Pitco Frialator L22-355 service manual To Change Options Level 2 for the Store Manager

Page 10

Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

3To Change Options Level 2 ( for the Store Manager):

The display must show from section 2 to change these options. When the

product key [0] is pressed, the display will show

. Indicator

lights above product keys will illuminate to represent options that may be changed. Each option listed below uses the product key [0] to toggle or scroll through available choices in the display.

When the correct value is displayed, press the key to save choice. The display will again

return to for another option selection.

0

3.1Fahrenheit or Celsius Display:

The Controller will display temperatures in the Fahrenheit or Celsius scales. The default scale is °F.

With display showing , press the product key [0].

Display shows

.

Press product key 1, display shows [DEGREE n] [F OR C], where “n” is the current setting.

Use the product key [0] to scroll through choices (F or C). Press key to save choice.

Display shows .

1

3.2Password Change or Required?

With factory settings, an operator password is not required to enter programming Levels 1 and 2. The password may be activated or changed in these steps.

With display showing , press the product key [0].

Display will show

.

Press product key 2, display shows [SET PAS] [NEW PASS]. Use the product key [0] to

scroll through choices [NO PASS] or [PASS REQ]. Press key to save choice.

If [NO PASS] is selected Display returns to .

2

If [PASS REQ]. is selected, display will show [PASSnnnn] [NEW PASS] to prompt for new password. Displayed value “nnnn” is the current password. Use the product keys for numeric

entry to change password. Press [P] key to save choice. Display then shows .

Note: The factory default password (6684) will always work even if a different password is selected here.

L22-355 Rev 1

Page 10 of 28

Image 10
Contents For Pitco P/N 60149505 Spin Fryer Important Information for Future ReferenceTo Enter Programming Level 1 for the Store Manager Spin Fryer I12 Cooking Computer To turn the appliance OFF To turn the appliance onTo start a cook To cancel a cook To check Actual and Set temperaturesAutomatic Boil Entry Water Detection To perform a Boil Out operationManual Boil Entry To Set Cook Temperature To Enter Programming Level 1 for the Store ManagerShake Time Cook TimeHold Time Spin Rate Hold Pre-AlarmSpin Time To Exit Level 1 programmingTo Change Options Level 2 for the Store Manager Password Change or Required?Fahrenheit or Celsius Display Language Selection Beeper ON/OFFMelt Cycle Type Recovery Test Value To Enter Programming Level 3 for the Technician Offset the Temperature DisplayMelt Cycle on Time Recovery Times Minimum on and OFF Cycle TimeDiagnostic Menu Entry Function Description ButtonReady Level Temperature Operating RangeMore Service Menu Entry Instant On ToggleCancel Duration Shake Alarm DurationHold Alarm Duration Configuration ValueSet Network Address Factory ResetStanding Pilot Toggle To Exit Programming LevelFactory Menu Level 4 for the Technician Offset Temperature DisplayPitco Collect toggle Operating Temperature Range Recovery Test ValuesHigh Limit Value Spin Diagnostics Used if object becomes stuck during spinning12.1 Control ID Display Test On/OffMore Factory Menu Entry To Exit Factory Menu LevelOther Displays System / FailurePage Mechanical Dimensions Electrical Connections at Left and Right connectors J1Left Inputs Type NominalOhms Probe Resistance ChartProbe Resistance in 5F Increments Probe ResistanceMailing Address P.O. BOX 501, CONCORD, NH