Pitco Frialator L22-355 service manual Spin Fryer I12 Cooking Computer

Page 3

 

 

Spin Fryer I12 Cooking Computer

 

 

Pitco P/N 60149505

4.8.2

Heat Demand Profile

17

4.8.3

Shake Alarm Duration

17

4.8.4

Hold Alarm Duration

17

4.8.5

Cancel Duration

17

4.8.6

Configuration Value

17

4.8.7

Factory Reset

18

4.8.8

Standing Pilot Toggle

18

4.8.9

Set Network Address

18

4.9To Exit Programming Level 3 ____________________________________________________ 18

5 Factory Menu Level 4 (for the Technician)

19

5.1Pitco Collect (toggle) __________________________________________________________ 19

5.2Offset Temperature Display _____________________________________________________ 19

5.3Melt Cycle ON Time ___________________________________________________________ 19

5.4Minimum ON and OFF Cycle Time________________________________________________ 19

5.5Recovery Test Values _________________________________________________________ 20

5.6Diagnostic Menu Entry _________________________________________________________ 20

5.7Ready Level _________________________________________________________________ 20

5.8Operating Temperature Range___________________________________________________ 20

5.9High Limit Value ______________________________________________________________ 20

5.10Spin Diagnostics ____________________________________________________________ 21

5.10.1

Motor On/Off

21

5.10.2

Motor Speed - Increase

21

5.10.3

Motor Speed Decrease

21

5.10.4

Spin Direction

21

5.10.5

Door Open

21

5.10.6

Cook Position Indicator

21

5.10.7

Load Position Indicator

21

5.10.8

Spin Position Indicator

21

5.10.9

Basket Lift Position (Cook)

21

5.10.10

Basket Lift Position (Load)

21

5.10.11

Basket Lift Position (Spin)

21

5.11Test On/Off ________________________________________________________________ 22

5.12More Factory Menu Entry _____________________________________________________ 22

5.12.1

Control ID Display

22

5.12.2

Set Network Address

22

5.13To Exit Factory Menu (Level 4): ________________________________________________ 22

6

Other Displays:

23

7

Mechanical Dimensions:

25

8

Electrical Connections at LEFT and RIGHT connectors):

26

9

Probe Resistance Chart:

27

Page 3 of 28

L22-355 Rev 1

Image 3
Contents Important Information for Future Reference For Pitco P/N 60149505 Spin FryerTo Enter Programming Level 1 for the Store Manager Spin Fryer I12 Cooking Computer To turn the appliance on To turn the appliance OFFTo start a cook To check Actual and Set temperatures To cancel a cookTo perform a Boil Out operation Automatic Boil Entry Water DetectionManual Boil Entry To Enter Programming Level 1 for the Store Manager To Set Cook TemperatureCook Time Shake TimeHold Time To Exit Level 1 programming Hold Pre-AlarmSpin Time Spin RatePassword Change or Required? To Change Options Level 2 for the Store ManagerFahrenheit or Celsius Display Beeper ON/OFF Language SelectionMelt Cycle Type Recovery Test Value Offset the Temperature Display To Enter Programming Level 3 for the TechnicianMelt Cycle on Time Minimum on and OFF Cycle Time Recovery TimesFunction Description Button Diagnostic Menu EntryInstant On Toggle Temperature Operating RangeMore Service Menu Entry Ready LevelConfiguration Value Shake Alarm DurationHold Alarm Duration Cancel DurationTo Exit Programming Level Factory ResetStanding Pilot Toggle Set Network AddressOffset Temperature Display Factory Menu Level 4 for the TechnicianPitco Collect toggle Recovery Test Values Operating Temperature RangeHigh Limit Value Used if object becomes stuck during spinning Spin DiagnosticsTo Exit Factory Menu Level Test On/OffMore Factory Menu Entry 12.1 Control ID DisplaySystem / Failure Other DisplaysPage Mechanical Dimensions J1Left Inputs Type Nominal Electrical Connections at Left and Right connectorsProbe Resistance Probe Resistance ChartProbe Resistance in 5F Increments OhmsMailing Address P.O. BOX 501, CONCORD, NH