Trouble  | 
  | Probable Cause  | 
  | Remedy  | 
ALL FAULT MESSAGE NOT | D.  | Master circuit board not  | D.  | Replace master circuit board.  | 
OPERATING (cont’d)  | 
  | operating.  | 
  | 
  | 
  | E.  | Fault message display module  | E.  | Replace fault message display  | 
  | 
  | not operating properly.  | 
  | module.  | 
  | 
  | 
  | 
  | 
  | 
‘‘CO2 OUT’’ FAULT MESSAGE | A.  | CO2 supply turned off or  | A.  | Open CO2 cylinder shutoff valve  | 
GOES ON DURING | 
  | exhausted.  | 
  | or replenish CO2 supply as  | 
OPERATION. | 
  | 
  | 
  | instructed.  | 
  | B.  | Primary CO2 regulator set too  | B.  | Adjust primary CO2 regulator as  | 
  | 
  | low.  | 
  | instructed.  | 
  | C.  | Inoperable CO2 pressure  | C.  | Replace CO2 pressure switch.  | 
  | 
  | switch.  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
‘‘H2O OUT’’ FAULT MESSAGE | A.  | Water supply turned off or  | A.  | Turn on water supply or check  | 
GOES ON DURING  | 
  | water pressure inadequate.  | 
  | water supply line pressure.  | 
OPERATION.  | 
  | 
  | 
  | 
  | 
  | B.  | Plugged water filter or water  | B.  | Change water filter or clean water  | 
  | 
  | pump strainer screen.  | 
  | pump strainer screen as  | 
  | 
  | 
  | 
  | instructed.  | 
  | C.  | Inoperative water pressure  | C.  | Replace water pressure switch.  | 
  | 
  | switch.  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
‘‘SYRUP 1’’ OR ‘‘SYRUP 2’’  | A.  | Soft drink tank empty.  | A.  | Replenish syrup supply as  | 
FAULT MESSAGE GOES ON | 
  | 
  | 
  | instructed.  | 
DURING OPERATION. | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
‘‘ERROR 1’’ OR ‘‘ERROR 2’’  | A.  | Error within Unit has  | A.  | Locate and correct error, then  | 
FAULT MESSAGE GOES ON  | 
  | developed interrupting normal  | 
  | press ‘‘ERROR RESET’’ switch to  | 
DURING OPERATION.  | 
  | operation.  | 
  | restore normal operation.  | 
  | 
  | 
  | 
  | 
  | 
FREEZE CYLINDER | A.  | Loose or broken electrical  | A.  | Repair electrical wires.  | 
AUTOMATIC DEFROST | 
  | wires.  | 
  | 
  | 
CYCLE DOES NOT | 
  | 
  | 
  | 
  | 
OPERATE. | 
  | 
  | 
  | 
  | 
  | B.  | Inoperable automatic defrost  | B.  | Replace master circuit board.  | 
  | 
  | timer.  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
UNIT DOES NOT GO OFF | A.  | Automatic defrost timer stuck  | A.  | Replace master circuit board.  | 
AUTOMATIC DEFROST  | 
  | in automatic defrost cycle.  | 
  | 
  | 
CYCLE. | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
MANUAL DEFROST CYCLE | A.  | Flat cable not properly  | A.  | Properly connect flat cable to  | 
DOES NOT OPERATE WHEN | 
  | connected to control switch  | 
  | control switch module or master  | 
‘‘DEFROST’’ SWITCH IS | 
  | module or master circuit  | 
  | circuit board.  | 
PRESSED. | 
  | board.  | 
  | 
  | 
  | B.  | Flat cable connected between  | B.  | Check cable for pinched or  | 
  | 
  | control switch module and  | 
  | broken wire condition and repair  | 
  | 
  | master circuit board pinched  | 
  | or replace as necessary.  | 
  | 
  | and shorted out or broken wire  | 
  | 
  | 
  | 
  | in cable.  | 
  | 
  | 
  | C.  | Inoperable ‘‘DEFROST’’ switch  | C. Replace control panel switch  | |
  | 
  | on control panel switch  | 
  | module.  | 
  | 
  | module.  | 
  | 
  | 
  | D.  | Loose or broken wire.  | D.  | Repair wire.  | 
  | 
  | 
  | 
  | 
  | 
65  | 312028000 | 
  |