Cornelius R-404A REFRIGERANT Control Panel Assembly Display Messages, ‘‘Security Switch.’’

Page 35

’’AUTO 1’’ and ‘‘AUTO 2’’ Control Switches.

‘‘AUTO 1’’ and ‘‘AUTO 2’’ control switches, located on control panel assembly, are touch-type switches and require only pressing to activate. These switches are used to operate freeze cylinders beaters and refrigeration system after cylinders have been filled with product. Freeze cylinders beaters and refrigeration system may be stopped by pressing ‘‘OFF 1’’ or ‘‘OFF 2’’ switches.

‘‘OFF 1’’ and ‘‘OFF 2’’ Control Switches.

‘‘OFF 1’’ and ‘‘OFF 2’’ control switches, located on control panel, are touch-type switches and require only pressing to activate. These switches are used to stop freeze cylinders beaters and refrigeration system.

‘‘ERROR RESET’’ Control Switch.

‘‘ERROR RESET’’ control switch, located on control panel assembly, is a touch-type switch and requires only pressing to activate. ‘‘ERROR RESET’’ switch is used to restore normal operation after error within Unit (indicated by ‘‘ERROR 1’’ or ‘‘ERROR 2’’ on message display) has been corrected.

‘‘SECURITY SWITCH.’’

The Unit is equipped with a hidden ‘‘SECURITY SWITCH’’ located between ‘‘FILL 1’’ switch and ‘‘ERROR RESET’’ switch on the control panel assembly. Pressing in and holding the ‘‘SECURITY SWITCH’’ for 3 seconds deactivates the control switches preventing tampering with Unit normal operation. To reactivate control switches, press in and hold ‘‘SECURITY SWITCH’’ for 3 seconds.

CONTROL PANEL ASSEMBLY DISPLAY MESSAGES

(see Figure 3)

‘‘FILL 1’’ and ‘‘FILL 2’’ Fault Messages.

‘‘FILL 1’’ and ‘‘FILL 2’’ fault messages will appear on message display only when ‘‘FILL 1’’ and ‘‘FILL 2’’ control switches have been pressed and syrup systems sold-out floats have been filled with product. ‘‘FILL 1’’ and ‘‘FILL 2’’ fault messages will continue to be displayed until ‘‘AUTO BLEND 1’’ or ‘‘AUTO BLEND 2’’ control switches have been pressed to fill product blender tanks with product.

‘‘ERROR 1’’ and ‘‘ERROR 2’’ Fault Messages.

‘‘ERROR 1’’ and ‘‘ERROR 2’’ fault messages will appear on message display only if error within Unit has developed interrupting normal operation. Error will have to be located and corrected, then press ‘‘ERROR RESET’’ to restore normal operation. ‘‘ERROR 1’’ or ‘‘ERROR 2’’ fault message will disappear from display.

‘‘OFF 1’’ and ‘‘OFF 2’’ Fault Messages.

‘‘OFF 1’’ and ‘‘OFF 2’’ fault messages will appear on message display when either freeze cylinder beater is not operating.

‘‘H2O OUT’’ Fault Message.

The Unit plain water inlet system contains a water pressure switch. Should the plain water source to the Unit be disrupted or a water pressure drop occur, it will cause ‘‘H2O OUT’’ fault message to appear on message display. Unit will continue to operate for 1-1/2 minutes after ‘‘H2O OUT’’ fault message has appeared and if water pressure has not been restored or water pressure improved after 1-1/2 minutes, Unit operation will shut down. After plain water source has been restored or water pressure has improved, Unit will resume operation and ‘‘H2O OUT’’ fault message will disappear from message display.

312028000

28

Image 35
Contents To the Installer Table of Contents Table of Contents cont’d Preparing Unit for SHIPPING, STORING, or Relocating Programming Main Menu Selections Onto Message DisplayVIS Read Actual Viscosity Readout of Product Water Strainer Screen and Double Liquid Check Valve‘‘ERROR 1’’ or ‘‘ERROR 2’’ Fault Message Goes on During Product Carbonation AdjustmentDaily Cleaning of Unit Sanitizing Syrup Systems Troubleshooting Control Panel Switches and FaultList of Figures Defrost Cycle does not Cancel After Pressing ‘‘CANCELFreeze Cylinder Automatic Defrost Cycle does not Table of Contents cont’d Unit Description General DescriptionGeneric Flavor Tabs AccessoriesService Tools Theory of OperationAutomatic Defrost System Defrost SystemsManual Defrost System ‘‘WAKE UP’’ Wake UP Time ‘‘SLEEP’’ Sleep TimeFlow Diagram This page Left Blank Intentionally Identification of LOOSE-SHIPPED Parts Unpacking and InspectionHZ Unit Electrical Power RequirementsSelecting Location Installing Drip Tray Drain Hose KIT Item Installing UnitInstalling Leveling Legs Installing Drip Tray Supports Item 7 and ItemConnecting CO2 Source Line to Unit CO2 Inlet Line Installing Primary CO2 Regulator Assembly on CO2 CylinderElectrical BOX Connecting City Plain Water Source Line to UnitConnecting Electrical Power Circuit to the Unit Adjusting Carbonator Secondary CO2 Regulator Turning on Electrical Power to UnitAdjusting Primary CO2 Regulator Adjusting Product Blender Tanks Secondary CO2Control Panel ASS’Y Hidden Security Switch Message DisplayChecking Unit for SYRUP, CO2, or Plain Water Leaks Filling Freeze Cylinders with ProductPlacing Unit in Operating Location Adjusting Beater Motor Current Either SideProgramming Main Menu Selection Onto Message Display Setting Clock Time of DAYMain Menu Selections Programming ‘‘DEFROST’’ Automatic Settings Into UnitMenu Selections Programming ‘‘SLEEP’’ Sleep Time Into Unit Switch FunctionDIP Switch Functions Programming Point of Sale Message Display Programming ‘‘WAKE UP’’ Wake UP Time Into UnitAdjusting VIS SET Product Viscosity of Dispensed Product Master and Relay Circuit Board ‘‘VOLTAGE’’ Displayed Voltage Readout 312028000 Gallons = a X Syrup Minutes Totals Menu Commands DescriptionSyrup Minutes Side BrixProgramming Proper Refrigerant Type Into Unit Electronics Displayed Error ConditionsDisplayed Error Conditions Control Panel ASS’Y Switches Control Panel ASS’Y Switches and Displayed Messages‘‘SECURITY SWITCH.’’ Control Panel Assembly Display MessagesFreeze Cylinders Manual or Automatic Defrost Systems Product Shutoff Valves ‘‘SLEEP’’ Sleep Time OperationFaceplate Relief Valves Product Sample Valves‘‘OVERRUN’’, AS Applied to Frozen Carbonated Beverages Syrup Flow RegulatorsDispensing Valves Dispensed Product ConditionsReplenishing Syrup Supply Operating CharacteristicsOperating Unit Checking CO2 Supply Cleaning and SanitizingCleaning Condenser Coil Product Flavor ChangeAdjustments Adjusting ‘‘VIS SET’’ Product Viscosity of Dispensed Product Cleaning CO2 GAS Check Valves Back Panel Preparing Unit for SHIPPING, STORING, or RelocatingPeriodic Inspection TOP PanelClosing Front Access Door Opening and Closing Front Access DoorFront Access Panel Opening Front Access DoorOperating Controls Unit Internal Components SELF-CLOSING Dispensing Valve 312028000 Adjusting Carbonated Water Flow Rate Adjusting Plain Water Pressure RegulatorFreeze Cylinder Cutaway View Servicing Beater Motor Drive SHAFT/SEAL Assembly Beaters and Scraper Blades Installation Adjusting CO2 Regulators Adjusting Brix WATER-TO-SYRUP ‘‘RATIO’’ of Dispensed Product Sanitizing Syrup Systems Product Carbonation AdjustmentDaily Cleaning of Unit To disconnect soft drink tank from Unit syrup system 312028000 Servicing Carbonator Water Pump Water Strainer Screen Yearly or After Water System DisruptionServicing Carbonator Water Pump Double Liquid Check Valve Liquid Check Valve AssemblyReplenishing Syrup Supply Syrup Flavor Change Service and Maintenance SectionReplenishing CO2 Supply Water Strainer Screen and Double Liquid Check Valve Replacing Freeze Cylinder Beater Drive Motor ServicedMents in Small Increments Adjusting Carbonator Tank Liquid LevelCarbonator Liquid Level Control Switch Adjustment Refrigeration Flow Diagram Wiring Diagram This page Left Blank Intentionally Troubleshooting Control Panel Switches and Fault Messages Cannot be Deactivated Control Panel SwitchesPoorly Illuminated Display ONE or More Fault ALL Fault Messages not aFault Message Goes on ALL Fault Message not‘‘CO2 OUT’’ Fault Message ‘‘H2O OUT’’ Fault MessageTroubleshooting Product Blender Tanks and Carbonator Troubleshooting Dispensed Product FREEZE-UP Frozen ProductConsistency Varies ExcessivelyUnit Part Numbers Illustrated Parts BreakdownOvercounter FCB POST-MIX Dispenser FCB POST-MIX Dispenser FCB POST-MIX Dispenser cont’d Name Secondary CO2 Regulator Components Secondary CO2 Regulator ASS’Y CO2 Regulator Assembly Blender and Tubing Components Tubing Assembly Carb Water Tubing Assembly Water Solenoid to Blender Solenoid Valve Assembly Blender Components Control BOX and Display Panel Components Faceplate Assembly Dispensing Valve Assembly Carbonator Components Carbonator Tank and Linkage Assembly Pump and Motor ASS’Y Beater Motor Drive SHAFT/SEAL ASS’Y Warranty This page Left Blank Intentionally One Cornelius Place Anoka, Minnesota 612 800