Pitco Frialator L22-355 Recovery Test Values, Operating Temperature Range, High Limit Value

Page 20

Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

5.5Recovery Test Values

This menu is identical to Recovery Times section 4.4 except instead of [SERVICE].

is displayed

4

5.6Diagnostic Menu Entry

This menu is identical to Diagnostic Menu section 4.5 except is displayed instead of [SERVICE].

5.7Ready Level

This menu is identical to Ready Level section 4.6 except

is

displayed instead of [SERVICE].

5.8Operating Temperature Range

This menu is identical to Temperature Operating Range section 4.7 except is displayed instead of [SERVICE].

5.9High Limit Value

With display showing

press product key 8.

Pressing product key 8 forces the control to display the temperature above the set temperature, where the high limit alarm will sound. This is a display only value, this value cannot be changed with a keypad entry.

Press the

key. Display now shows

.

Note: Factory default value is 40°F over set temperature, or 410°F absolute, whichever is less.

5

6

7

8

L22-355 Rev 1

Page 20 of 28

Image 20
Contents For Pitco P/N 60149505 Spin Fryer Important Information for Future ReferenceTo Enter Programming Level 1 for the Store Manager Spin Fryer I12 Cooking Computer To start a cook To turn the appliance onTo turn the appliance OFF To cancel a cook To check Actual and Set temperaturesManual Boil Entry To perform a Boil Out operationAutomatic Boil Entry Water Detection To Set Cook Temperature To Enter Programming Level 1 for the Store ManagerHold Time Cook TimeShake Time Hold Pre-Alarm Spin TimeSpin Rate To Exit Level 1 programmingFahrenheit or Celsius Display Password Change or Required?To Change Options Level 2 for the Store Manager Melt Cycle Type Beeper ON/OFFLanguage Selection Recovery Test Value Melt Cycle on Time Offset the Temperature DisplayTo Enter Programming Level 3 for the Technician Recovery Times Minimum on and OFF Cycle TimeDiagnostic Menu Entry Function Description ButtonTemperature Operating Range More Service Menu EntryReady Level Instant On ToggleShake Alarm Duration Hold Alarm DurationCancel Duration Configuration ValueFactory Reset Standing Pilot ToggleSet Network Address To Exit Programming LevelPitco Collect toggle Offset Temperature DisplayFactory Menu Level 4 for the Technician High Limit Value Recovery Test ValuesOperating Temperature Range Spin Diagnostics Used if object becomes stuck during spinningTest On/Off More Factory Menu Entry12.1 Control ID Display To Exit Factory Menu LevelOther Displays System / FailurePage Mechanical Dimensions Electrical Connections at Left and Right connectors J1Left Inputs Type NominalProbe Resistance Chart Probe Resistance in 5F IncrementsOhms Probe ResistanceMailing Address P.O. BOX 501, CONCORD, NH