Pitco Frialator L22-355 Heat Demand Profile, Shake Alarm Duration, Hold Alarm Duration

Page 17

Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

4.8.2Heat Demand Profile

With display showing

, press product key 3. Display will show

[xxxxxxx] [HEAT DEM], where xxxxxxx may be one of 6 heat control profiles listed below.

1.[GENERIC 1] for gas fired fryer appliance. This is the factory default.

2.[GENERIC 2] for electric fryer appliances, and model SGH50.

3.[TEST] for use in special cook testing, do not select this setting for normal operations.

Use product key [0] change value, then press the to save choice Display returns to

.

4.8.3Shake Alarm Duration

With display showing

, press product key 4. Display will show

[SH-DUR:nn] [DURATION], where “nn” is the time in seconds the shake alarm will sound. Use

product keys for numeric entry of desired value, then press the

to save choice. Display

returns to

.

 

3

4

4.8.4Hold Alarm Duration

With the display showing

, press product key 5. Display will

show [HD-DUR:nn] [DURATION], where “nn” is the time in seconds the hold alarm will sound.

Use product keys for numeric entry of desired value, then press the to save choice.

Display returns to

.

4.8.5Cancel Duration

With the display showing

, press product key 6. Display will

show [CANCEL:nn] [DELAY] , where “nn” is the time in seconds the operators must press a product key to cancel a cook. Use product keys for numeric entry of desired value, then press

the

to save choice. Display returns to

. Default value is

2 seconds.

 

5

6

4.8.6Configuration Value

With display showing

, press product key 7. Display will show

[CFG hhhh], where “hhhh” is a hexadecimal checksum of the configuration memory contained in the controller. Modifications to any part of the setup of this control will change the check

sum value. Press the

display will return to

.

7

Page 17 of 28

L22-355 Rev 1

Image 17
Contents Important Information for Future Reference For Pitco P/N 60149505 Spin FryerTo Enter Programming Level 1 for the Store Manager Spin Fryer I12 Cooking Computer To start a cook To turn the appliance onTo turn the appliance OFF To check Actual and Set temperatures To cancel a cookManual Boil Entry To perform a Boil Out operationAutomatic Boil Entry Water Detection To Enter Programming Level 1 for the Store Manager To Set Cook TemperatureHold Time Cook TimeShake Time Spin Time Hold Pre-AlarmSpin Rate To Exit Level 1 programmingFahrenheit or Celsius Display Password Change or Required?To Change Options Level 2 for the Store Manager Melt Cycle Type Beeper ON/OFFLanguage Selection Recovery Test Value Melt Cycle on Time Offset the Temperature DisplayTo Enter Programming Level 3 for the Technician Minimum on and OFF Cycle Time Recovery TimesFunction Description Button Diagnostic Menu EntryMore Service Menu Entry Temperature Operating RangeReady Level Instant On ToggleHold Alarm Duration Shake Alarm DurationCancel Duration Configuration ValueStanding Pilot Toggle Factory ResetSet Network Address To Exit Programming LevelPitco Collect toggle Offset Temperature DisplayFactory Menu Level 4 for the Technician High Limit Value Recovery Test ValuesOperating Temperature Range Used if object becomes stuck during spinning Spin DiagnosticsMore Factory Menu Entry Test On/Off12.1 Control ID Display To Exit Factory Menu LevelSystem / Failure Other DisplaysPage Mechanical Dimensions J1Left Inputs Type Nominal Electrical Connections at Left and Right connectorsProbe Resistance in 5F Increments Probe Resistance ChartOhms Probe ResistanceMailing Address P.O. BOX 501, CONCORD, NH