Mitsubishi Electronics 882.00207.00 specifications Electrical Connections, Pneumatic Connections

Page 35

3-3 Electrical Connections

The standard Slide Gate/Auger blending system is designed to operate on 120/1/60 supply voltage (220/1/50 CE models are also available). The current requirements vary with the blender’s size and throughput rating. For exact current requirements, check the blender serial number tag, located on the rear plate of the mixer section.

If a step down transformer was provided, it should never be used to power anything other than the blender. Loading equipment, etc. must be powered by another power source. As well as possibly overloading the transformer, the additional equipment may induce power line noise that may affect the operation of the blending system.

The transformer will be mounted and wired by the customer or your installer. If company or local codes require fusing or disconnects, these items must be supplied, wired, and mounted by the customer.

Note: Each blending system MUST be connected to a separate source of power. Do not connect other electrical equipment, especially self- contained hopper loaders, on the same line as the blending system.

Ensure that the power entrance location on the blender panel remains unchanged. Make sure that the proper size wire and proper wire routing techniques are used when installing the supply wiring to the control panel. Care must be taken to ensure that the supply wiring does not interfere with the low voltage DC wiring.

The blender is equipped with a plug that functions as the disconnect device (See Figure 11 on Page 27 for an example). The mating receptacle must be installed no higher than 5’ feet

(1.6 m) above the floor. Make sure your installation conforms to your regional electrical standards.

3-4 Pneumatic Connections

The Slide Gate/Auger blending system uses plant-supplied compressed air to operate the metering and dump valves on the blender.

CLEAN AND DRY air must be supplied to the blender. The air supply should be filtered through a 5 micron air filter with a water separator. Oil should not be used unless air dryers are installed on the compressed air supply. In this situation, an oiler may be required on the blender to keep the air cylinder seals lubricated.

Note: As this blender uses air for blender metering functions, it is very important to supply clean, dry air to the blender. Dirty or oily air can affect blender accuracy; result in poor performance, and cause injury. Provide a 5-micron air filter on the air supply to the blender, and be sure excess oil is removed. Also, use a dedicated line to ensure proper air supply.

Figure 23: Customer-Supplied Pneumatic Components

Bulletin Number

Chapter 3: Installation

34 of 102

Image 35
Contents Gravimetric Slide Gate Batch Blender Mitsubishi Controller Parts and Service Department If the Shipment is Not Correct Unpacking and InspectionEvent of Shipping Damage If the Shipment is Not CompleteCredit Returns Warranty ReturnsReturns Table of Contents Maintenance Customer Responsibilities Technical Specifications Safety Symbols Used in this Manual How to Use This ManualSafety Tags and Warning Labels Description Wear Safety Glasses and Work Gloves Follow all Safety CodesOperator Responsibility ResponsibilityGeneral Responsibility Remember Reporting a Safety Defect Maintenance ResponsibilityGeneral Description AccessoriesCustomer Service Models Covered in This ManualEquipment Specifications Controller Features Typical Features and ComponentsMechanical Features Supply Hoppers System Component DescriptionSlide Gates Weigh Hopper Typical Slide Gate AssemblyTypical Weigh Hopper Assembly Operator Control Panel Display Mix ChamberFunction Typical Operator Screens Typical Setup Screens Bulletin Number Functional Description Mezzanine and Floor Stands Optional ComponentsPneumatic Slide Gate below Mixer Low Level SensorsTake-off Compartments Regrind Auger Metering R.A.M. HopperAdditive Feeder Hopper Fail Safe Operation Safety FeaturesSafety Circuit Standards Safety Device Lock-OutsTwist Cap Plug Connected to Each Feeder Auger Motor Electrical Disconnect PlugElectrical Safety Interlock Switch Located on mixer door Electric Safety Interlock SwitchUncrating the Equipment Mechanical InstallationMachine Mount Mounting ConfigurationsSite Requirements Typical Mezzanine Mounted Batch Blender Mezzanine MountTypical Floor Mount Central Blender Layout Floor Mount Central BlenderPneumatic Connections Electrical ConnectionsStroke Limiters for Metering Gates Initial Set-upMechanical Set-up Weigh Hopper Final Connections Weigh Hopper InstallationController Set-up Display Main Recipe ScreenRecipe Page Start Blender Controller Menu StructureBlender Calibration Display Calibration Menu Screen Feeder Calibration Auger Blenders Alarm SetupSetting Date and Time Network SetupAdditional Setup Parameters Initial Startup New Recipes Quick Start ProcedureStart-up General OperationExisting Recipes Operation ProceduresTypical Recipe Entry Operator Screen Operator DisplaysRecipe Entry Formats Typical Inventory Display Operator ScreenRecipe Format Menu Quickset Mode Most common in injection molding Example Calculations of a 5-component blend in Quickset mode Current Recipe Menu Percentage Mode Most common in extrusion and blow moldingSwitching Modes Recipe SetupInventory Shutdown Typical Batch Sizes Blender Batch Size lbsMixer and Dump Setup Weigh Hopper Dump Time Re-Mix TimerWeigh Hopper Dump Delay Time Mixer Dump Time Alarm FlagsWeigh Hopper Dump Cycle Calibration Error Typical PLC Battery Low Alarm Screen Feeder Clean Out Recipe Book Tree Diagram in -5 of this manualLoad a Saved Recipe from the Book Display Recipe ContentsSave Running Recipe to the Book Color Changes Erase Recipe or Entire BookTypical Inventory Shutdown Operator Screen Shut-downSample Preventative Maintenance Schedule Preventative Maintenance ScheduleInternal Components of the Control Panel Preventative MaintenanceCorrective Maintenance ElectricalOutput Signals from Programmable Controller Input Signals to Programmable ControllerIntroduction TroubleshootingProblem Corrective action Problem Corrective action Warranty will be voided Service Department Warranty Liabilities WarrantyWarranty Specifications Warranty RestrictionsCustomer Responsibilities Technical SpecificationsEquipment Specifications Annex B Information Final Assembly Drawings and DiagramsMixer Sub-Assembly Typical Mixer Assembly Parts List Typical Hopper Assembly Parts List Hopper Sub-assemblyTypical R.A.M. Hopper Assembly Parts List Hopper R.A.M. Regrind Auger Metering Sub-Assembly OptionalTypical Additive Feeder Hopper Assembly Parts List Hopper Additive Feeder Sub-Assembly OptionalTypical Weigh Hopper Assembly Parts List Weigh Hopper Sub-assemblyTypical Slidegate Assembly Parts List Slide Gate Sub-assemblyTypical Knife Gate below mixer Assembly Parts List Knife Gate Sub-assembly HD OptionalTypical Knife Gate floor stand Assembly Parts List Knife Gate Sub-assembly RD OptionalControl Panel Layout Typical Mitsubishi Controller Main Parts ListSpare Parts Kits Blender Spare Parts ListingProgrammable Settings Addendum Service Supervisor InformationPasswords Metering Test Screen Factory Setup MenuAdvanced Weight Options Screen Feed Calibration Options Screen Feed Algorithm Options ScreenMechanical Options Screen Feeder SetupUnits Customer Setup MenuAlarm Log Typical Alarm Flags & Feeder Setup ScreenRecipe Format Factory Default Setup ParametersLoadcell Calex Module Dipswitch Settings General Blender Info Mitsubishi Communications ManualBlender Alarms Inventory Info Recipe Info this is Where YOU Right the NEW Recipe to Recipe Book Manipulation Fixed Decimal Explanation Alarm Number ExplanationUntil the Hopper Feeds Material Into the NEW Batch Contract Department Service Department Sales DepartmentTechnical Assistance Parts Department
Related manuals
Manual 103 pages 37.01 Kb

882.00207.00 specifications

Mitsubishi Electronics has always been at the forefront of innovation in the field of electronics, and one of its significant products is the Mitsubishi Electronics 882.00207.00. This device is designed for enhanced performance and reliability, providing a range of features that cater to both industrial and consumer needs.

One of the main features of the Mitsubishi 882.00207.00 is its robust design, which ensures durability in demanding environments. The device is built to withstand harsh conditions, making it ideal for industrial applications where reliability is critical. Its rugged construction means that it can operate efficiently in extreme temperatures, humidity, and other challenging conditions.

In terms of technology, the Mitsubishi 882.00207.00 incorporates advanced electronic components that enhance its functionality. This includes state-of-the-art processing capabilities that allow for quick data processing and seamless operation. The device’s integration of cutting-edge technology ensures that it meets the performance demands of modern applications while providing energy efficiency.

Another notable characteristic is its user-friendly interface. The device is designed with ease of use in mind, allowing operators to interact with it effortlessly. This ensures that even those with minimal technical expertise can operate the device effectively. The clear display and intuitive controls make it accessible for a wide range of users, facilitating smoother operations in various settings.

The Mitsubishi 882.00207.00 is also equipped with multiple connectivity options. This enables it to integrate seamlessly with other devices and systems, facilitating enhanced communication and data transfer. Whether it’s connecting to existing networks or interfacing with new technologies, the device’s versatility ensures it can adapt to evolving technological landscapes.

Additionally, the device is backed by Mitsubishi's commitment to quality and customer support. Users can expect reliable service and assistance, ensuring that they can maximize the potential of their investment.

In conclusion, the Mitsubishi Electronics 882.00207.00 stands out in the electronics market for its durable construction, advanced technology, user-friendly design, and versatile connectivity options. This makes it an invaluable tool for both industrial applications and everyday consumer use, embodying the innovative spirit that Mitsubishi Electronics is known for.