Pitco Frialator L22-355 service manual To Enter Programming Level 1 for the Store Manager

Page 7

Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

2To Enter Programming Level 1 (for the Store Manager):

Note: The factory default setting for this control does not require a password to be entered. However, the operator password requirement and value may be changed in section 3.2. Entry of a password when NOT required will not interfere with the programming process.

With no cook timers running, displays will show one of the following displays:

, or

. Press the

key.

;

If display shows:

 

 

 

 

 

 

, a password is required.

Level 1& 2 Password

6

6

8

4

Enter password

 

 

using the product keys as

a numeric keypad for entry. With correct password entry, display

will show .

If display shows:

; you do not need

to enter a password.

From the display, continue with this section or go to section 3, or 4.

2.1To Set Cook Temperature:

Press the

key once. The display will show [SET xxxF] [TEMP] or [SET xxxC] [TEMP],

where “xxx” is the temperature setting.

Use the product keys for numeric entry to adjust the current setting. Press the key to

save setting. Display now shows . To exit here, press again, or continue.

Page 7 of 28

L22-355 Rev 1

Image 7
Contents Important Information for Future Reference For Pitco P/N 60149505 Spin FryerTo Enter Programming Level 1 for the Store Manager Spin Fryer I12 Cooking Computer To turn the appliance OFF To turn the appliance onTo start a cook To check Actual and Set temperatures To cancel a cookAutomatic Boil Entry Water Detection To perform a Boil Out operationManual Boil Entry To Enter Programming Level 1 for the Store Manager To Set Cook TemperatureShake Time Cook TimeHold Time To Exit Level 1 programming Hold Pre-AlarmSpin Time Spin RateTo Change Options Level 2 for the Store Manager Password Change or Required?Fahrenheit or Celsius Display Language Selection Beeper ON/OFFMelt Cycle Type Recovery Test Value To Enter Programming Level 3 for the Technician Offset the Temperature DisplayMelt Cycle on Time Minimum on and OFF Cycle Time Recovery TimesFunction Description Button Diagnostic Menu EntryInstant On Toggle Temperature Operating RangeMore Service Menu Entry Ready LevelConfiguration Value Shake Alarm DurationHold Alarm Duration Cancel DurationTo Exit Programming Level Factory ResetStanding Pilot Toggle Set Network AddressFactory Menu Level 4 for the Technician Offset Temperature DisplayPitco Collect toggle Operating Temperature Range Recovery Test ValuesHigh Limit Value Used if object becomes stuck during spinning Spin DiagnosticsTo Exit Factory Menu Level Test On/OffMore Factory Menu Entry 12.1 Control ID DisplaySystem / Failure Other DisplaysPage Mechanical Dimensions J1Left Inputs Type Nominal Electrical Connections at Left and Right connectorsProbe Resistance Probe Resistance ChartProbe Resistance in 5F Increments OhmsMailing Address P.O. BOX 501, CONCORD, NH