Pitco Frialator L22-355 service manual To cancel a cook, To check Actual and Set temperatures

Page 5

Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

1.4To cancel a cook:

Press and hold the product key to cancel a running cook. The controller displays

. Press the ‘6’ button to spin the basket and

the ‘0’ button to not spin the basket. If neither button is pressed after 15 second

the system will default back to

1.5To check Actual and Set temperatures:

state.

To view the actual vat temperature, press the

key. The display will show

or

, where “F’ is Fahrenheit, and “C” is Celsius. After a few moments, the display will

return to [READY], [MELT ], or [HEATING] if no cooks are running. [CKn mm:ss] will display for any cooks still running.

To view the set temperature, press the

key twice. The display will show

or

, where “F’ is Fahrenheit, and “C” is Celsius. After a few moments, the display will

return to [READY], [MELT ], or [HEATING] , or, [CKn mm:ss] for any cook still running.

1.6To View Current Settings for Cook, Shake, Hold, and Hold Pre-Alarm:

To view the current settings for any product key, press the key, followed by the desired

product key. The display will show [CKn mm:ss], followed by [SHn mm:ss], then [HDn mm:ss], ending with [PA4 mm:ss]. Where “n” is the key number, and “mm:ss” is the time setting.

After a few moments, the display will return to or, [CKn mm:ss] for any cook still running.

Typical displays using key 4 as an example:

Key 4 Cook Time [CK4] is set for 3 minutes and 28 seconds.

;

, or

,

Key 4 Shake Time [SH4] is set for 2 minutes and 00 seconds before the end of the Cook. When this time is met the cook will be suspended and basket will spin for 10 seconds unless Spin Time [ST4] is less than 10 seconds, then they are equal. The basket then returns to the cooking position. Default value is 00:00, or inactive.

Key 4 Hold Time [HD4] is set for 2:00 minutes. This is the amount of time cooked product may sit in holding bins before a new batch is started. Default value is 00:00, or inactive.

Key 4 Hold Pre-Alarm [PA4] is set for 00:00 and is inactive (default setting). When activated his alarm warns the operators that the Hold Time is about to run out.

Key 4 Spin Time [ST4] is set for 00:30. When activated this is the time that the basket will spin for at the end of the cook. Default value is 00:30.

Key 4 Spin Rate [SR4] is set to 350. When active this is the speed at which the basket will spin.

Default value is 350, or inactive.

+

4

Page 5 of 28

L22-280 Rev 1

Image 5
Contents Important Information for Future Reference For Pitco P/N 60149505 Spin FryerTo Enter Programming Level 1 for the Store Manager Spin Fryer I12 Cooking Computer To start a cook To turn the appliance onTo turn the appliance OFF To check Actual and Set temperatures To cancel a cookManual Boil Entry To perform a Boil Out operationAutomatic Boil Entry Water Detection To Enter Programming Level 1 for the Store Manager To Set Cook TemperatureHold Time Cook TimeShake Time Spin Time Hold Pre-AlarmSpin Rate To Exit Level 1 programmingFahrenheit or Celsius Display Password Change or Required?To Change Options Level 2 for the Store Manager Melt Cycle Type Beeper ON/OFFLanguage Selection Recovery Test Value Melt Cycle on Time Offset the Temperature DisplayTo Enter Programming Level 3 for the Technician Minimum on and OFF Cycle Time Recovery TimesFunction Description Button Diagnostic Menu EntryMore Service Menu Entry Temperature Operating RangeReady Level Instant On ToggleHold Alarm Duration Shake Alarm DurationCancel Duration Configuration ValueStanding Pilot Toggle Factory ResetSet Network Address To Exit Programming LevelPitco Collect toggle Offset Temperature DisplayFactory Menu Level 4 for the Technician High Limit Value Recovery Test ValuesOperating Temperature Range Used if object becomes stuck during spinning Spin DiagnosticsMore Factory Menu Entry Test On/Off12.1 Control ID Display To Exit Factory Menu LevelSystem / Failure Other DisplaysPage Mechanical Dimensions J1Left Inputs Type Nominal Electrical Connections at Left and Right connectorsProbe Resistance in 5F Increments Probe Resistance ChartOhms Probe ResistanceMailing Address P.O. BOX 501, CONCORD, NH