Multiquip operation manual DCA-70SSJU Series Rules for Safe Operation, Radiator

Page 11
NEVER grab or touch a live power cord with
wet hands , the POWER
CORD
possibility exists (POWER ON)
of electrical shock, electrocution, and even death!
WET
HANDS

DCA-70SSJU SERIES — RULES FOR SAFE OPERATION

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and local codes before operating generator.Severe injury or death! by electrocution can result from operating an ungrounded generator.

ALWAYS be sure the operator is familiar with proper safety precautions and operations techniques before using generator.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

ALWAYS read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

.

DANGER:

Backfeed to a utility system can cause electrocution and or property damage. DO NOT connect to any building's electrical system except through an approved device or after building main switch is opened. ALWAYS have a licensed electrician perform the installation

DANGER:

CAUTION:

Never use damaged or worn cables when connecting equipment to the generator. Make sure power

c o n n e c t i n g cables are securely connected to the

Radiator

DO NOT touch or open any of the below mentioned components while the generator is running. Always allow sufficient time for the engine and generator to cool before performing maintenance.

generator’s output terminals, insufficient tightening of the terminal connections may cause damage to the generator and electrical shock.

DANGER:

1.Radiator Cap - Removing the radiator cap while the engine is hot will result in high pressurized, boiling water to gush out of the radiator, causing severe scalding to any persons in the general area of the generator.

2.Coolant Drain Plug - Removing the coolant drain plug while the engine is hot will result in hot coolant to gush out of the coolant drain plug, therefore causing severe scalding to any persons in the general area of the generator.

3.Engine Oil Drain Plug - Removing the engine oil drain plug while the engine is hot will result in hot oil to gush out of the oil drain plug, therefore causing severe scalding to any persons in the general area of the generator.

DANGER:

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

NEVER touch output terminals during operation. This is extremely dangerous. ALWAYS stop the machine and place the circuit breaker in the “OFF” position when contact with the output terminals is required. There exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even death!

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

DCA-70SSJU SERIES — OPERATION AND PARTS MANUAL (STD)— REV. #5 (06/03/03) — PAGE 11

Image 11
Contents MQ Power DCA-70SSJU Whisperwatttm Generator Page Heres HOW to GET Help Table of Contents Fax Parts Ordering ProceduresDCA-70SSJU Series Specifications Dimensions DCA-70SSJU Series Dimensions TOP, Side and FrontDo not follow directions DCA70SSJU Safety Message Alert SymbolsAlways wear approved eye and hearing protection DCA70SSJU Safety Message Alert SymbolsDCA-70SSJU Series Rules for Safe Operation General SafetyRadiator DCA-70SSJU Series Rules for Safe OperationTransporting BatteryAlways store equipment properly when not in use DCA-70SSJU- Rules for Safe OperationDCA-70SSJU- Rules for Safe Operation Towing Safety PrecautionsTypical Generator Grounding Application DCA-70SSJU- InstallationMounting Outdoor InstallationWhenever an engine is installed indoors the exhaust fumes Generator with Trailer DCA-70SSJU Series -TOWING Safety PrecautionsExplanation of Chart DCA-70SSJU Series -TRAILER SpecificationsTrailer Specifications DCA-70SSJU Series -TRAILER SpecificationsSpecifications DCA-70SSJU Series Generator Decals DCA-70SSJU Series Generator Decals DCA-70SSJU Series General Information Generator Major Components DCA-70SSJU Series Major ComponentsAmp breaker DCA-70SSJU Series Generator Control PanelRelay monitors the current Terminals to the loadFuel Gauge Indicates amount of diesel fuel available DCA-70SSJU Series Engine Operating PanelEngine Operating Panel From S/N 73002141~ DCA-70SSJU Series Engine Operating PanelDCA-70SSJU Series Engine Operating Panel  Two 2 Gfci Circuit Breakers 120V@ 20 amps DCA-70SSJU Series Output Terminal Panel FamiliarizationOutput Terminal Familiarization Removing the Plastic Face Plate Uvwo Terminals 120VAC Gfci ReceptaclesOver Current Relay Connecting LoadsIf wattage is not given on the equipments name plate Single Phase LoadThree Phase Load DCA-70SSJU Series Load ApplicationGenerator OutputVoltages Voltage Selector SwitchVoltage Selector Switch Locking Button DCA-70SSJU Series Generator OutputsGfci Receptacle Load Capability How to Read the Output Terminal GaugeDCA-70SSJU Series Generator OUTPUTS/GAUGE Reading 3Ø 208V/1Ø120V Uvwo Terminal Output Voltages DCA-70SSJU Series Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø 240/139 Uvwo Terminal Output Voltages1Ø 240V/120V Uvwo Terminal Output Voltages 3Ø 480/277 Uvwo Terminal Output VoltagesFuel Check DCA-70SSJU Series PRE-SETUPCircuit Breakers Lubrication OilRefueling DCA-70SSJU Series PRE-SETUPRefueling Procedure Full Trailer Tank Must be less than 50% Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation Freezing WeatherAlternator Battery Cable InstallationWhen connecting battery do the following WiringEngine Operating Panel S/N 73002140 and below DCA-70SSJU Series Generator START-UP Procedure ManualBefore Starting Close all engine enclosure doors FigureCold Starting Button Engine Operating Panel up to S/NCoolant Temperature Gauge Engine Operating Panel S/N 73002141~ Set engine speed switch to LOW FigurePlace the Off/Manual/Auto switch in the Auto position DCA-70SSJU Series Generator START-UP Procedure Auto ModeEmergency Shutdown Procedure Ignition Switch Up to S/N DCA-70SSJU Series Generator SHUT-DOWN ProcedureShutdown Procedure Ignition Switch Up to S/N Shutdown Procedure Engine Controller S/N 73002141~DCA-70SSJU Series Maintenance Check Oil Level Cleaning the Fuel StrainerFeed Pump Strainer Cleaning Air RemovalDCA-70SSJU Series Maintenance Hydraulic Surge Brakes DCA-70SSJU Series -TRAILER Brakes MaintenanceBrake Adjustment BrakesSuspension DCA-70SSJU Series -TRAILER MaintenanceTires/Wheels/Lug Nuts Tire Wear/InflationStart all wheel lug nuts by hand Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram DCA-70SSJU Series -TRAILERWIRING DiagramGenerator Wiring Diagram DCA-70SSJU Series Generatorwiring DiagramEngine Wiring Diagram Controller DCA-70SSJU Series Enginewiring Diagram with ControllerDCA-70SSJU Series Engine Wiring Diagram with Ignition Switch Starter does not run DCA-70SSJU Series -TROUBLESHOOTING EngineEngine does not start DCA-70SSJU Series -TROUBLESHOOTING Engine Generator Troubleshooting DCA-70SSJU Series -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-70SSJU Series -TROUBLESHOOTING Engine ControllerPage Items Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description DCA-70SSJU Series Suggested Spare PartsDCA-70SSJU Series Nameplate and Decals Stripe STRIPE, MQ PowerSTRIPE, Whisperwatt DCA-70SSJU Series Generator Assy FAN Generator AssyInclude Items W Field AssyDCA-70SSJU Series Control BOX Assy NTA-5A-2DB Switch CoverControl BOX Assy Machine ScrewDCA-70SSJU Series Control BOX ASSY. ST0PPER SL-2VSREOSTAT,VOLTAGE Regulator KnobDCA-70SSJU Series Engine and Radiator Assy Engine Foot DCA-70SSJU Series Engine and Radiator ASSY. DCA-70SSJU Series Engine and Radiator ASSY. DCA-70SSJU Series Engine and Radiator ASSY. 0602220621 M2260600024N7301311~ 0602202597N7300001TO S/N7302140 N73002141~ DCA-70SSJU Series Engine Operating Panel Assy0605010550 06018401900605804150 031108160DCA-70SSJU Series Engine Operating Panel ASSY. Panel Light N7300061TO S/N7302140 DCA-70SSJU Series Outputterminal AssyHinge DCA-70SSJU Series Outputterminal ASSY. NUT Breaker Fitting CoverCushion Rubber Stay RubberDCA-70SSJU Series Battery Assy Make Locally Battery BandBattery Bolt SET Battery CableN7300001TO S/N7300800 DCA-70SSJU Series Muffler AssyDCA-70SSJU Series Muffler Assy DCA-70SSJU Series Fueltank Assy Supporter Sheet Fuel TankCAP, Fueltank Tank BandEnclosure Assy DCA-70SSJU Series Enclosure AssyCenter Frame Under CoverCOVER, Front Frame Acoustic SheetEnclosure ASSY. DCA-70SSJU Series Enclosure ASSY.Washer DCA-70SSJU Series Enclosure ASSY. Emblem Side DoorDuct Door StopperDCA-70SSJU Series Rubber Seal Assy 0228901090 02289015800229200825 0228900670Terms and Conditions of Sale Parts Page Heres HOW to GET Help