in Place the hob in the cut-out. Check thatAir inlets at the back of the hob are clear Secure the hob in position. The bracketsPage Safety Instructions Conversion kit Type number AH 102 C4UPart Conversion instructionsDisassembly Conversion instructionsFor future use IgniterLocations of injectors and minimum adjustment screws Pressure regulator conversionPurposes. Check gas pressure. Permitted High speed and super high speed burner ConversionWok burner outer ring conversion Wok burner inner ring conversionHand side of the wok burner body a WayTwo 12 mm wrenches are needed to separate the fittings Reference tableAssembly Minimum adjustment screwsThis concludes conversion. The hob can now be reassembled Installing appliance Testing converted applianceWarranty and service Technical details Model number KM 326G Gas sourceEnergy source Overall wattage, electricity Total burnerrate Natural gasPage