❑CONNECT THE WHGE TO GX (continued)
1.Install a manual gas line
2.Install male 1/2” flare union adapter to the 1/2” NPT internal thread elbow at inlet of regulator. On models equipped titi standard tin burners, install the male pipe thread end of the 1/2” flare union adapter to the 1/2” N~ internal thread at inlet of pressure regulator. Use a backup wrench on the regulator fitting to avoid damage.
men installing the range from the front, remove the 90° elbow for easier installation.
3.Install male 1/2” or 3/4” flare union adapter to the NPT internal thread of the manual shut- off valve, taking care to
4.Connect flexible metal appliance connector to the adapter on the range. Position range to permit connection at the
5.men all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system.
CA~ON: DO NOT USE A FME TO CHECK FOR GAS ~.
men using test pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual
❑ELECTRIUL CONNECTIONS (on some models)
Electrical Requirement
12@volt, 60 Hertz, properly grounded branch circuit protected by a
Extension Cord Cautions
Because of potential safety huards associated with certain conditions, we strongly recommend against the use of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a
Grounding
IMPORTANT-(Please read carefilly)
FOR PERSONAL SAFETY, THIS APPL~CE MUST BE PROPEWY GROUNDED.
The power cord of this appliance is equipped with a
|
| wall receptacle | |
PREFERRED | , | to minimize the | |
METHOD |
| possibility of | |
| @Q | electric shock | |
o | hazard from | ||
G | |||
| <, | this appliance. | |
|
| ||
| n The customer | ||
| Ensure proper | should have the | |
| ground exists | wall receptacle | |
| before use | and circuit | |
QF | checked by a | ||
|
|
qualified electrician to make sure the receptacle is properly grounded.
mere a standard
DO NOT, UNDER W CIRCUMSTANCES, CUT OR REMO~ THE THIRD (GROUND) PRONG FROM THE PO~R CORD.
(continued next page)
39