Spin Fryer I12 Cooking Computer
Pitco P/N 60149505
3To Change Options Level 2 ( for the Store Manager):
The display must show from section 2 to change these options. When the
product key [0] is pressed, the display will show | . Indicator |
lights above product keys will illuminate to represent options that may be changed. Each option listed below uses the product key [0] to toggle or scroll through available choices in the display.
When the correct value is displayed, press the key to save choice. The display will again
return to for another option selection.
0 |
3.1Fahrenheit or Celsius Display:
The Controller will display temperatures in the Fahrenheit or Celsius scales. The default scale is °F.
With display showing , press the product key [0].
Display shows | . |
Press product key 1, display shows [DEGREE n] [F OR C], where “n” is the current setting.
Use the product key [0] to scroll through choices (F or C). Press key to save choice.
Display shows .
1 |
3.2Password Change or Required?
With factory settings, an operator password is not required to enter programming Levels 1 and 2. The password may be activated or changed in these steps.
With display showing , press the product key [0].
Display will show | . |
Press product key 2, display shows [SET PAS] [NEW PASS]. Use the product key [0] to
scroll through choices [NO PASS] or [PASS REQ]. Press key to save choice.
If [NO PASS] is selected Display returns to .
2 |
If [PASS REQ]. is selected, display will show [PASSnnnn] [NEW PASS] to prompt for new password. Displayed value “nnnn” is the current password. Use the product keys for numeric
entry to change password. Press [P] key to save choice. Display then shows .
Note: The factory default password (6684) will always work even if a different password is selected here.
Page 10 of 28 |