Cornelius R-404A REFRIGERANT Adjusting ‘‘VIS SET’’ Product Viscosity of Dispensed Product

Page 42

PROGRAMMING ‘‘SLEEP’’ (SLEEP TIME) INTO UNIT

‘‘SLEEP’’ (SLEEP TIME) may be programmed into Unit to occur any time of the day after the Unit automatic defrost cycle has occurred. Unit will shut down (go into sleep time) and will not wake up (return to normal opera- tion) until programmed ‘‘WAKE UP’’ (WAKE UP TIME) has occurred. Program ‘‘SLEEP’’ (SLEEP TIME) into Unit as instructed in the INSTALLATION section.

PROGRAMMING ‘‘WAKE UP’’ (WAKE UP) TIME INTO UNIT

‘‘WAKE UP’’ (WAKE UP TIME) may be programmed into Unit to occur any time of the day to wake Unit up (re- turn to normal operation) after ‘‘sleep time’’ has occurred. Program ‘‘WAKE UP’’ into Unit as instructed in the INSTALLATION section.

PROGRAMMING POINT OF SALE MESSAGE DISPLAY

Three point of sale display messages are available to choose from and may be programmed into Unit by placing No.1 and No. 2 switches on DIP SWITCH assembly on master circuit board in appropriate positions. Program point of sale display messages into Unit as instructed in the INSTALLATION section.

ADJUSTING ‘‘VIS SET’’ (PRODUCT VISCOSITY) OF DISPENSED PRODUCT

Adjusting ‘‘VIS SET’’ (PRODUCT VISCOSITY) determines what product consistency of the dispensed product will be present in each freeze cylinder. Adjust ‘‘VIS SET’’ (PRODUCT VISCOSITY) of the dispensed product as instructed in the INSTALLATION section.

“VIS READ” (ACTUAL VISCOSITY READOUT) OF PRODUCT IN FREEZE CYLINDERS

“VIS READ” (actual viscosity readout) may be brought up on the message display to actually read the viscosity (product consistency) of product in the freeze cylinders while the Unit is in operation as instructed in the INSTALLATION section.

DISPLAYED EVAPORATOR REFRIGERATION COILS INLETS AND COMMON OUTLET SENSORS TEMPERATURES

Evaporator refrigeration coils inlet and common outlet temperature readings in degrees Fahrenheit may be dis- played on message display as instructed in the INSTALLATION section.

‘‘VOLTAGE’’ (DISPLAYED VOLTAGE READOUT)

Displayed voltage readout may be displayed on message display as instructed in the INSTALLATION section.

PROGRAMMING COMPONENTS ‘‘DIAGNOSE’’ (DIAGNOSTIC MODE) INTO UNIT

‘‘DIAGNOSE’’ (DIAGNOSTIC MODE) may be programmed into the Unit to check certain components for operation. Program ‘‘DIAGNOSE’’ into the Unit and check components for proper operation as instructed in the INSTALLATION section.

DISPLAYING ‘‘TOTALS’’ (DISPLAYED CYCLES AND HOURS TOTALS) ONTO MESSAGE DISPLAY

‘‘TOTALS’’ (DISPLAYED CYCLES AND HOURS TOTALS) may be displayed on the message display as instructed in the INSTALLATION section.

35

312028000

Image 42
Contents To the Installer Table of Contents Table of Contents cont’d Water Strainer Screen and Double Liquid Check Valve Programming Main Menu Selections Onto Message DisplayVIS Read Actual Viscosity Readout of Product Preparing Unit for SHIPPING, STORING, or RelocatingTroubleshooting Control Panel Switches and Fault Product Carbonation AdjustmentDaily Cleaning of Unit Sanitizing Syrup Systems ‘‘ERROR 1’’ or ‘‘ERROR 2’’ Fault Message Goes on DuringDefrost Cycle does not Cancel After Pressing ‘‘CANCEL Freeze Cylinder Automatic Defrost Cycle does notList of Figures Table of Contents cont’d General Description Unit DescriptionTheory of Operation AccessoriesService Tools Generic Flavor TabsDefrost Systems Manual Defrost SystemAutomatic Defrost System ‘‘SLEEP’’ Sleep Time ‘‘WAKE UP’’ Wake UP TimeFlow Diagram This page Left Blank Intentionally Unpacking and Inspection Identification of LOOSE-SHIPPED PartsElectrical Power Requirements Selecting LocationHZ Unit Installing Drip Tray Supports Item 7 and Item Installing UnitInstalling Leveling Legs Installing Drip Tray Drain Hose KIT ItemInstalling Primary CO2 Regulator Assembly on CO2 Cylinder Connecting CO2 Source Line to Unit CO2 Inlet LineConnecting City Plain Water Source Line to Unit Connecting Electrical Power Circuit to the UnitElectrical BOX Adjusting Product Blender Tanks Secondary CO2 Turning on Electrical Power to UnitAdjusting Primary CO2 Regulator Adjusting Carbonator Secondary CO2 RegulatorHidden Security Switch Message Display Control Panel ASS’YFilling Freeze Cylinders with Product Checking Unit for SYRUP, CO2, or Plain Water LeaksAdjusting Beater Motor Current Either Side Placing Unit in Operating LocationSetting Clock Time of DAY Programming Main Menu Selection Onto Message DisplayProgramming ‘‘DEFROST’’ Automatic Settings Into Unit Menu SelectionsMain Menu Selections Switch Function DIP Switch FunctionsProgramming ‘‘SLEEP’’ Sleep Time Into Unit Programming ‘‘WAKE UP’’ Wake UP Time Into Unit Programming Point of Sale Message DisplayAdjusting VIS SET Product Viscosity of Dispensed Product Master and Relay Circuit Board ‘‘VOLTAGE’’ Displayed Voltage Readout 312028000 Brix Totals Menu Commands DescriptionSyrup Minutes Side Gallons = a X Syrup MinutesDisplayed Error Conditions Programming Proper Refrigerant Type Into Unit ElectronicsDisplayed Error Conditions Control Panel ASS’Y Switches and Displayed Messages Control Panel ASS’Y SwitchesControl Panel Assembly Display Messages ‘‘SECURITY SWITCH.’’Freeze Cylinders Manual or Automatic Defrost Systems Product Sample Valves ‘‘SLEEP’’ Sleep Time OperationFaceplate Relief Valves Product Shutoff ValvesDispensed Product Conditions Syrup Flow RegulatorsDispensing Valves ‘‘OVERRUN’’, AS Applied to Frozen Carbonated BeveragesOperating Characteristics Operating UnitReplenishing Syrup Supply Product Flavor Change Cleaning and SanitizingCleaning Condenser Coil Checking CO2 SupplyAdjustments Adjusting ‘‘VIS SET’’ Product Viscosity of Dispensed Product Cleaning CO2 GAS Check Valves TOP Panel Preparing Unit for SHIPPING, STORING, or RelocatingPeriodic Inspection Back PanelOpening Front Access Door Opening and Closing Front Access DoorFront Access Panel Closing Front Access DoorOperating Controls Unit Internal Components SELF-CLOSING Dispensing Valve 312028000 Adjusting Plain Water Pressure Regulator Adjusting Carbonated Water Flow RateFreeze Cylinder Cutaway View Servicing Beater Motor Drive SHAFT/SEAL Assembly Beaters and Scraper Blades Installation Adjusting CO2 Regulators Adjusting Brix WATER-TO-SYRUP ‘‘RATIO’’ of Dispensed Product Product Carbonation Adjustment Daily Cleaning of UnitSanitizing Syrup Systems To disconnect soft drink tank from Unit syrup system 312028000 Yearly or After Water System Disruption Servicing Carbonator Water Pump Water Strainer ScreenLiquid Check Valve Assembly Servicing Carbonator Water Pump Double Liquid Check ValveReplenishing Syrup Supply Service and Maintenance Section Replenishing CO2 SupplySyrup Flavor Change Water Strainer Screen and Double Liquid Check Valve Serviced Replacing Freeze Cylinder Beater Drive MotorAdjusting Carbonator Tank Liquid Level Ments in Small IncrementsCarbonator Liquid Level Control Switch Adjustment Refrigeration Flow Diagram Wiring Diagram This page Left Blank Intentionally Troubleshooting Control Panel Switches and Fault Messages ALL Fault Messages not a Control Panel SwitchesPoorly Illuminated Display ONE or More Fault Cannot be Deactivated‘‘H2O OUT’’ Fault Message ALL Fault Message not‘‘CO2 OUT’’ Fault Message Fault Message Goes onTroubleshooting Product Blender Tanks and Carbonator Troubleshooting Dispensed Product Excessively Frozen ProductConsistency Varies FREEZE-UPIllustrated Parts Breakdown Unit Part NumbersOvercounter FCB POST-MIX Dispenser FCB POST-MIX Dispenser FCB POST-MIX Dispenser cont’d Name Secondary CO2 Regulator Components Secondary CO2 Regulator ASS’Y CO2 Regulator Assembly Blender and Tubing Components Tubing Assembly Carb Water Tubing Assembly Water Solenoid to Blender Solenoid Valve Assembly Blender Components Control BOX and Display Panel Components Faceplate Assembly Dispensing Valve Assembly Carbonator Components Carbonator Tank and Linkage Assembly Pump and Motor ASS’Y Beater Motor Drive SHAFT/SEAL ASS’Y Warranty This page Left Blank Intentionally One Cornelius Place Anoka, Minnesota 612 800