Alto-Shaam AR-6G manual Ve n til a tion instructions

Page 10

I n s t a l l a tio n

ve n til a tion instructions

D a n G e r

Installation, air adjustment and/or service work must be in accordance with all local codes and must be performed by a certified service technician qualified to work on gas appliances.

An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. When writing refer to NFPA No. 96.

1.A single gas appliance requires a minimum of 32 CFM make-up air for natural and propane gas. Kitchen ventilation must include a provision for an adequate flow of fresh air for gas combustion and to prevent a negative-pressure condition. The rear of the appliance provides air supply access for gas combustion and must be kept clear at all times. DO

NOT obstruct or restrict ventilation nor the air flow required to support combustion.

2.DO NOT obstruct the flow of the exhaust flue at the top of the appliance. It is especially critical that gas supply piping and electrical support cord and/or receptacle be routed away from the path of the hot combustion fumes.

c a U t I o n

To prevent malfunction or cause negative back draft, DO NOT obstruct exhaust flues or attach any flue extension that will impede proper burner operation.

3.Make certain the appliance installation maintains adequate air ventilation to provide cooling for electrical and gas components. The area around the appliance should be clear of any obstructions which might retard the flow of cooling air. Failure to observe this caution may result in damage to the components and will void the warranty.

W a r n I n G

Inadequate ventilation, or failure to ensure an adequate supply of fresh air will result in a high ambient temperature at the sides of the appliance. An excessive ambient temperature can cause the thermal- overload protection motor to trip resulting in severe damage to the cooling fans.

4.This appliance cannot be direct vented.

5.Install the appliance under a ventilation hood meeting all applicable code requirements. Combustion fumes must be vented in accordance with local, state, or national codes.

D a n G e r

FAILURE TO VENT THIS APPLIANCE PROPERLY MAY BE HAZARDOUS TO THE HEALTH OF THE OPERATOR.

Equipment damage, operational problems and unsatisfactory baking performance may also be the consequence of improper venting. Any damage sustained by a failure to properly vent this oven are not covered under warranty.

c a U t I o n

DO NOT uSE CIRCulATING FANS

ON ThE FlOOR. FlOOR FANS WIll

AFFECT BuRNER OpERATION.

Ventilating hoods and exhaust systems shall be permitted to be used to vent appliances installed in commercial applications.

Where automatically operated appliances are vented through a ventilating hood or exhaust system equipped with a damper or with a power means of exhaust, provisions shall be made to allow the flow of gas to the main burners only when the damper is open to a position to properly vent the appliance and when the power means of exhaust is in operation. IN

ACCORDANCE WITH NFPA 54 COMMONWEALTH OF MASSACHUSETTS ONLY.

AR-6G Rotisserie Operation & Care Manual • 8

Image 10
Contents Operation Maintenance USAN G e r L I V e r y P a c K I n GSafety proceDUres anD precaUtIons R n I n GCommon specifications AccessoriesC h nical specifications Dimensions h x w x dSite Installation Technical componentsVentilation Requirements Installation Codes & StandardsStandard for GAS Food Service Equipment Positioning on SitePositioning Requirements Ve n til a tion instructions ElectrIcal GroUnDInG InstrUctIons E c t ric a lAVertIssement Directives Air supply AIR AdjustmentsReplace orifices as shown in chart AIR SupplyGAS Pressure Chart Gas specificationsInstallation Requirements Technical SpecificationsGAS Intake Gas pIpInG mUst neVer be InstalleD to rUn UnDer the bUrner Securing Electrical Access CoverNeVer Use an open flame to leaK test Leak testingGas exhaust Ignition systemRecommended Lighting Sequence Burner lighting instructionsGAS Flame Patterns To Light the BurnersN t r o l s Door catchA C E M E N T & Adjustment of Spits NeVer Use or place alUmInUm foIl In the applIanceCooking time Additional Product Roasting TimesEq u ipment care Daily cleaningWarranty Becomes Void if Appliance is Flooded SeVere DamaGe or electrIcal haZarD coUlD resUltCleaning & reseasoning cast iron tiles A ng ing of light bulbsGAS Circuit Oub l e s h o o ting guideDefect Observed Possible Cause Remedy Electrical Burner orifices are cloggedFull assembly Front view Description QTYFinal floor assembly Front view Final floor assembly Back viewFinal floor assembly Front & Back view Door HingeMotor mount assembly Assembly InstructionsTop assembly GLASS, LampBottom Assembly Gas plumbing assemblyBottom Side PANEL, Left S/S Bulb replacement instructions AR-6G Rotisserie Operation & Care Manual GAS Connections ClearancesPhysical Condition Transportation Damage and Claims Voltage Purchased From
Related manuals
Manual 2 pages 35.95 Kb

AR-6G specifications

The Alto-Shaam AR-6G is a state-of-the-art combi oven that exemplifies innovation in commercial kitchen technology. Designed for versatility and efficiency, the AR-6G is an essential asset for any foodservice operation looking to enhance its cooking capabilities.

One of the standout features of the Alto-Shaam AR-6G is its advanced cooking modes, including convection, steam, and combination cooking. This enables chefs to execute a variety of culinary techniques effortlessly. The ability to switch between dry heat and moist heat provides users with unparalleled control over cooking processes, ensuring that meats are succulent, vegetables are perfectly steamed, and baked goods achieve a golden finish.

The AR-6G is equipped with precise digital controls, allowing for easy customization of cooking temperatures and times. Users can set and monitor cooking parameters via a user-friendly interface that features programmable settings. This functionality helps streamline operations and reduces the chances of human error, making it ideal for high-volume environments.

Another significant aspect of the Alto-Shaam AR-6G is its efficiency. The oven is designed with energy-saving technologies that help reduce operational costs. Its efficient insulation maintains optimal temperatures while minimizing energy consumption. The self-cleaning feature also saves time and effort for kitchen staff by automating the cleaning process, ensuring that the oven remains in excellent condition with minimal downtime.

The AR-6G boasts a spacious cooking chamber capable of accommodating six full-size hotel pans, providing ample room for large batches of food. This is particularly beneficial for restaurants and catering businesses that require consistency and quality across multiple dishes.

Moreover, the Alto-Shaam AR-6G is designed with durability in mind. Constructed from high-quality materials, it can withstand the rigors of a busy kitchen environment. The oven’s sleek stainless-steel finish not only adds to its aesthetic appeal but also makes it easy to clean and maintain.

In summary, the Alto-Shaam AR-6G is a versatile and efficient combi oven that integrates advanced technology with user-friendly features. Its multiple cooking modes, precise controls, energy efficiency, and durable construction make it a valuable tool for any foodservice establishment aiming to deliver high-quality dishes consistently. Whether for baking, roasting, or steaming, the AR-6G is poised to meet the demands of modern culinary professionals.