4To Enter Programming Level 3 (for the Technician)
With no cook timers running, displays will show one of the following displays:
;
, or
.
Press the key. The left display will show . The right display will be blank.
Enter password entry.
Level 3 Password |
| ||
6 | 6 | 8 | 5 |
using the product keys as a numeric keypad for
Display will show | . Product key indicators will |
illuminate to prompt operator to select a key. This section details parameters that may be changed in Level 3 programming.
4.1Offset the Temperature Display:
This adjustment allows the displayed temperature value to be offset to reflect the true center vat temperature while reading the probe tip temperature. Default value is +2. With zero value set, displayed values are the probe temperature.
With display showing | press product key 1. |
Display shows [OFF nn F] [DEGREES], where “nn” is the value of the adjustment.
Negative values are preceded with a minus sign. To change this value, use the product keys for numeric entry of a new value.
1 |
Press the key. Display will show [POSITIVE] [DEGREES]. Use the product key to scroll choices (Positive or Negative value).
After selection, press the | key. Display shows | . |
Note: Computer Display Temp – Center Vat Temp = Offset
4.2Melt Cycle ON Time
With display showing | press product key 2. |
Display shows [MLTON :nn] [MELT ON], where “nn” is the value, in seconds, of time for a melt cycle heat pulse.
To change this value, use the product keys for numeric entry of a new value.
Press the | key. Display returns to | . |