Pitco Frialator L22-355 service manual Electrical Connections at Left and Right connectors

Page 26

Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

8Electrical Connections at LEFT and RIGHT connectors):

As viewed from the rear of the control.

J1(Left)

Inputs

Type

Nominal

Notes:

 

 

 

 

 

1

ACH

PWR

24VAC

24VAC +20% -15% 50/60Hz.

2

ACN

PWR

24VACN

24VAC Return.

3

PROBE+

Thermistor

Resistance varies with vat temperature. 942 Ohms

4

PROBE-

Proble

@ 350°F

 

5

DVI

IN

24VAC

Drain Valve Interlock

6

HFB

IN

24VAC

Heat Feed Back

7

24VDC COM

IN

24VDC

DC Returm

8

HD

OUT

24VDC

Heat Demand

9

SO/xFER

OUT

24VDC

Side ON or XFER

10

RBL

OUT

24VDC

Right Basket Lift

11

LBL

OUT

24VDC

Left Basket Lift

12

AC2

PWR

24VAC

Aux Power Input

Tip: Use the diagnostic menu to verify operation of outputs, and inputs.

L22-280 Rev 1

Page 26 of 28

Image 26
Contents For Pitco P/N 60149505 Spin Fryer Important Information for Future ReferenceTo Enter Programming Level 1 for the Store Manager Spin Fryer I12 Cooking Computer To start a cook To turn the appliance onTo turn the appliance OFF To cancel a cook To check Actual and Set temperaturesManual Boil Entry To perform a Boil Out operationAutomatic Boil Entry Water Detection To Set Cook Temperature To Enter Programming Level 1 for the Store ManagerHold Time Cook TimeShake Time Spin Rate Hold Pre-AlarmSpin Time To Exit Level 1 programmingFahrenheit or Celsius Display Password Change or Required?To Change Options Level 2 for the Store Manager Melt Cycle Type Beeper ON/OFFLanguage Selection Recovery Test Value Melt Cycle on Time Offset the Temperature DisplayTo Enter Programming Level 3 for the Technician Recovery Times Minimum on and OFF Cycle TimeDiagnostic Menu Entry Function Description ButtonReady Level Temperature Operating RangeMore Service Menu Entry Instant On ToggleCancel Duration Shake Alarm DurationHold Alarm Duration Configuration ValueSet Network Address Factory ResetStanding Pilot Toggle To Exit Programming LevelPitco Collect toggle Offset Temperature DisplayFactory Menu Level 4 for the Technician High Limit Value Recovery Test ValuesOperating Temperature Range Spin Diagnostics Used if object becomes stuck during spinning12.1 Control ID Display Test On/OffMore Factory Menu Entry To Exit Factory Menu LevelOther Displays System / FailurePage Mechanical Dimensions Electrical Connections at Left and Right connectors J1Left Inputs Type NominalOhms Probe Resistance ChartProbe Resistance in 5F Increments Probe ResistanceMailing Address P.O. BOX 501, CONCORD, NH