Pitco Frialator 26, 20 manual

Page 26

c.Let the fryer cycle 4 to 6 times to ensure that the temperature has stabilized. Compare the thermometer temperature against the thermostat setting. If the values are more than 5°F apart, go to step d. If the values are within 5°F, the thermostat is operating correctly.

d.Loosen the set screw that holds the thermostat knob to its shaft.

e.Rotate the thermostat dial, without moving the shaft, to the temperature indicated on the thermometer. Tighten the set screw on the thermostat dial to lock the dial in place.

f.Adjust the thermostat to a new setting and allow the fryer to cycle 4 to 6 times at the new setting. Check the thermometer temperature against the dial setting. If the temperature is ±5°F of the thermostat dial setting, remove the thermometer and replace the tube screen. If the temperature is greater than ±5°F away from the dial setting, perform the above procedure again.

1-17

Image 26
Contents TheresAlwaysSomethingCooking Page For Your Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety Table of Contents Owner Maintenance and Adjustments Section Title Operating InstructionsList of Tables and Figures Page General Information and Installation Which Fryer do I HAVE?Checking Your NEW Fryer Assembly and LevelingLeg Installation and Adjustment Flue Installation Heat Deflector InstallationSplashback Installation Drainboard InstallationGas Connection InstallationInstallation Clearances Page Ventilation and Fire Safety Systems Electrical ConnectionANSI/UL Burner Ignition Systems Initial AdjustmentsVisual Checks OFF Page Page Excessive Flow Main Burner SystemInsufficient Flow Insufficient GAS Pressure Normal FlowPage Initial Cleaning Thermostat Calibration Check Standard Thermostat Calibration Thermostat Calibration Solid StatePage Page Filling the Fryer With Liquid Shortening Operating InstructionsFilling the Fryer Filling the Fryer With Solid ShorteningDo not Start Fryer Without Filling with OIL Operating InstructionsFryer Start-Up Fryer Shut-DownPower Failure Daily CleaningPage Owner Maintenance and Adjustments Weekly Fryer Cleaning Boil OUTPage Fryer Troubleshooting Fryer does not work