Trouble | Probable Cause | Remedy |
CARBONATOR WATER PUMP A. | Binding, damaged, or dirty | A. Clean, repair, or replace balance |
WILL NOT SHUT OFF. | carbonated water tank balance | mechanism. |
| mechanism. |
|
|
|
|
ERRATIC CARBONATOR | A. Insufficient water supply |
WATER PUMP CYCLING. | pressure. ‘‘H2O OUT’’ fault |
| message goes on and off |
| intermittently and water pump |
| cycles on and off during |
| carbonator tank fill cycle. |
A.Increase water inlet supply line pressure. Water inlet supply line must have large enough I.D.
B. Water filter restricted. | B. Replace water filter. |
TROUBLESHOOTING DISPENSED PRODUCT
BRIX | A. Quick disconnect not secure |
‘‘RATIO’’ TOO LOW. | on soft drink tank. |
A.Secure tank quick disconnect.
| B. | Syrup flow regulator set too | B. | Adjust BRIX of dispensed product | |
|
| low. |
| as instructed. | |
| C. | Water flow regulator set too | C. | Water flow regulator must be set | |
|
| high. |
| at 1.3 ± | 0.05 oz/sec. |
| D. | Syrup flow regulators stuck. | D. | Clean syrup flow regulators. | |
| E. | Restriction in syrup line. | E. | Sanitize Unit as instructed. | |
| F. | Syrup Baume not in proper | F. | Change syrup supply as | |
|
| range. |
| instructed. | |
|
|
|
|
| |
BRIX | A. | Syrup flow regulators set too | A. | Adjust BRIX of dispensed product | |
‘‘RATIO’’ TOO HIGH. |
| high. |
| as instructed. | |
| B. | Water flow regulator set too | B. | Water flow regulator must be set | |
|
| low. |
| for 1.3 | ± 0.05 oz/sec. |
| C. | Water flow regulator stuck. | C. | Clean | regulator. |
| D. | Syrup Baume not in proper | D. | Change syrup supply as | |
|
| range. |
| instructed. | |
| E. | Restricted water filter. | E. | Replace water filter. | |
|
|
|
|
| |
IMPROPER PRODUCT | A. | Secondary CO2 regulators not | A. | Adjust secondary CO2 regulators | |
DISPENSED. |
| properly adjusted. |
| as instructed. | |
| B. | Dirty CO2 supply. CO2 must | B. | Replace CO2 supply as | |
|
| be clean and free of water, oil, |
| instructed. |
and dirt. Water will not absorb dirty CO2 gas in same way as clean gas. This can also cause
PRODUCT WILL NOT
DISPENSE OUT OF DISPENSING VALVE, IN ONLY SMALL AMOUNTS, OR ONLY LIQUID.
A.Dispensing valve has ice particles in it.
A.Open and close dispensing valve repeatedly. Defrost freeze cylinder as instructed. If necessary, check and adjust BRIX as instructed. Adjust viscosity of dispensed product as instructed.
| B. | Cylinder | B. | Refer to CYLINDER |
FREEZE CYLINDER DOES | A. | ‘‘AUTO BLEND 1’’ or ‘‘AUTO | A. | Press ‘‘AUTO BLEND 1’’ or |
NOT REFILL AT ALL TIMES |
| BLEND 2’’ switch not pressed. |
| ‘‘AUTO BLEND 2’’ switch. |
WHEN DISPENSING. |
|
|
|
|
B.Carbonator water pump not operating.
B.Check carbonator and restore to operation.