Cornelius R-404A REFRIGERANT Troubleshooting Control Panel Switches and Fault Messages

Page 70

TROUBLESHOOTING

IMPORTANT: Only qualified personnel should service internal components or electrical wiring.

WARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO2 system, stop dispensing, shut off the CO2 supply, then relieve the

system pressure before proceeding. If repairs are to be made to the refrigeration system, make sure electrical power is disconnected from the unit.

IMPORTANT: The following CO2 and liquid disconnects disconnecting and connecting procedure for soft drink tank replacement or filling soft drink tank in place must be performed in order as follows:

1.To disconnect soft drink tank from Unit syrup system.

A.Disconnect liquid disconnect from soft drink tank. NOTE - Disconnecting liquid quick disconnect from soft drink tank first prevents syrup from backflowing through Unit syrup flow regulator, which may alter regulator adjustment.

B.Second, disconnect CO2 quick disconnect from soft drink tank.

2.To connect soft drink tank into Unit syrup system.

A.First, connect CO2 quick disconnect to soft drink tank to pressurize tank.

B.Second, connect liquid quick disconnect to soft drink tank.

TROUBLESHOOTING CONTROL PANEL SWITCHES AND FAULT MESSAGES

Trouble

Probable Cause

Remedy

ONE OR MORE CONTROL

A. Flat cable not properly

A. Properly connect flat cable to

PANEL SWITCHES NOT

connected to control switch

control switch module or master

OPERATING.

module or master circuit

circuit board.

 

board.

 

B.Flat cable connected between control switch module and master circuit board pinched and shorted out or broken wire in cable.

B.Check cable for pinched or broken wire condition and repair or replace as necessary.

 

C. Inoperable switch(s) on control

C. Replace control panel switch

 

panel switch module.

 

module.

 

D. Master circuit board not

D.

Replace master circuit board.

 

operating properly.

 

 

 

 

 

 

ALL CONTROL PANEL

A. Electric power disconnected

A.

Restore electric power to Unit.

SWITCHES NOT OPERATING.

from Unit.

 

 

B.‘‘SECURITY SWITCH’’ has not been pressed to activate control panel switches.

B.Press and hold ‘‘SECURITY SWITCH’’ for 3 seconds to restore control panel switches to operation.

C. ‘‘SECURITY SWITCH’’

C. Replace control panel switch

inoperable (control switches

module.

deactivated).

 

D.Flat cable not properly connected to control switch module or master circuit board.

D.Properly connect flat cable to control switch module or master circuit board.

63

312028000

 

Image 70
Contents To the Installer Table of Contents Table of Contents cont’d Water Strainer Screen and Double Liquid Check Valve Programming Main Menu Selections Onto Message DisplayVIS Read Actual Viscosity Readout of Product Preparing Unit for SHIPPING, STORING, or RelocatingTroubleshooting Control Panel Switches and Fault Product Carbonation AdjustmentDaily Cleaning of Unit Sanitizing Syrup Systems ‘‘ERROR 1’’ or ‘‘ERROR 2’’ Fault Message Goes on DuringFreeze Cylinder Automatic Defrost Cycle does not Defrost Cycle does not Cancel After Pressing ‘‘CANCELList of Figures Table of Contents cont’d General Description Unit DescriptionTheory of Operation AccessoriesService Tools Generic Flavor TabsManual Defrost System Defrost SystemsAutomatic Defrost System ‘‘SLEEP’’ Sleep Time ‘‘WAKE UP’’ Wake UP TimeFlow Diagram This page Left Blank Intentionally Unpacking and Inspection Identification of LOOSE-SHIPPED PartsSelecting Location Electrical Power RequirementsHZ Unit Installing Drip Tray Supports Item 7 and Item Installing UnitInstalling Leveling Legs Installing Drip Tray Drain Hose KIT ItemInstalling Primary CO2 Regulator Assembly on CO2 Cylinder Connecting CO2 Source Line to Unit CO2 Inlet LineConnecting Electrical Power Circuit to the Unit Connecting City Plain Water Source Line to UnitElectrical BOX Adjusting Product Blender Tanks Secondary CO2 Turning on Electrical Power to UnitAdjusting Primary CO2 Regulator Adjusting Carbonator Secondary CO2 RegulatorHidden Security Switch Message Display Control Panel ASS’YFilling Freeze Cylinders with Product Checking Unit for SYRUP, CO2, or Plain Water LeaksAdjusting Beater Motor Current Either Side Placing Unit in Operating LocationSetting Clock Time of DAY Programming Main Menu Selection Onto Message DisplayMenu Selections Programming ‘‘DEFROST’’ Automatic Settings Into UnitMain Menu Selections DIP Switch Functions Switch FunctionProgramming ‘‘SLEEP’’ Sleep Time Into Unit Programming ‘‘WAKE UP’’ Wake UP Time Into Unit Programming Point of Sale Message DisplayAdjusting VIS SET Product Viscosity of Dispensed Product Master and Relay Circuit Board ‘‘VOLTAGE’’ Displayed Voltage Readout 312028000 Brix Totals Menu Commands DescriptionSyrup Minutes Side Gallons = a X Syrup MinutesDisplayed Error Conditions Programming Proper Refrigerant Type Into Unit ElectronicsDisplayed Error Conditions Control Panel ASS’Y Switches and Displayed Messages Control Panel ASS’Y SwitchesControl Panel Assembly Display Messages ‘‘SECURITY SWITCH.’’Freeze Cylinders Manual or Automatic Defrost Systems Product Sample Valves ‘‘SLEEP’’ Sleep Time OperationFaceplate Relief Valves Product Shutoff ValvesDispensed Product Conditions Syrup Flow RegulatorsDispensing Valves ‘‘OVERRUN’’, AS Applied to Frozen Carbonated BeveragesOperating Unit Operating CharacteristicsReplenishing Syrup Supply Product Flavor Change Cleaning and SanitizingCleaning Condenser Coil Checking CO2 SupplyAdjustments Adjusting ‘‘VIS SET’’ Product Viscosity of Dispensed Product Cleaning CO2 GAS Check Valves TOP Panel Preparing Unit for SHIPPING, STORING, or RelocatingPeriodic Inspection Back PanelOpening Front Access Door Opening and Closing Front Access DoorFront Access Panel Closing Front Access DoorOperating Controls Unit Internal Components SELF-CLOSING Dispensing Valve 312028000 Adjusting Plain Water Pressure Regulator Adjusting Carbonated Water Flow RateFreeze Cylinder Cutaway View Servicing Beater Motor Drive SHAFT/SEAL Assembly Beaters and Scraper Blades Installation Adjusting CO2 Regulators Adjusting Brix WATER-TO-SYRUP ‘‘RATIO’’ of Dispensed Product Daily Cleaning of Unit Product Carbonation AdjustmentSanitizing Syrup Systems To disconnect soft drink tank from Unit syrup system 312028000 Yearly or After Water System Disruption Servicing Carbonator Water Pump Water Strainer ScreenLiquid Check Valve Assembly Servicing Carbonator Water Pump Double Liquid Check ValveReplenishing Syrup Supply Replenishing CO2 Supply Service and Maintenance SectionSyrup Flavor Change Water Strainer Screen and Double Liquid Check Valve Serviced Replacing Freeze Cylinder Beater Drive MotorAdjusting Carbonator Tank Liquid Level Ments in Small IncrementsCarbonator Liquid Level Control Switch Adjustment Refrigeration Flow Diagram Wiring Diagram This page Left Blank Intentionally Troubleshooting Control Panel Switches and Fault Messages ALL Fault Messages not a Control Panel SwitchesPoorly Illuminated Display ONE or More Fault Cannot be Deactivated‘‘H2O OUT’’ Fault Message ALL Fault Message not‘‘CO2 OUT’’ Fault Message Fault Message Goes onTroubleshooting Product Blender Tanks and Carbonator Troubleshooting Dispensed Product Excessively Frozen ProductConsistency Varies FREEZE-UPIllustrated Parts Breakdown Unit Part NumbersOvercounter FCB POST-MIX Dispenser FCB POST-MIX Dispenser FCB POST-MIX Dispenser cont’d Name Secondary CO2 Regulator Components Secondary CO2 Regulator ASS’Y CO2 Regulator Assembly Blender and Tubing Components Tubing Assembly Carb Water Tubing Assembly Water Solenoid to Blender Solenoid Valve Assembly Blender Components Control BOX and Display Panel Components Faceplate Assembly Dispensing Valve Assembly Carbonator Components Carbonator Tank and Linkage Assembly Pump and Motor ASS’Y Beater Motor Drive SHAFT/SEAL ASS’Y Warranty This page Left Blank Intentionally One Cornelius Place Anoka, Minnesota 612 800