Spin Fryer I12 Cooking Computer
Pitco P/N 60149505
4.5Diagnostic Menu Entry
The diagnostic menu is used to determine the functionality of controller outputs and inputs. By exercising each output and examining inputs, a determination can be made if an appliance problem is controller related. In the diagnostic menu, product keys are assigned specific inputs or outputs.
All outputs in the ON state should produce 22VDC at the appropriate pins on the controller connector. Controller inputs can be verified by the on or off state of the indicator above the product key. This section details the process of checking each input and output.
With display showing | press product key 5. |
Display will show [DIAGNOST] [DIAGNOST].
5 |
The following list describes the function of each key in the diagnostic mode.
Function | Description | Button | |
|
|
|
|
4.5.1 | Basket Lift Output | Toggles basket lift output on and off. | 1 |
|
| Display will show [BASKET] |
|
4.5.2 | Brake | Toggles basket lift brake output on and off. | 2 |
|
| Display will show [Brake] [Brake] |
|
4.5.3 | Heat Demand Output | Hold the product key 3 to force Heat Demand output | 3 |
|
| ON. Display will show [HEAT DEM]. Releasing the |
|
|
| key will force output OFF. |
|
|
|
|
|
4.5.4 | Side On Output | Toggles the “Side ON” output ON. Display will show | 4 |
|
| [SIDE ON] Press again to toggle output OFF. |
|
4.5.5 | Drain Switch Input | Display will show state of the Drain Valve input. | 5 |
|
| Display will show [DRN ON (or OFF)]. Product key 5 |
|
|
| indicator shows the ON or OFF state of the input. |
|
|
|
|
|
4.5.6 | Lamp Test | All display indicators will be forced on. The purpose is | 6 |
|
| to reveal |
|
4.5.7 | Heat Feedback Input | Display will show state of the Heat Feedback input [FB | 7 |
|
| xxx], where xxx is ON or OFF. Key 7 indicator shows |
|
|
| the ON or OFF state of this input. |
|
|
|
|
|
4.5.8Exit Diagnostic Menu
To exit diagnostic menu, press the key. Display will return to Other service menu items may be selected for changes.
.
To return to programming, press the key again. Display will show . Other settings can be made in section 2.
To return to normal operations, press the key again. Display will show one of the
normal displays:
;
, or
.
Page 15 of 28 |