Pitco Frialator L22-355 Spin Diagnostics, Used if object becomes stuck during spinning

Page 21

Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

5.10Spin Diagnostics

The Spin Diagnostic menu is used to determine the functionality of controller outputs and inputs. By exercising each output and examining inputs, a determination can be made if an appliance problem is controller related. In the diagnostic menu, product keys are assigned specific inputs or outputs.

All outputs in the ON state should produce 22VDC at the appropriate pins on the controller connector. Controller inputs can be verified by the on or off state of the indicator above the product key. This section details the process of checking each input and output.

With display showing [SPIN][DIAGNOST]

press product key 9. The screen will show

The following list describes the function of each key in the spin diagnostic mode.

Function

Description

Button

5.10.1

Motor On/Off

Toggles spin motor on and off.

L

 

 

 

 

5.10.2

Motor Speed - Increase

Increases the spin motor’s speed in 10 RPM

1

 

 

increments up to a maximum of 500 RPM.

 

5.10.3

Motor Speed Decrease

Decreases the spin motor’s speed in 10 RPM

2

 

 

increments up to a minimum of 60 RPM.

 

5.10.4

Spin Direction

Toggles the motor’s spin direction from spinning

3

 

 

clockwise to counter-clockwise or vice-verse. To be

 

 

 

used if object becomes stuck during spinning.

 

 

 

 

 

5.10.5

Door Open

Activates the indicator light to show the door’s current

5

 

 

position.

 

5.10.6

Cook Position Indicator

Activates the indicator light to show the basket lift’s

6

 

 

current position. Shows CLOSED if not in the stated

 

 

 

position.

 

 

 

 

 

5.10.7

Load Position Indicator

Activates the indicator light to show the basket lift’s

7

 

 

current position. Shows CLOSED if not in the stated

 

 

 

position.

 

5.10.8

Spin Position Indicator

Activates the indicator light to show the basket lift’s

8

 

 

current position. Shows CLOSED if not in the stated

 

 

 

position.

 

 

 

 

 

5.10.9

Basket Lift Position (Cook)

Moves the basket lift into the cook position.

9

 

 

 

 

5.10.10

Basket Lift Position (Load)

Moves the basket lift into the load position.

0

 

 

 

 

5.10.11

Basket Lift Position (Spin)

Moves the basket lift into the spin position.

R

 

 

 

 

Note: LSW – Limit Switch. This is the black collar located on the basket lift actuator.

Press the display will return to

.

Page 21 of 28

L22-355 Rev 1

Image 21
Contents Important Information for Future Reference For Pitco P/N 60149505 Spin FryerTo Enter Programming Level 1 for the Store Manager Spin Fryer I12 Cooking Computer To turn the appliance on To turn the appliance OFFTo start a cook To check Actual and Set temperatures To cancel a cookTo perform a Boil Out operation Automatic Boil Entry Water DetectionManual Boil Entry To Enter Programming Level 1 for the Store Manager To Set Cook TemperatureCook Time Shake TimeHold Time Spin Time Hold Pre-AlarmSpin Rate To Exit Level 1 programmingPassword Change or Required? To Change Options Level 2 for the Store ManagerFahrenheit or Celsius Display Beeper ON/OFF Language SelectionMelt Cycle Type Recovery Test Value Offset the Temperature Display To Enter Programming Level 3 for the TechnicianMelt Cycle on Time Minimum on and OFF Cycle Time Recovery TimesFunction Description Button Diagnostic Menu EntryMore Service Menu Entry Temperature Operating RangeReady Level Instant On ToggleHold Alarm Duration Shake Alarm DurationCancel Duration Configuration ValueStanding Pilot Toggle Factory ResetSet Network Address To Exit Programming LevelOffset Temperature Display Factory Menu Level 4 for the TechnicianPitco Collect toggle Recovery Test Values Operating Temperature RangeHigh Limit Value Used if object becomes stuck during spinning Spin DiagnosticsMore Factory Menu Entry Test On/Off12.1 Control ID Display To Exit Factory Menu LevelSystem / Failure Other DisplaysPage Mechanical Dimensions J1Left Inputs Type Nominal Electrical Connections at Left and Right connectorsProbe Resistance in 5F Increments Probe Resistance ChartOhms Probe ResistanceMailing Address P.O. BOX 501, CONCORD, NH