Mitsubishi Electronics 882.00207.00 specifications Mixer and Dump Setup

Page 55

To enable this feature, simply enter a desired shutdown weight value (from 1 to 999999999) into the Inventory Shutdown display line of the Recipe Format screen, under the Setup menu.

This feature can be configured while the blender is making a batch. If the Inventory Shutdown is changed, then you will need to touch “Accept New Recipe” on the Recipe screen before the change can take place. This allows stored recipes with different Inventory Shutdown settings to easily be loaded without the operator having to reconfigure the blender every time they want to load a stored recipe.

To disable this feature, simply enter a zero (0) value.

Batch Ready Mode

This enables the blender to have a batch already made in the weigh hopper while the mixer is full. Enabling this feature dramatically increases the maximum achievable blender rate.

Auto Start Feature

By enabling this feature, the blender accurately finishes a batch that was interrupted by loss of blender power. This option starts the blender if it was running prior to power loss. It does not turn on the blender if it was previously stopped prior to power loss.

Mixer and Dump Setup

Mixer Options

Press the “Timed/Continuous Mixing” key (In the top right hand corner) when in “Mixer and Dump Setup” screen to set the following options:

Timed Mixing Option

This mode of operation turns the mixer on only during dumping and during the re-mix time set into the control to jog the mixer during high level mixer operation.

Continuous Mixing Option

This mode of operation turns the mixer on after initial startup and will continue to run continuously, unless the remix time is set to jog the mixer during high level mixer operation. This option is used for sticky materials that tend to bridge and block off the mixer discharge to the processing machine.

Mix Timer

The mix timer is the amount of time that the mix motor will mix the material after it has entered the mixing section of the Slide Gate/Auger blender. The timer has a range of 1 to 999 seconds.

To set the value of the mix timer, the user must gain access to the Setup Menu. After entering the Setup menu, the user must select “Mixer and Dump Setup.”

Figure 40: Typical Mixer and Dump Setup Operator Screen

Go Back to Setup

Directory

Bulletin Number

Chapter 4: Operation

54 of 102

Image 55
Contents Gravimetric Slide Gate Batch Blender Mitsubishi Controller Parts and Service Department If the Shipment is Not Correct Unpacking and InspectionEvent of Shipping Damage If the Shipment is Not CompleteReturns Warranty ReturnsCredit Returns Table of Contents Maintenance Customer Responsibilities Technical Specifications Safety Symbols Used in this Manual How to Use This ManualSafety Tags and Warning Labels Description Wear Safety Glasses and Work Gloves Follow all Safety CodesGeneral Responsibility ResponsibilityOperator Responsibility Remember Reporting a Safety Defect Maintenance ResponsibilityGeneral Description AccessoriesCustomer Service Models Covered in This ManualEquipment Specifications Mechanical Features Typical Features and ComponentsController Features Supply Hoppers System Component DescriptionSlide Gates Weigh Hopper Typical Slide Gate AssemblyTypical Weigh Hopper Assembly Operator Control Panel Display Mix ChamberFunction Typical Operator Screens Typical Setup Screens Bulletin Number Functional Description Mezzanine and Floor Stands Optional ComponentsPneumatic Slide Gate below Mixer Low Level SensorsAdditive Feeder Hopper Regrind Auger Metering R.A.M. HopperTake-off Compartments Fail Safe Operation Safety FeaturesSafety Circuit Standards Safety Device Lock-OutsTwist Cap Plug Connected to Each Feeder Auger Motor Electrical Disconnect PlugElectrical Safety Interlock Switch Located on mixer door Electric Safety Interlock SwitchUncrating the Equipment Mechanical InstallationSite Requirements Mounting ConfigurationsMachine Mount Typical Mezzanine Mounted Batch Blender Mezzanine MountTypical Floor Mount Central Blender Layout Floor Mount Central BlenderPneumatic Connections Electrical ConnectionsMechanical Set-up Initial Set-upStroke Limiters for Metering Gates Weigh Hopper Final Connections Weigh Hopper InstallationController Set-up Display Main Recipe ScreenRecipe Page Start Blender Controller Menu StructureBlender Calibration Display Calibration Menu Screen Feeder Calibration Auger Blenders Alarm SetupSetting Date and Time Network SetupAdditional Setup Parameters Initial Startup New Recipes Quick Start ProcedureStart-up General OperationExisting Recipes Operation ProceduresTypical Recipe Entry Operator Screen Operator DisplaysRecipe Entry Formats Typical Inventory Display Operator ScreenRecipe Format Menu Quickset Mode Most common in injection molding Example Calculations of a 5-component blend in Quickset mode Current Recipe Menu Percentage Mode Most common in extrusion and blow moldingSwitching Modes Recipe SetupInventory Shutdown Typical Batch Sizes Blender Batch Size lbsMixer and Dump Setup Weigh Hopper Dump Delay Time Re-Mix TimerWeigh Hopper Dump Time Weigh Hopper Dump Cycle Alarm FlagsMixer Dump Time Calibration Error Typical PLC Battery Low Alarm Screen Feeder Clean Out Recipe Book Tree Diagram in -5 of this manualSave Running Recipe to the Book Display Recipe ContentsLoad a Saved Recipe from the Book Color Changes Erase Recipe or Entire BookTypical Inventory Shutdown Operator Screen Shut-downSample Preventative Maintenance Schedule Preventative Maintenance ScheduleInternal Components of the Control Panel Preventative MaintenanceCorrective Maintenance ElectricalOutput Signals from Programmable Controller Input Signals to Programmable ControllerIntroduction TroubleshootingProblem Corrective action Problem Corrective action Warranty will be voided Service Department Warranty Liabilities WarrantyWarranty Specifications Warranty RestrictionsEquipment Specifications Technical SpecificationsCustomer Responsibilities Annex B Information Final Assembly Drawings and DiagramsMixer Sub-Assembly Typical Mixer Assembly Parts List Typical Hopper Assembly Parts List Hopper Sub-assemblyTypical R.A.M. Hopper Assembly Parts List Hopper R.A.M. Regrind Auger Metering Sub-Assembly OptionalTypical Additive Feeder Hopper Assembly Parts List Hopper Additive Feeder Sub-Assembly OptionalTypical Weigh Hopper Assembly Parts List Weigh Hopper Sub-assemblyTypical Slidegate Assembly Parts List Slide Gate Sub-assemblyTypical Knife Gate below mixer Assembly Parts List Knife Gate Sub-assembly HD OptionalTypical Knife Gate floor stand Assembly Parts List Knife Gate Sub-assembly RD OptionalControl Panel Layout Typical Mitsubishi Controller Main Parts ListSpare Parts Kits Blender Spare Parts ListingPasswords Addendum Service Supervisor InformationProgrammable Settings Advanced Weight Options Screen Factory Setup MenuMetering Test Screen Feed Calibration Options Screen Feed Algorithm Options ScreenMechanical Options Screen Feeder SetupUnits Customer Setup MenuAlarm Log Typical Alarm Flags & Feeder Setup ScreenRecipe Format Factory Default Setup ParametersLoadcell Calex Module Dipswitch Settings General Blender Info Mitsubishi Communications ManualBlender Alarms Inventory Info Recipe Info this is Where YOU Right the NEW Recipe to Recipe Book Manipulation Fixed Decimal Explanation Alarm Number ExplanationUntil the Hopper Feeds Material Into the NEW Batch Contract Department Service Department Sales DepartmentTechnical Assistance Parts Department
Related manuals
Manual 103 pages 37.01 Kb

882.00207.00 specifications

Mitsubishi Electronics has always been at the forefront of innovation in the field of electronics, and one of its significant products is the Mitsubishi Electronics 882.00207.00. This device is designed for enhanced performance and reliability, providing a range of features that cater to both industrial and consumer needs.

One of the main features of the Mitsubishi 882.00207.00 is its robust design, which ensures durability in demanding environments. The device is built to withstand harsh conditions, making it ideal for industrial applications where reliability is critical. Its rugged construction means that it can operate efficiently in extreme temperatures, humidity, and other challenging conditions.

In terms of technology, the Mitsubishi 882.00207.00 incorporates advanced electronic components that enhance its functionality. This includes state-of-the-art processing capabilities that allow for quick data processing and seamless operation. The device’s integration of cutting-edge technology ensures that it meets the performance demands of modern applications while providing energy efficiency.

Another notable characteristic is its user-friendly interface. The device is designed with ease of use in mind, allowing operators to interact with it effortlessly. This ensures that even those with minimal technical expertise can operate the device effectively. The clear display and intuitive controls make it accessible for a wide range of users, facilitating smoother operations in various settings.

The Mitsubishi 882.00207.00 is also equipped with multiple connectivity options. This enables it to integrate seamlessly with other devices and systems, facilitating enhanced communication and data transfer. Whether it’s connecting to existing networks or interfacing with new technologies, the device’s versatility ensures it can adapt to evolving technological landscapes.

Additionally, the device is backed by Mitsubishi's commitment to quality and customer support. Users can expect reliable service and assistance, ensuring that they can maximize the potential of their investment.

In conclusion, the Mitsubishi Electronics 882.00207.00 stands out in the electronics market for its durable construction, advanced technology, user-friendly design, and versatile connectivity options. This makes it an invaluable tool for both industrial applications and everyday consumer use, embodying the innovative spirit that Mitsubishi Electronics is known for.