Pitco Frialator L22-355 service manual Other Displays, System / Failure

Page 23

Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

6Other Displays:

Open probe detection is standard on all Pitco controls. If probe is detected open, normal heating and cooking activities are suspended.

This display warns operators that the vat temperature has exceeded set temperature by +40°F (+22°C), or an absolute maximum of 410°F (210°C). The alarm will also sound. This display does not show the status of the mechanical high limit switch.

This message indicates that the drain valve has been opened, the vat is assumed to be empty by the controller. Normal heat control activities are suspended. Display will show an alternating message [DRAINING] / [TURN OFF]. To restore to normal operation, close the drain value. Display will show [TURN OFF].

Turn controller off, and refill the vat. Continue with normal operations at section 1.

This message indicates that the heating system failed to respond. Typically, the high temperature limit switch has tripped and is in need of resetting. In the case on gas fired appliances, this message will display if the pilot fails to light or is detected marginal by the ignition module. Display will show an alternating message [HEAT] / [FAILURE].

This message indicates a shorted probe. If probe is detected as a short circuit, normal heating and cooking activities are suspended. Display will show an alternating message

[SYSTEM] / [FAILURE].

This message indicates that a recoverable system error has occurred. Press ‘6’ for YES to perform a factory reset or ‘0’ for NO to return to OFF. Normal use of the system will only resume when a factory reset has been performed. Display will show an alternating message [FACTORY] / [RESET].

Page 23 of 28

L22-355 Rev 1

Image 23
Contents Important Information for Future Reference For Pitco P/N 60149505 Spin FryerTo Enter Programming Level 1 for the Store Manager Spin Fryer I12 Cooking Computer To start a cook To turn the appliance onTo turn the appliance OFF To check Actual and Set temperatures To cancel a cookManual Boil Entry To perform a Boil Out operationAutomatic Boil Entry Water Detection To Enter Programming Level 1 for the Store Manager To Set Cook TemperatureHold Time Cook TimeShake Time To Exit Level 1 programming Hold Pre-AlarmSpin Time Spin RateFahrenheit or Celsius Display Password Change or Required?To Change Options Level 2 for the Store Manager Melt Cycle Type Beeper ON/OFFLanguage Selection Recovery Test Value Melt Cycle on Time Offset the Temperature DisplayTo Enter Programming Level 3 for the Technician Minimum on and OFF Cycle Time Recovery TimesFunction Description Button Diagnostic Menu EntryInstant On Toggle Temperature Operating RangeMore Service Menu Entry Ready LevelConfiguration Value Shake Alarm DurationHold Alarm Duration Cancel DurationTo Exit Programming Level Factory ResetStanding Pilot Toggle Set Network AddressPitco Collect toggle Offset Temperature DisplayFactory Menu Level 4 for the Technician High Limit Value Recovery Test ValuesOperating Temperature Range Used if object becomes stuck during spinning Spin DiagnosticsTo Exit Factory Menu Level Test On/OffMore Factory Menu Entry 12.1 Control ID DisplaySystem / Failure Other DisplaysPage Mechanical Dimensions J1Left Inputs Type Nominal Electrical Connections at Left and Right connectorsProbe Resistance Probe Resistance ChartProbe Resistance in 5F Increments OhmsMailing Address P.O. BOX 501, CONCORD, NH