c.Turn the gas valve knob to the ON position.

d.Turn the fryer ON/OFF/TEST switch to the ON position. If the fryer is equipped with the optional melt cycle, place the switch in the MELT ON position.

e.Turn the thermostat to the desired temperature setting.

f.The main burner will light and be controlled by the thermostat.

g.The POWER ON light will come on and remain on as long as the power switch is in the ON position. The HEATING light will be lit when the main burners are on.

1.5.2.2.1Electronic Ignition Pilot Flame Adjustment - Figure 1-3 illustrates the pilot adjusting screw location

a.This test requires that a DC milliammeter be connected between the flame sensor terminal and the flame sensor lead. Observe correct polarity, if the meter needle goes below 0 milliamps reverse the leads. The current reading must be 0.15 milliamps or greater.

b.Adjust the current reading to the required level by adjusting the pilot flame. Remove the pilot flame adjustment cover to expose the adjusting screw.

c.Turning the flame adjusting screw clockwise lowers the flame and current. Turning the screw counterclockwise increases flame size and current.

d.Rotate the screw in the direction to achieve a reading of 0.15 mA or greater.

NOTICE

Allow 3 to 5 minutes between flame adjustments to allow the reading to settle.

e.Once the pilot flame is set, replace the pilot flame adjusting screw cover and remove the ammeter.

1-11

Image 20
Contents TheresAlwaysSomethingCooking Page For Your Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety Table of Contents Owner Maintenance and Adjustments Section Title Operating InstructionsList of Tables and Figures Page General Information and Installation Which Fryer do I HAVE?Checking Your NEW Fryer Assembly and LevelingLeg Installation and Adjustment Heat Deflector Installation Splashback InstallationFlue Installation Drainboard InstallationGas Connection InstallationInstallation Clearances Page Ventilation and Fire Safety Systems Electrical ConnectionANSI/UL Burner Ignition Systems Initial AdjustmentsVisual Checks OFF Page Page Main Burner System Insufficient FlowExcessive Flow Insufficient GAS Pressure Normal FlowPage Initial Cleaning Thermostat Calibration Check Standard Thermostat Calibration Thermostat Calibration Solid StatePage Page Operating Instructions Filling the FryerFilling the Fryer With Liquid Shortening Filling the Fryer With Solid ShorteningOperating Instructions Fryer Start-UpDo not Start Fryer Without Filling with OIL Fryer Shut-DownPower Failure Daily CleaningPage Owner Maintenance and Adjustments Weekly Fryer Cleaning Boil OUTPage Fryer Troubleshooting Fryer does not work