SERVICE AND MAINTENANCE

This section describes service and maintenance to be performed on the Unit.

WARNING: Disconnect electrical power to Unit to prevent personal injury before attempting any internal maintenance. Only qualified personnel should service internal components or electrical wiring.

PREPARING UNIT FOR SHIPPING, STORING, OR RELOCATING

CAUTION: Before shipping, storing, or relocating Unit, syrup systems must be sanitized and all sanitizing solution must be purged from syrup systems. All water must also be purged from plain and carbonated water systems. A freezing ambient environment will

cause residual sanitizing solution or water remaining inside Unit to freeze resulting in damage to internal components.

PERIODIC INSPECTION

1.Make sure CO2 cylinder valve is fully opened and primary CO2 cylinder regulator assembly 1800-psi gage indicator is not in shaded (‘‘change CO2 cylinder’’) portion of dial. If so, CO2 cylinder is almost empty and must be replaced.

2.Make sure soft drink tanks contain sufficient amount of syrup for Unit operation.

3.The FCB Dispenser refrigeration system is equipped with a condenser coil (see Figure 6) that is cooled by two condenser coil fans. Circulating air, required to cool the refrigeration system’s condenser coil, is drawn in through a grilled panel on the right-hand side and is exhausted out through the opposite side and back grilled panels. Restricting air circulation through the Unit will decrease its cooling efficiency. THE CON-

DENSER COIL MUST BE CLEANED PERIODICALLY AS INSTRUCTED IN THE SERVICE AND MAIN- TENANCE SECTION.

REMOVAL OF TOP PANEL, BACK PANEL, SIDE PANELS, AND FRONT ACCESS PANEL

(see Figure 5)

TOP PANEL

Remove two screws securing the top panel, then lift panel up off Unit.

BACK PANEL

Remove one screw securing back panel, then lift panel straight up to remove.

SIDE PANELS

Remove screw securing side panel, then lift panel straight up to remove.

37

312028000

 

Image 44
Contents To the Installer Table of Contents Table of Contents cont’d Programming Main Menu Selections Onto Message Display VIS Read Actual Viscosity Readout of ProductWater Strainer Screen and Double Liquid Check Valve Preparing Unit for SHIPPING, STORING, or RelocatingProduct Carbonation Adjustment Daily Cleaning of Unit Sanitizing Syrup SystemsTroubleshooting Control Panel Switches and Fault ‘‘ERROR 1’’ or ‘‘ERROR 2’’ Fault Message Goes on DuringList of Figures Defrost Cycle does not Cancel After Pressing ‘‘CANCELFreeze Cylinder Automatic Defrost Cycle does not Table of Contents cont’d General Description Unit DescriptionAccessories Service ToolsTheory of Operation Generic Flavor TabsAutomatic Defrost System Defrost SystemsManual Defrost System ‘‘SLEEP’’ Sleep Time ‘‘WAKE UP’’ Wake UP TimeFlow Diagram This page Left Blank Intentionally Unpacking and Inspection Identification of LOOSE-SHIPPED PartsHZ Unit Electrical Power RequirementsSelecting Location Installing Unit Installing Leveling LegsInstalling Drip Tray Supports Item 7 and Item Installing Drip Tray Drain Hose KIT ItemInstalling Primary CO2 Regulator Assembly on CO2 Cylinder Connecting CO2 Source Line to Unit CO2 Inlet LineElectrical BOX Connecting City Plain Water Source Line to UnitConnecting Electrical Power Circuit to the Unit Turning on Electrical Power to Unit Adjusting Primary CO2 RegulatorAdjusting Product Blender Tanks Secondary CO2 Adjusting Carbonator Secondary CO2 RegulatorHidden Security Switch Message Display Control Panel ASS’YFilling Freeze Cylinders with Product Checking Unit for SYRUP, CO2, or Plain Water LeaksAdjusting Beater Motor Current Either Side Placing Unit in Operating LocationSetting Clock Time of DAY Programming Main Menu Selection Onto Message DisplayMain Menu Selections Programming ‘‘DEFROST’’ Automatic Settings Into UnitMenu Selections Programming ‘‘SLEEP’’ Sleep Time Into Unit Switch FunctionDIP Switch Functions Programming ‘‘WAKE UP’’ Wake UP Time Into Unit Programming Point of Sale Message DisplayAdjusting VIS SET Product Viscosity of Dispensed Product Master and Relay Circuit Board ‘‘VOLTAGE’’ Displayed Voltage Readout 312028000 Totals Menu Commands Description Syrup Minutes SideBrix Gallons = a X Syrup MinutesDisplayed Error Conditions Programming Proper Refrigerant Type Into Unit ElectronicsDisplayed Error Conditions Control Panel ASS’Y Switches and Displayed Messages Control Panel ASS’Y SwitchesControl Panel Assembly Display Messages ‘‘SECURITY SWITCH.’’Freeze Cylinders Manual or Automatic Defrost Systems ‘‘SLEEP’’ Sleep Time Operation Faceplate Relief ValvesProduct Sample Valves Product Shutoff ValvesSyrup Flow Regulators Dispensing ValvesDispensed Product Conditions ‘‘OVERRUN’’, AS Applied to Frozen Carbonated BeveragesReplenishing Syrup Supply Operating CharacteristicsOperating Unit Cleaning and Sanitizing Cleaning Condenser CoilProduct Flavor Change Checking CO2 SupplyAdjustments Adjusting ‘‘VIS SET’’ Product Viscosity of Dispensed Product Cleaning CO2 GAS Check Valves Preparing Unit for SHIPPING, STORING, or Relocating Periodic InspectionTOP Panel Back PanelOpening and Closing Front Access Door Front Access PanelOpening Front Access Door Closing Front Access DoorOperating Controls Unit Internal Components SELF-CLOSING Dispensing Valve 312028000 Adjusting Plain Water Pressure Regulator Adjusting Carbonated Water Flow RateFreeze Cylinder Cutaway View Servicing Beater Motor Drive SHAFT/SEAL Assembly Beaters and Scraper Blades Installation Adjusting CO2 Regulators Adjusting Brix WATER-TO-SYRUP ‘‘RATIO’’ of Dispensed Product Sanitizing Syrup Systems Product Carbonation AdjustmentDaily Cleaning of Unit To disconnect soft drink tank from Unit syrup system 312028000 Yearly or After Water System Disruption Servicing Carbonator Water Pump Water Strainer ScreenLiquid Check Valve Assembly Servicing Carbonator Water Pump Double Liquid Check ValveReplenishing Syrup Supply Syrup Flavor Change Service and Maintenance SectionReplenishing CO2 Supply Water Strainer Screen and Double Liquid Check Valve Serviced Replacing Freeze Cylinder Beater Drive MotorAdjusting Carbonator Tank Liquid Level Ments in Small IncrementsCarbonator Liquid Level Control Switch Adjustment Refrigeration Flow Diagram Wiring Diagram This page Left Blank Intentionally Troubleshooting Control Panel Switches and Fault Messages Control Panel Switches Poorly Illuminated Display ONE or More FaultALL Fault Messages not a Cannot be DeactivatedALL Fault Message not ‘‘CO2 OUT’’ Fault Message‘‘H2O OUT’’ Fault Message Fault Message Goes onTroubleshooting Product Blender Tanks and Carbonator Troubleshooting Dispensed Product Frozen Product Consistency VariesExcessively FREEZE-UPIllustrated Parts Breakdown Unit Part NumbersOvercounter FCB POST-MIX Dispenser FCB POST-MIX Dispenser FCB POST-MIX Dispenser cont’d Name Secondary CO2 Regulator Components Secondary CO2 Regulator ASS’Y CO2 Regulator Assembly Blender and Tubing Components Tubing Assembly Carb Water Tubing Assembly Water Solenoid to Blender Solenoid Valve Assembly Blender Components Control BOX and Display Panel Components Faceplate Assembly Dispensing Valve Assembly Carbonator Components Carbonator Tank and Linkage Assembly Pump and Motor ASS’Y Beater Motor Drive SHAFT/SEAL ASS’Y Warranty This page Left Blank Intentionally One Cornelius Place Anoka, Minnesota 612 800