Multiquip operation manual DCA-70SSJU- Rules for Safe Operation, Towing Safety Precautions

Page 13

DCA-70SSJU— RULES FOR SAFE OPERATION

Towing Safety Precautions

CAUTION:

Conform to Department of Transportation (DOT) Safety Towing Regulations before towing generator.

To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.

The following list of suggestions should be used when towing your generator:

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer "gross vehicle weight rating" (GVWR) of 6,000 lbs.

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a "Safety Chain".

ALWAYS attach trailer’s safety chains to towing vehicle properly.

ALWAYS make sure the vehicle and trailer directional, backup, brake, and trailer lights are connected and working properly.

The maximum speed for highway towing is 45 MPH unless posted otherwise. Recommended off-road towing is not to exceed 10 MPH or less depending on type of terrain.

Place chock blocks underneath wheel to prevent rolling, while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

Avoid sudden stops and starts. This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when transporting.

DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest and first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

DCA-70SSJU SERIES — OPERATION AND PARTS MANUAL (STD)— REV. #5 (06/03/03) — PAGE 13

Image 13
Contents MQ Power DCA-70SSJU Whisperwatttm Generator Page Heres HOW to GET Help Table of Contents Fax Parts Ordering ProceduresDCA-70SSJU Series Specifications Dimensions DCA-70SSJU Series Dimensions TOP, Side and FrontDo not follow directions DCA70SSJU Safety Message Alert SymbolsAlways wear approved eye and hearing protection DCA70SSJU Safety Message Alert SymbolsDCA-70SSJU Series Rules for Safe Operation General SafetyRadiator DCA-70SSJU Series Rules for Safe OperationAlways store equipment properly when not in use BatteryDCA-70SSJU- Rules for Safe Operation TransportingDCA-70SSJU- Rules for Safe Operation Towing Safety PrecautionsTypical Generator Grounding Application DCA-70SSJU- InstallationWhenever an engine is installed indoors the exhaust fumes Outdoor InstallationMounting Generator with Trailer DCA-70SSJU Series -TOWING Safety PrecautionsExplanation of Chart DCA-70SSJU Series -TRAILER SpecificationsTrailer Specifications DCA-70SSJU Series -TRAILER SpecificationsSpecifications DCA-70SSJU Series Generator Decals DCA-70SSJU Series Generator Decals DCA-70SSJU Series General Information Generator Major Components DCA-70SSJU Series Major ComponentsRelay monitors the current DCA-70SSJU Series Generator Control PanelTerminals to the load Amp breakerFuel Gauge Indicates amount of diesel fuel available DCA-70SSJU Series Engine Operating PanelEngine Operating Panel From S/N 73002141~ DCA-70SSJU Series Engine Operating PanelDCA-70SSJU Series Engine Operating Panel Output Terminal Familiarization DCA-70SSJU Series Output Terminal Panel Familiarization Two 2 Gfci Circuit Breakers 120V@ 20 amps Removing the Plastic Face Plate Uvwo Terminals 120VAC Gfci ReceptaclesOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadDCA-70SSJU Series Load Application If wattage is not given on the equipments name plateVoltage Selector Switch Locking Button Voltage Selector SwitchDCA-70SSJU Series Generator Outputs Generator OutputVoltagesDCA-70SSJU Series Generator OUTPUTS/GAUGE Reading How to Read the Output Terminal GaugeGfci Receptacle Load Capability Uvwo Terminal Output Voltages DCA-70SSJU Series Output Terminal Panel Connections3Ø 240/139 Uvwo Terminal Output Voltages 3Ø 208V/1Ø120V Uvwo Terminal Output Voltages1Ø 240V/120V Uvwo Terminal Output Voltages 3Ø 480/277 Uvwo Terminal Output VoltagesCircuit Breakers DCA-70SSJU Series PRE-SETUPLubrication Oil Fuel CheckRefueling Procedure DCA-70SSJU Series PRE-SETUPRefueling Full Trailer Tank Air Cleaner Fan Belt Tension Cleaning the RadiatorOperation Freezing Weather Must be less than 50%When connecting battery do the following Battery Cable InstallationWiring AlternatorBefore Starting DCA-70SSJU Series Generator START-UP Procedure ManualClose all engine enclosure doors Figure Engine Operating Panel S/N 73002140 and belowCold Starting Button Engine Operating Panel up to S/NCoolant Temperature Gauge Engine Operating Panel S/N 73002141~ Set engine speed switch to LOW FigurePlace the Off/Manual/Auto switch in the Auto position DCA-70SSJU Series Generator START-UP Procedure Auto ModeShutdown Procedure Ignition Switch Up to S/N DCA-70SSJU Series Generator SHUT-DOWN ProcedureShutdown Procedure Engine Controller S/N 73002141~ Emergency Shutdown Procedure Ignition Switch Up to S/NDCA-70SSJU Series Maintenance Feed Pump Strainer Cleaning Cleaning the Fuel StrainerAir Removal Check Oil LevelDCA-70SSJU Series Maintenance Brake Adjustment DCA-70SSJU Series -TRAILER Brakes MaintenanceBrakes Hydraulic Surge BrakesTires/Wheels/Lug Nuts DCA-70SSJU Series -TRAILER MaintenanceTire Wear/Inflation SuspensionStart all wheel lug nuts by hand Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram DCA-70SSJU Series -TRAILERWIRING DiagramGenerator Wiring Diagram DCA-70SSJU Series Generatorwiring DiagramEngine Wiring Diagram Controller DCA-70SSJU Series Enginewiring Diagram with ControllerDCA-70SSJU Series Engine Wiring Diagram with Ignition Switch Engine does not start DCA-70SSJU Series -TROUBLESHOOTING EngineStarter does not run DCA-70SSJU Series -TROUBLESHOOTING Engine Generator Troubleshooting DCA-70SSJU Series -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-70SSJU Series -TROUBLESHOOTING Engine ControllerPage Items Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description DCA-70SSJU Series Suggested Spare PartsDCA-70SSJU Series Nameplate and Decals STRIPE, Whisperwatt STRIPE, MQ PowerStripe DCA-70SSJU Series Generator Assy Include Items W Generator AssyField Assy FANDCA-70SSJU Series Control BOX Assy Control BOX Assy Switch CoverMachine Screw NTA-5A-2DBDCA-70SSJU Series Control BOX ASSY. REOSTAT,VOLTAGE Regulator SL-2VSKnob ST0PPERDCA-70SSJU Series Engine and Radiator Assy Engine Foot DCA-70SSJU Series Engine and Radiator ASSY. DCA-70SSJU Series Engine and Radiator ASSY. DCA-70SSJU Series Engine and Radiator ASSY. N7301311~ M22606000240602202597 0602220621N7300001TO S/N7302140 N73002141~ DCA-70SSJU Series Engine Operating Panel Assy0605804150 0601840190031108160 0605010550DCA-70SSJU Series Engine Operating Panel ASSY. Panel Light N7300061TO S/N7302140 DCA-70SSJU Series Outputterminal AssyHinge DCA-70SSJU Series Outputterminal ASSY. Cushion Rubber Breaker Fitting CoverStay Rubber NUTDCA-70SSJU Series Battery Assy Battery Bolt SET Battery BandBattery Cable Make LocallyN7300001TO S/N7300800 DCA-70SSJU Series Muffler AssyDCA-70SSJU Series Muffler Assy DCA-70SSJU Series Fueltank Assy CAP, Fueltank Fuel TankTank Band Supporter SheetEnclosure Assy DCA-70SSJU Series Enclosure AssyCOVER, Front Frame Under CoverAcoustic Sheet Center FrameEnclosure ASSY. DCA-70SSJU Series Enclosure ASSY.Washer DCA-70SSJU Series Enclosure ASSY. Duct Side DoorDoor Stopper EmblemDCA-70SSJU Series Rubber Seal Assy 0229200825 02289015800228900670 0228901090Terms and Conditions of Sale Parts Page Heres HOW to GET Help