Pitco Frialator 26, 20 manual Fryer Troubleshooting, Fryer does not work

Page 34

3.2FRYER TROUBLESHOOTING

Refer to this section to correct common problems that may be encountered in equipment operation.

Fryer does not work.

Will the

NO

 

pilot light?

 

YES

Does pilot

remain lit after NO Unitrol Knob is

released?

 

 

 

 

 

Is the gas

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

valve open?

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Purge air from gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

line (1.5.2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is all the air

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

purged from the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gas line?

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

Open the gas valve and light pilot (1.5.2)

Is High Limit

YES

 

Switch open?

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

Contact a

 

 

 

Will Limit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Qualified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switch reset?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technician.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

YES

 

Purge air from gas line by

 

 

 

 

 

 

placing the Unitrol Valve

 

 

knob in PILOT and holding

 

 

 

in for approx. 1 minute.

 

 

 

 

 

Contact a

Qualified

Technician.

Reset & Light Pilot

Does pilot

go out when the YES temperature increases?

NO

Contact a Qualified

Technician.

Does the Main

NO

 

burner light?

 

YES

If the main burner is lighting but not performing properly refer to Chapter 1 to verify proper installation or contact a qualified technician.

 

Is the Unitrol gas

 

 

YES

 

 

 

 

 

 

valve knob in the ON

 

 

 

 

 

 

 

 

 

 

 

 

position?

 

 

 

NO

Turn Unitrol gas knob to ON.

 

 

 

Is the

 

 

 

 

NO

 

 

 

 

 

 

 

Thermostat

 

 

 

 

Contact a Qualified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

knob in the OFF

 

 

 

 

 

Technician.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Turn Thermostat to a temperature setting.

3-3

Image 34
Contents TheresAlwaysSomethingCooking Page For Your Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety Table of Contents Owner Maintenance and Adjustments Section Title Operating InstructionsList of Tables and Figures Page General Information and Installation Which Fryer do I HAVE?Leg Installation and Adjustment Assembly and LevelingChecking Your NEW Fryer Flue Installation Heat Deflector InstallationSplashback Installation Drainboard InstallationInstallation Clearances InstallationGas Connection Page Ventilation and Fire Safety Systems Electrical ConnectionANSI/UL Visual Checks Initial AdjustmentsBurner Ignition Systems OFF Page Page Excessive Flow Main Burner SystemInsufficient Flow Insufficient GAS Pressure Normal FlowPage Initial Cleaning Thermostat Calibration Check Standard Thermostat Calibration Thermostat Calibration Solid StatePage Page Filling the Fryer With Liquid Shortening Operating InstructionsFilling the Fryer Filling the Fryer With Solid ShorteningDo not Start Fryer Without Filling with OIL Operating InstructionsFryer Start-Up Fryer Shut-DownPower Failure Daily CleaningPage Owner Maintenance and Adjustments Weekly Fryer Cleaning Boil OUTPage Fryer Troubleshooting Fryer does not work