Pitco Frialator 20, 26 manual Initial Adjustments, Visual Checks, Burner Ignition Systems

Page 17

1.5INITIAL ADJUSTMENTS

After your fryer has been installed as described in section 1.4, it needs to be adjusted to ensure that it will perform as designed. These adjustments must be performed by a qualified person. To perform these adjustment the following tools will be needed:

• Manometer (low pressure gauge)

• Digital Thermometer (Temperature probe)

• DC Millivolt Meter

 

1.5.1 Visual Checks

 

Before you begin filling and adjusting the fryer, perform the following visual checks:

a.After the fryer is in its permanent location check the level- ness. Any additional leveling that is necessary can be performed as described in section 1.3.

b.Check the temperature bulb (high-limit), located in the fryer tank to ensure that the mounting screws are tight. The figure shows the probe location. Look down inside the fryer tanks to see the probes.

Ensure that these parts

are not loose.

1.5.2Burner Ignition Systems

CAUTION

Before going any further, fill the fryer with WATER. Water is used for the installation adjustments because the temperature will never exceed 212°F (100°C) thereby allowing plenty of adjustment time. Never let the water level go below the MIN LEVEL mark on the rear of the tank.

WARNING

There is an open flame inside the fryer. The unit may get hot enough to set near by materials on fire. Keep the area around the fryer free from combus- tibles.

1-8

Image 17
Contents TheresAlwaysSomethingCooking Page For Your Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety Table of Contents Section Title Operating Instructions Owner Maintenance and AdjustmentsList of Tables and Figures Page Which Fryer do I HAVE? General Information and InstallationChecking Your NEW Fryer Assembly and LevelingLeg Installation and Adjustment Splashback Installation Heat Deflector InstallationFlue Installation Drainboard InstallationGas Connection InstallationInstallation Clearances Page Electrical Connection Ventilation and Fire Safety SystemsANSI/UL Burner Ignition Systems Initial AdjustmentsVisual Checks OFF Page Page Insufficient Flow Main Burner SystemExcessive Flow Insufficient GAS Pressure Normal FlowPage Initial Cleaning Thermostat Calibration Check Standard Thermostat Calibration Solid State Thermostat CalibrationPage Page Filling the Fryer Operating InstructionsFilling the Fryer With Liquid Shortening Filling the Fryer With Solid ShorteningFryer Start-Up Operating InstructionsDo not Start Fryer Without Filling with OIL Fryer Shut-DownDaily Cleaning Power FailurePage Weekly Fryer Cleaning Boil OUT Owner Maintenance and AdjustmentsPage Fryer does not work Fryer Troubleshooting