1.5.2.1Lighting Instructions for Manual Pilot Lights - To light the pilot light refer to the following instructions.
WARNING
Wait 5 minutes before attempting to relight the pilot to allow for any gas in the fryer to dissipate.
a.Open the gas supply valves to the fryer.
b.Turn the thermostat control knob counterclockwise to the OFF position.
c.Turn the gas valve knob to the PILOT position and push in on the knob. Hold the knob in for approximately one minute to purge the air out of the line. Hold a flame to the pilot light until the pilot ignites. This may take a little while the first time you light the fryer because of air in the lines. Once lit, hold the knob in for approximately 60 seconds and then release.
ON
OFF |
|
P | |
I | |
L | |
T | O |
d.If the pilot goes out wait 5 minutes and repeat step c. If after three tries the pilot will not remain lit, refer to the operator troubleshooting section of this manual.
e.Turn the gas valve knob counterclockwise to the ON position.
f.Set the thermostat control knob to the desired temperature setting.
|
| O | |
| L | T | |
P | I |
|
|
|
|
| |
OFF |
|
|
ON
g.The main burner will light and be controlled by the thermostat.
1.5.2.1.1Pilot Flame Adjustment - The pilot flame should be adjusted to produce the proper millivolt output from the pilot sensing device. Millivolt output for the thermopile should be between 300 and 500 millivolts. This procedure is only necessary on the manual pilot ignition system. Figure