| ITEMS AFFECTED BY ERROR |
| |||
|
|
|
|
|
|
|
MESSAGE |
| BEATER | BEATER | REFRIG 1 |
| REFRIG 2 |
DISPLAYED | ERROR | MOTOR 1 | MOTOR 2 |
| ||
Motor 1 | Low Current, < 109, | OFF |
| OFF |
|
|
| Sensed on Motor One |
|
|
|
|
|
|
|
|
|
|
|
|
Motor 2 | Low Current, < 109, |
| OFF |
|
| OFF |
| Sensed on Motor Two |
|
|
|
|
|
|
|
|
|
|
|
|
Motor 1 | High Current > 255, | OFF |
| OFF |
|
|
| Sensed on Motor One |
|
|
|
|
|
|
|
|
|
|
|
|
Motor 2 | High Current > 255, |
| OFF |
|
| OFF |
| Sensed on Motor Two |
|
|
|
|
|
|
|
|
|
|
|
|
REFRIG | **Maximum Run Time on Compressor | OFF | OFF | OFF |
| OFF |
|
|
|
|
|
|
|
SYRUP 1 | Syrup Out Side One |
|
| OFF |
|
|
|
|
|
|
|
|
|
SYRUP 2 | Syrup Out Side Two |
|
|
|
| OFF |
|
|
|
|
|
|
|
CO2 OUT | CO2 Out |
|
| OFF |
| OFF |
|
|
|
|
|
|
|
H2O | H2O Out |
|
| *OFF |
| *OFF |
|
|
|
|
|
|
|
SENSOR 1 | Temp Sensor Inlet One | OFF | OFF | OFF |
| OFF |
|
|
|
|
|
|
|
SENSOR 2 | Temp Sensor Inlet Two | OFF | OFF | OFF |
| OFF |
|
|
|
|
|
|
|
SENSOR 3 | Temp Sensor Outlet | OFF | OFF | OFF |
| OFF |
|
|
|
|
|
|
|
*The refrigeration system and carbonator shall continue to operate for 1.5 minutes after a water pressure loss has been detected. If water pressure loss continues beyond 1.5 minutes, the refrigeration system and carbonator will stop.
**25 minutes on Standard System, 30 minutes on Remote System.
TABLE 9 DISPLAYED ERROR CONDITIONS
3.Press “CANCEL DEFROST” (ADVANCE) switch. The motor manufacturer’s name will start blinking.
4.Press the “CANCEL DEFROST” (ADVANCE) switch again, which will change to another blinking manufac- turer’s name.
5.Keep pressing and releasing the “CANCEL DEFROST” (ADVANCE) switch until the applicable blinking manufacturer’s name appears on the message display. This indicates manufacturer’s name of the No. 1 freeze cylinder beater motor (new Unit installation) or the new installed replacement motor.
6.After the applicable beater motor manufacturer’s name has been selected, press “DEFROST” (SELECT) switch which will match the beater motor to the Unit electronics. The motor manufacturer’s name will no longer be blinking.
7.Press “DEFROST” (SELECT) switch to return to “MOT_MFG1”.
8.Press “CANCEL DEFROST” (ADVANCE) switch to go from “MOT_MFG1” to “MOT_MFG2” (represents No. 2 freeze cylinder beater motor) which will appear on the message display.
9.Repeat steps 2 through 6 to program in the correct beater motor manufacturer’s name for No. 2 freeze cylinder.
PROGRAMMING PROPER REFRIGERANT TYPE INTO UNIT ELECTRONICS
The Dispenser electronics must be programmed for the proper refrigeration pulse rate according to the type of refrigerant gas that has been installed in the refrigeration system. Note Dispenser serial plate for the type of re- frigerant gas that has been installed, then proceed as follows to program the Dispenser.