Mitsubishi Electronics 882.00207.00 Follow all Safety Codes, Wear Safety Glasses and Work Gloves

Page 10

1-2 Warnings and Precautions

Our equipment is designed to provide safe and reliable operation when installed and operated within design specifications, following national and local safety codes. This may include, but is not limited to OSHA, NEC, CSA, SPI, and any other local, national and international regulations.

To avoid possible personal injury or equipment damage when installing, operating, or maintaining this equipment, use good judgment and follow these safe practices:

;Read and follow these operation and installation instructions when installing, operating, and maintaining this equipment. If these instructions become damaged or unreadable, additional copies are available from the manufacturer.

;Follow all SAFETY CODES.

;Keep fingers away from slide gates, augers, clean-outs, and calibration hatches. Automatic operation may start unexpectedly, A PINCH HAZARD CAPABLE OF

CAUSING BODILY INJURY EXISTS ANY TIME THE POWER IS ON.

;Wear SAFETY GLASSES and WORK GLOVES.

;Work only with approved tools and devices.

;Disconnect and/or lock out power and compressed air before servicing or maintaining the equipment.

;Use care when LOADING, UNLOADING, RIGGING, or MOVING this equipment.

;Operate this equipment within design specifications.

;OPEN, TAG, and LOCK ALL DISCONNECTS before working on equipment. You should remove the fuses and carry them with you.

;NEVER PUT FINGERS OR TOOLS IN AN AUGER OR SLIDE GATE AREA.

;Make sure the equipment and components are properly GROUNDED before you switch on power.

;Do not restore power until you remove all tools, test equipment, etc., and the equipment and related components are fully reassembled.

;Only PROPERLY TRAINED personnel familiar with the information in this manual should work on this equipment.

We have long recognized the importance of safety and have designed and manufactured our equipment with operator safety as a prime consideration. We expect you, as a user, to abide by the foregoing recommendations in order to make operator safety a reality.

Bulletin Number

Chapter 1: Safety

9 of 102

Image 10
Contents Gravimetric Slide Gate Batch Blender Mitsubishi Controller Parts and Service Department If the Shipment is Not Complete Unpacking and InspectionEvent of Shipping Damage If the Shipment is Not CorrectReturns Warranty ReturnsCredit Returns Table of Contents Maintenance Customer Responsibilities Technical Specifications How to Use This Manual Safety Symbols Used in this ManualSafety Tags and Warning Labels Description Follow all Safety Codes Wear Safety Glasses and Work GlovesGeneral Responsibility ResponsibilityOperator Responsibility Remember Maintenance Responsibility Reporting a Safety DefectModels Covered in This Manual AccessoriesCustomer Service General DescriptionEquipment Specifications Mechanical Features Typical Features and ComponentsController Features System Component Description Supply HoppersSlide Gates Typical Slide Gate Assembly Weigh HopperTypical Weigh Hopper Assembly Mix Chamber Operator Control Panel DisplayFunction Typical Operator Screens Typical Setup Screens Bulletin Number Functional Description Low Level Sensors Optional ComponentsPneumatic Slide Gate below Mixer Mezzanine and Floor StandsAdditive Feeder Hopper Regrind Auger Metering R.A.M. HopperTake-off Compartments Safety Device Lock-Outs Safety FeaturesSafety Circuit Standards Fail Safe OperationElectrical Disconnect Plug Twist Cap Plug Connected to Each Feeder Auger MotorElectric Safety Interlock Switch Electrical Safety Interlock Switch Located on mixer doorMechanical Installation Uncrating the EquipmentSite Requirements Mounting ConfigurationsMachine Mount Mezzanine Mount Typical Mezzanine Mounted Batch BlenderFloor Mount Central Blender Typical Floor Mount Central Blender LayoutElectrical Connections Pneumatic ConnectionsMechanical Set-up Initial Set-upStroke Limiters for Metering Gates Weigh Hopper Installation Weigh Hopper Final ConnectionsDisplay Main Recipe Screen Controller Set-upBlender Controller Menu Structure Recipe Page StartBlender Calibration Display Calibration Menu Screen Alarm Setup Feeder Calibration Auger BlendersNetwork Setup Setting Date and TimeAdditional Setup Parameters Initial Startup General Operation Quick Start ProcedureStart-up New RecipesOperation Procedures Existing RecipesOperator Displays Typical Recipe Entry Operator ScreenTypical Inventory Display Operator Screen Recipe Entry FormatsRecipe Format Menu Quickset Mode Most common in injection molding Example Calculations of a 5-component blend in Quickset mode Recipe Setup Percentage Mode Most common in extrusion and blow moldingSwitching Modes Current Recipe MenuTypical Batch Sizes Blender Batch Size lbs Inventory ShutdownMixer and Dump Setup Weigh Hopper Dump Delay Time Re-Mix TimerWeigh Hopper Dump Time Weigh Hopper Dump Cycle Alarm FlagsMixer Dump Time Calibration Error Typical PLC Battery Low Alarm Screen Feeder Clean Out Tree Diagram in -5 of this manual Recipe BookSave Running Recipe to the Book Display Recipe ContentsLoad a Saved Recipe from the Book Erase Recipe or Entire Book Color ChangesShut-down Typical Inventory Shutdown Operator ScreenPreventative Maintenance Schedule Sample Preventative Maintenance ScheduleElectrical Preventative MaintenanceCorrective Maintenance Internal Components of the Control PanelInput Signals to Programmable Controller Output Signals from Programmable ControllerTroubleshooting IntroductionProblem Corrective action Problem Corrective action Warranty will be voided Service Department Warranty Restrictions WarrantyWarranty Specifications Warranty LiabilitiesEquipment Specifications Technical SpecificationsCustomer Responsibilities Annex B Information Drawings and Diagrams Final AssemblyMixer Sub-Assembly Typical Mixer Assembly Parts List Hopper Sub-assembly Typical Hopper Assembly Parts ListHopper R.A.M. Regrind Auger Metering Sub-Assembly Optional Typical R.A.M. Hopper Assembly Parts ListHopper Additive Feeder Sub-Assembly Optional Typical Additive Feeder Hopper Assembly Parts ListWeigh Hopper Sub-assembly Typical Weigh Hopper Assembly Parts ListSlide Gate Sub-assembly Typical Slidegate Assembly Parts ListKnife Gate Sub-assembly HD Optional Typical Knife Gate below mixer Assembly Parts ListKnife Gate Sub-assembly RD Optional Typical Knife Gate floor stand Assembly Parts ListTypical Mitsubishi Controller Main Parts List Control Panel LayoutBlender Spare Parts Listing Spare Parts KitsPasswords Addendum Service Supervisor InformationProgrammable Settings Advanced Weight Options Screen Factory Setup MenuMetering Test Screen Feed Algorithm Options Screen Feed Calibration Options ScreenFeeder Setup Mechanical Options ScreenCustomer Setup Menu UnitsTypical Alarm Flags & Feeder Setup Screen Alarm LogFactory Default Setup Parameters Recipe FormatLoadcell Calex Module Dipswitch Settings Mitsubishi Communications Manual General Blender InfoBlender Alarms Inventory Info Recipe Info this is Where YOU Right the NEW Recipe to Recipe Book Manipulation Alarm Number Explanation Fixed Decimal ExplanationUntil the Hopper Feeds Material Into the NEW Batch Parts Department Service Department Sales DepartmentTechnical Assistance Contract Department
Related manuals
Manual 103 pages 37.01 Kb

882.00207.00 specifications

Mitsubishi Electronics has always been at the forefront of innovation in the field of electronics, and one of its significant products is the Mitsubishi Electronics 882.00207.00. This device is designed for enhanced performance and reliability, providing a range of features that cater to both industrial and consumer needs.

One of the main features of the Mitsubishi 882.00207.00 is its robust design, which ensures durability in demanding environments. The device is built to withstand harsh conditions, making it ideal for industrial applications where reliability is critical. Its rugged construction means that it can operate efficiently in extreme temperatures, humidity, and other challenging conditions.

In terms of technology, the Mitsubishi 882.00207.00 incorporates advanced electronic components that enhance its functionality. This includes state-of-the-art processing capabilities that allow for quick data processing and seamless operation. The device’s integration of cutting-edge technology ensures that it meets the performance demands of modern applications while providing energy efficiency.

Another notable characteristic is its user-friendly interface. The device is designed with ease of use in mind, allowing operators to interact with it effortlessly. This ensures that even those with minimal technical expertise can operate the device effectively. The clear display and intuitive controls make it accessible for a wide range of users, facilitating smoother operations in various settings.

The Mitsubishi 882.00207.00 is also equipped with multiple connectivity options. This enables it to integrate seamlessly with other devices and systems, facilitating enhanced communication and data transfer. Whether it’s connecting to existing networks or interfacing with new technologies, the device’s versatility ensures it can adapt to evolving technological landscapes.

Additionally, the device is backed by Mitsubishi's commitment to quality and customer support. Users can expect reliable service and assistance, ensuring that they can maximize the potential of their investment.

In conclusion, the Mitsubishi Electronics 882.00207.00 stands out in the electronics market for its durable construction, advanced technology, user-friendly design, and versatile connectivity options. This makes it an invaluable tool for both industrial applications and everyday consumer use, embodying the innovative spirit that Mitsubishi Electronics is known for.